Metal artifacts reduction in kV-CT images with polymetallic dentures and complex metals based on MV-CBCT images in radiotherapy

被引:0
|
作者
Xiaochen Ni
Zhonghua Shi
Xinmao Song
Tianci Tang
Shengwei Li
Zhenfeng Hou
Wei Zhang
Wei Fang Wang
Fu Chen
Ji Li
Gang Yang
Ruichen Li
Xiaoshen Wang
机构
[1] Fudan University,Department of Radiotherapy, Eye & ENT Hospital
[2] Shanghai United Imaging Healthcare Co.,undefined
[3] Ltd,undefined
[4] Fudan University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This paper proposes a metal artifact reduction method of using MV-CBCT images to correct metal artifacts in kV-CT images, especially for the complex metal artifacts caused by multi-metal interaction of patients with head and neck tumors. The different tissue regions are segmented in the MV-CBCT images to obtain template images and the metal region is segmented in the kV-CT images. Forward projection is performed to get sinogram of the template images, kV-CT images and metal region images. Artifact images can be reconstructed through those sonograms. Corrected images is generated by subtracting the artifact images from the original kV-CT images. After the first correction, the template images are generated again and brought into the previous step for iteration to get better correction result. CT data set of 7 patients are used in this study, compared with linear interpolation metal artifact (LIMAR) and normalized metal artifact reduction method, mean relative error of CT value is reduced by 50.5% and 63.3%, noise is reduced by 56.2% and 58.9%. The Identifiability Score of the tooth, upper/lower jaw, tongue, lips, masseter muscle and cavity in the corrected images by the proposed method have significantly improved (P < 0.05) than original images. The artifacts correction method proposed in this paper can effectively remove the metal artifacts in the images and greatly improve the CT value accuracy, especially in the case of multi-metal and complex metal implantation.
引用
收藏
相关论文
共 50 条
  • [31] Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm
    Fang-ling Zhang
    Ruo-cheng Li
    Xiao-ling Zhang
    Zhao-hui Zhang
    Ling Ma
    Lei Ding
    BMC Cancer, 21
  • [32] Ring Artifacts Reduction in Cone-Beam CT Images based on Independent Component Analysis
    Chen, Yen-Wei
    Duan, Guifang
    Fujita, Akinori
    Hirooka, Ken
    Ueno, Yoshihiro
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1687 - +
  • [33] Reduction of Intravenous Contrast Related Artifacts in CT-Based Attenuation Corrected PET Images
    Ay, M. R.
    Bidgholi, J. H.
    Ghafarian, P.
    Zaidi, H.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 513 - 516
  • [34] Artifacts Reduction Method for Phase-resolved Cone-Beam CT (CBCT) Images via a Prior-Guided CNN
    Zhi, Shaohua
    Duan, Jiayu
    Cai, Jianmei
    Mou, Xuanqin
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [35] Metal artifacts reduction using monochromatic images from spectral CT: Evaluation of pedicle screws in patients with scoliosis
    Wang, Yang
    Qian, Bangping
    Li, Baoxin
    Qin, Guochu
    Zhou, Zhengyang
    Qiu, Yong
    Sun, Xizhao
    Zhu, Bin
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : E360 - E366
  • [36] Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT?
    Nascimento, Eduarda Helena Leandro
    Gaeta-Araujo, Hugo
    Fontenele, Rocharles Cavalcante
    Oliveira-Santos, Nicolly
    Oliveira-Santos, Christiano
    Freitas, Deborah Queiroz
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (09) : 5281 - 5291
  • [37] Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT?
    Eduarda Helena Leandro Nascimento
    Hugo Gaêta-Araujo
    Rocharles Cavalcante Fontenele
    Nicolly Oliveira-Santos
    Christiano Oliveira-Santos
    Deborah Queiroz Freitas
    Clinical Oral Investigations, 2021, 25 : 5281 - 5291
  • [38] Convolutional neural network-based metal and streak artifacts reduction in dental CT images with sparse-view sampling scheme
    Kim, Seongjun
    Ahn, Junhyun
    Kim, Byeongjoon
    Kim, Chulhong
    Baek, Jongduk
    MEDICAL PHYSICS, 2022, 49 (09) : 6253 - 6277
  • [40] The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners
    Kennedy, John A.
    Israel, Ora
    Frenkel, Alex
    Bar-Shalom, Rachel
    Azhari, Haim
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (06) : 553 - 562