Optimized magnetic bead-based immunoassay for automated detection of protein toxins

被引:0
|
作者
Deok-Ho Jung
Kyoungmi Min
Yongkwon Jeon
Wonhee Jang
Youngeun Kwon
机构
[1] Dongguk University,Departments of Biomedical Engineering
[2] Dongguk University,Departments of Life Science
来源
BioChip Journal | 2012年 / 6卷
关键词
Immunoassay; Magnetic bead; Autonomous detection; Toxins; Fluorescent tag;
D O I
暂无
中图分类号
学科分类号
摘要
Rapid, accurate, and autonomous analysis of bioagents in the environment is critical in protecting human health from natural and intentional environmental contamination with biological toxicants. We previously developed and tested an immunoassay protocol that can be utilized for automated and simultaneous detection of selected biological agents and toxins. We adopted an antibody-based approach for the detection of pathogens and/or toxins. The fluorescent eTags™ were used as reporter molecules and the immunoassay was modified for automated field-deployed detection of pathogens and/or toxins. The present study improved the limit of detection of this system to be suitable for the detection of environmental toxins. We tested different settings to optimize the assay protocol and successfully detected 10 ng/mL (or 100 fg) of an toxin analog, ovalbumin. The developed assay represents a notable improvement from currently available assays in terms of reduced time, increased sensitivity, and automation potential. Additionally, this assay can be easily modified, with the appropriate antibodies, to detect a wide range of proteins and infectious agents.
引用
收藏
页码:293 / 298
页数:5
相关论文
共 50 条
  • [41] Determination of parvovirus antibodies in canine serum using magnetic bead-based chemiluminescence immunoassay
    Chen, Cuicui
    Guo, Xiaoxiao
    Liang, Huankun
    Ning, Bo
    Li, Jiexing
    Zhong, Shuhai
    Liu, Xipan
    Li, Laiqing
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2019, 66 (04) : 586 - 590
  • [42] Fabrication of a high aspect ratio (HAR) micropillar filter for a magnetic bead-based immunoassay
    C. Ruffert
    Q. Ramadan
    M. A. M. Gijs
    Microsystem Technologies, 2014, 20 : 1869 - 1873
  • [43] Fabrication of a high aspect ratio (HAR) micropillar filter for a magnetic bead-based immunoassay
    Ruffert, C.
    Ramadan, Q.
    Gijs, M. A. M.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2014, 20 (10-11): : 1869 - 1873
  • [44] An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities
    Choi, JW
    Oh, KW
    Thomas, JH
    Heineman, WR
    Halsall, HB
    Nevin, JH
    Helmicki, AJ
    Henderson, HT
    Ahn, CH
    LAB ON A CHIP, 2002, 2 (01) : 27 - 30
  • [45] Magnetic bead-based sample preparation
    Lamberg, Arja
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2007, 27 (12): : 26 - 27
  • [46] A functionally dynamic microchamber with rapid mixing and reaction capabilities for magnetic bead-based immunoassay
    Do, J
    Ahn, CH
    Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 416 - 418
  • [47] Development of a multiplexed bead-based immunoassay for the simultaneous detection of antibodies to 17 pneumococcal proteins
    Shoma, S.
    Verkaik, N. J.
    de Vogel, C. P.
    Hermans, P. W. M.
    van Selm, S.
    Mitchell, T. J.
    van Roosmalen, M.
    Hossain, S.
    Rahman, M.
    Endtz, H. Ph.
    van Wamel, W. J. B.
    van Belkum, A.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2011, 30 (04) : 521 - 526
  • [48] Development of a multiplexed bead-based immunoassay for the simultaneous detection of antibodies to 17 pneumococcal proteins
    S. Shoma
    N. J. Verkaik
    C. P. de Vogel
    P. W. M. Hermans
    S. van Selm
    T. J. Mitchell
    M. van Roosmalen
    S. Hossain
    M. Rahman
    H. Ph. Endtz
    W. J. B. van Wamel
    A. van Belkum
    European Journal of Clinical Microbiology & Infectious Diseases, 2011, 30 : 521 - 526
  • [49] EThe development of a bead-based multiplex immunoassay for the detection of IgG antibodies to CMV and EBV
    Tcherniaeva, Irina
    den Hartog, Gerco
    Berbers, Guy
    van der Klis, Fiona
    JOURNAL OF IMMUNOLOGICAL METHODS, 2018, 462 : 1 - 8
  • [50] Micro volume rotating disk electrode (RDE) amperometric detection for a bead-based immunoassay
    Wijayawardhana, CA
    Halsall, HB
    Heineman, R
    ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) : 3 - 11