A numerical study on the performance evaluation of ventilation systems for indoor radon reduction

被引:0
|
作者
Ji Eun Lee
Hoon Chae Park
Hang Seok Choi
Seung Yeon Cho
Tae Young Jeong
Sung Cheoul Roh
机构
[1] Yonsei University,Department of Environmental Engineering
来源
Korean Journal of Chemical Engineering | 2016年 / 33卷
关键词
Computational Fluid Dynamics; Exhalation; Indoor Air; Radon; Ventilation;
D O I
暂无
中图分类号
学科分类号
摘要
Numerical simulations were conducted using computational fluid dynamics to evaluate the effect of ventilation conditions on radon (222Rn) reduction performance in a residential building. The results indicate that at the same ventilation rate, a mechanical ventilation system is more effective in reducing indoor radon than a natural ventilation system. For the same ventilation type, the indoor radon concentration decreases as the ventilation rate increases. When the air change per hour (ACH) was 1, the indoor radon concentration was maintained at less than 100 Bq/m3. However, when the ACH was lowered to 0.01, the average indoor radon concentration in several rooms exceeded 148 Bq/m3. The angle of the inflow air was found to affect the indoor air stream and consequently the distribution of the radon concentration. Even when the ACH was 1, the radon concentrations of some areas were higher than 100 Bq/m3 for inflow air angles of 5° and 175°.
引用
收藏
页码:782 / 794
页数:12
相关论文
共 50 条
  • [21] Numerical Evaluation of Thermal and Ventilation Performance of Combined Passive Chilled Beam-Displacement Ventilation Systems
    Shan, Wenyu
    Rim, Donghyun
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [22] Ventilation performance and indoor air quality in workstations under different supply air systems: A numerical approach
    Jiang, Z
    Haghighat, F
    Chen, Q
    INDOOR AND BUILT ENVIRONMENT, 1997, 6 (03) : 160 - 167
  • [23] Testing the Properties of Radon Barrier Materials and Home Ventilation to Mitigate Indoor Radon
    Portaro, Manuela
    Tuccimei, Paola
    Galli, Gianfranco
    Soligo, Michele
    Longoni, Cristina
    Vasquez, Dino
    ATMOSPHERE, 2023, 14 (01)
  • [24] VENTILATION INFLUENCE UPON INDOOR AIR RADON LEVEL
    田德源
    NuclearScienceandTechniques, 1995, (01) : 58 - 60
  • [25] Evaluation of the performance of indoor MIMO systems
    Tang, ZW
    Mohan, AS
    2003 6TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION AND EM THEORY, PROCEEDINGS, 2003, : 553 - 555
  • [26] EVALUATION OF ROOM AIR CLEANERS FOR THE REDUCTION OF EXPOSURE AND DOSE TO INDOOR RADON PROGENY
    HOPKE, PK
    JENSEN, B
    MONTASSIER, N
    WASIOLEK, P
    RADIATION PROTECTION DOSIMETRY, 1994, 56 (1-4) : 55 - 60
  • [27] Study on the evaluation of cross ventilation performance considering distribution of indoor airflow velocity: Evaluation of cross ventilation performance of the detached house with cross ventilation degree hours of inside area
    Akabayashi, Shin-Ichi
    Sakaguchi, Jun
    Hosono, Atsumi
    Sato, Hideki
    Kubo, Shunsuke
    Journal of Environmental Engineering, 2008, 73 (633) : 1261 - 1266
  • [28] Design of residential ventilation systems using performance-based evaluation of Indoor Air Quality: application to a Danish study case
    Baptiste, Poirier
    Jakub, Kolarik
    Gaelle, Guyot
    Woloszyn, Monika
    BUILDSIM NORDIC 2022, 2022, 362
  • [29] Impact of ventilation systems and energy savings in a building on the mechanisms governing the indoor radon activity concentration
    Collignan, Bernard
    Powaga, Emilie
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2019, 196 : 268 - 273
  • [30] A Study on Ventilation Systems for Removing Indoor House Dust
    Lu, Yang
    Yoshino, Hiroshi
    Takaki, Rie
    Kurihara, Genta
    Yonekura, Hiroshi
    Liu, Jing
    INTERNATIONAL JOURNAL OF VENTILATION, 2010, 9 (01) : 1 - 10