Mechanical behavior of plasma-sprayed pure and reinforced hydroxyapatite coatings on Ti6Al4V alloy

被引:0
|
作者
Gurbhinder Singh
机构
[1] Guru Kashi University,Mechanical Engineering Department
关键词
Hydroxyapatite; Wear; Electrochemical corrosion; Bio-implant coatings;
D O I
暂无
中图分类号
学科分类号
摘要
Hydroxyapatite coatings with secondary reinforcement have attracted the attention of the researchers of concerned field. Reinforcement like alumina and titania are used to make the HA coatings more wear resistant. It has been reported in the existing published literature that wear and corrosion are the main cause of the bio-implant failure. This paper deals with the abrasive wear and electrochemical corrosion behavior of as-sprayed and heat-treated pure and 10 wt% 80Al2O3-TiO2-reinforced hydroxyapatite coatings successfully deposited by atmospheric plasma spray technique. Simulated body fluid (SBF) was prepared in laboratory to be used in electrochemical corrosion testing. Samples were dipped in SBF before abrasive wear testing. The coatings were characterized by XRD and SEM-EDAX analysis. Post-coating heat treatment was carried out at 700 and 800 °C. It has been found that post-coating heat treatment at 700 °C has favorable impact on both corrosion and wear resistance of coatings along with hardness and crystallinity of the coatings.
引用
收藏
页码:85 / 96
页数:11
相关论文
共 50 条
  • [21] Recent trends towards improved plasma-sprayed advanced bioceramic coatings on Ti6Al4V implants
    Heimann, RB
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 1999, 30 (12) : 775 - 782
  • [22] Unlubricated gross slip fretting wear of metallic plasma-sprayed coatings for Ti6Al4V surfaces
    Hager, C. H., Jr.
    Sanders, J. H.
    Sharma, S.
    WEAR, 2008, 265 (3-4) : 439 - 451
  • [23] Characteristics of plasma-sprayed bioactive glass coatings on Ti-6Al-4V alloy: An in vitro study
    Lee, TM
    Chang, E
    Wang, BC
    Yang, CY
    SURFACE & COATINGS TECHNOLOGY, 1996, 79 (1-3): : 170 - 177
  • [24] In vitro stability of plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V implants under cyclic loading
    Zhang, CG
    Leng, Y
    Zhang, XD
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 50 (02): : 267 - 275
  • [25] Hot pressing of plasma-sprayed SiC fiber-reinforced Ti-6Al-4V alloy
    Valente, T
    Carassiti, F
    JOURNAL OF COMPOSITES TECHNOLOGY & RESEARCH, 1996, 18 (02): : 89 - 95
  • [26] Hot pressing of plasma-sprayed SiC fiber-reinforced Ti-6Al-4V alloy
    Valente, Teodoro
    Carassiti, Fabio
    Journal of Composites Technology and Research, 1996, 18 (02): : 89 - 95
  • [27] THE EFFECT OF A PLASMA-SPRAYED HYDROXYAPATITE COATING ON THE FATIGUE PROPERTIES OF TI-6AL-4V
    EVANS, SL
    GREGSON, PJ
    MATERIALS LETTERS, 1993, 16 (05) : 270 - 274
  • [28] Plasma nitriding behavior of Ti6Al4V orthopedic alloy
    Yildiz, F.
    Yetim, A. F.
    Alsaran, A.
    Celik, A.
    SURFACE & COATINGS TECHNOLOGY, 2008, 202 (11): : 2471 - 2476
  • [29] In vitro studies of plasma-sprayed hydroxyapatite/Ti-6Al-4V composite coatings in simulated body fluid (SBF)
    Gu, YW
    Khor, KA
    Cheang, P
    BIOMATERIALS, 2003, 24 (09) : 1603 - 1611
  • [30] Influence of residual stress on bonding strength and fracture of plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V substrate
    Yang, YC
    Chang, E
    BIOMATERIALS, 2001, 22 (13) : 1827 - 1836