Observability enhancement by optimal PMU placement considering random power system outages

被引:42
|
作者
Aminifar F. [1 ]
Fotuhi-Firuzabad M. [1 ]
Shahidehpour M. [2 ]
Khodaei A. [2 ]
机构
[1] Electrical Engineering Department, Sharif University of Technology, Tehran
[2] Electrical and Computer Engineering Department, Illinois Institute of Technology, Chicago
基金
美国国家科学基金会;
关键词
Phasor measurement units; Probabilistic assessment; System observability analysis; Wide-area measurement;
D O I
10.1007/s12667-011-0025-x
中图分类号
学科分类号
摘要
This paper enhances the observability of power networks by taking into consideration random component outages. The architecture of wide-area measurement system (WAMS) is analyzed in order to identify components that would affect the network observability. An iterative framework is devised to calculate a bus index in power networks equipped with phasor measurement units (PMUs) and conventional measurements. The average of bus indices represents a system index which provides an overall insight on the power network observability. The system index is utilized as a criterion to distinguish among multiple optimal PMU placements. Conventional bus injection and line flow measurements and the effect of zero-injection buses are considered in the proposed model. The numerical analyses are carried out for the proposed model and the results are discussed in detail. © 2011 Springer-Verlag.
引用
收藏
页码:45 / 65
页数:20
相关论文
共 50 条
  • [31] Optimal PMU placement method for complete topological observability of power system under various contingencies
    Abiri, Ebrahim
    Rashidi, Farzan
    Niknam, Taher
    Salehi, Mohammad Reza
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 61 : 585 - 593
  • [32] Optimal PMU Placement for Complete Power System Observability under (P-1) Contingency
    Shrivastava, Divya Rishi
    Siddiqui, Shahbaz Ahmed
    Verma, Kusum
    2017 IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (IEEE WIECON-ECE 2017), 2017, : 129 - 132
  • [33] Optimal PMU Placement for Power System Dynamic State Estimation by Using Empirical Observability Gramian
    Qi, Junjian
    Sun, Kai
    Kang, Wei
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (04) : 2041 - 2054
  • [34] Optimal PMU Placement for Power System Restoration
    Golshani, Amir
    Sun, Wei
    Zhou, Qun
    2015 CLEMSON UNIVERSITY POWER SYSTEMS CONFERENCE (PSC), 2015,
  • [35] Observability Constrained GA Approach for Optimal PMU Placement considering Zero Injection Modeling
    Sushma, G. Chandana
    Jyothsna, T. R.
    2018 INTERNATIONAL CONFERENCE ON CONTROL, POWER, COMMUNICATION AND COMPUTING TECHNOLOGIES (ICCPCCT), 2018, : 174 - 178
  • [36] Optimal PMU placement for modeling power grid observability with mathematical programming methods
    Almunif, Anas
    Fan, Lingling
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (02)
  • [37] Optimal PMU Placement for T?rkiye 400 kV Interconnected Power System Observability with Dragonfly Algorithm
    Bozal, Beytullah
    Ozturk, Ali
    Tosun, Salih
    Hos, Bulent
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2023, 30 (03): : 733 - 741
  • [38] Optimal PMU Placement for Topological Observability of Power System: Robust Measurement Design in the Space of Phasor Variables
    Khokhlov, M. V.
    Obushevs, A.
    Oleinikova, I.
    Mutule, A.
    2016 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2016,
  • [39] PMU Placement for Maximum Observability of Power System under Different Contingencies
    Singh, Satyendra P.
    Thakur, Amit K.
    Singh, S. P.
    FIRST INTERNATIONAL CONFERENCE ON POWER ENGINEERING COMPUTING AND CONTROL (PECCON-2017 ), 2017, 117 : 893 - 900
  • [40] PMU Placement for Maximal Power System Observability Using Topology Transformation
    Bawayan, Haneen
    Younis, Mohamed
    2019 IEEE SUSTAINABILITY THROUGH ICT SUMMIT (STICT), 2019, : 1 - 7