A numerical study on the performance evaluation of ventilation systems for indoor radon reduction

被引:0
|
作者
Ji Eun Lee
Hoon Chae Park
Hang Seok Choi
Seung Yeon Cho
Tae Young Jeong
Sung Cheoul Roh
机构
[1] Yonsei University,Department of Environmental Engineering
来源
Korean Journal of Chemical Engineering | 2016年 / 33卷
关键词
Computational Fluid Dynamics; Exhalation; Indoor Air; Radon; Ventilation;
D O I
暂无
中图分类号
学科分类号
摘要
Numerical simulations were conducted using computational fluid dynamics to evaluate the effect of ventilation conditions on radon (222Rn) reduction performance in a residential building. The results indicate that at the same ventilation rate, a mechanical ventilation system is more effective in reducing indoor radon than a natural ventilation system. For the same ventilation type, the indoor radon concentration decreases as the ventilation rate increases. When the air change per hour (ACH) was 1, the indoor radon concentration was maintained at less than 100 Bq/m3. However, when the ACH was lowered to 0.01, the average indoor radon concentration in several rooms exceeded 148 Bq/m3. The angle of the inflow air was found to affect the indoor air stream and consequently the distribution of the radon concentration. Even when the ACH was 1, the radon concentrations of some areas were higher than 100 Bq/m3 for inflow air angles of 5° and 175°.
引用
收藏
页码:782 / 794
页数:12
相关论文
共 50 条
  • [1] A numerical study on the performance evaluation of ventilation systems for indoor radon reduction
    Lee, Ji Eun
    Park, Hoon Chae
    Choi, Hang Seok
    Cho, Seung Yeon
    Jeong, Tae Young
    Roh, Sung Cheoul
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 33 (03) : 782 - 794
  • [2] An Environmental Evaluation of Ventilation Systems Aimed at Reducing Indoor Radon Concentration
    Felicioni, Licia
    Jiranek, Martin
    Vlasata, Barbora
    Lupisek, Antonin
    BUILDINGS, 2023, 13 (11)
  • [3] APPLICABILITY OF VENTILATION SYSTEMS FOR REDUCING THE INDOOR RADON CONCENTRATION
    Jiranek, Martin
    Kacmarikova, Veronika
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (02) : 202 - 208
  • [4] A STUDY OF INDOOR RADON WITH VENTILATION AND AIR-CONDITIONING
    Wang, Zhiyong
    Liu, Changrong
    Wang, Hanqing
    Liu, Zehua
    Kou, Guangxiao
    Zhou, Xinghuo
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 901 - 908
  • [5] REDUCTION OF INDOOR RADON CONCENTRATION IN A ROOM USING HEAT RECOVERY VENTILATION
    Krajcik, Matus
    Mahas, Nataliia
    Durec, Frantisek
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2023, 32 (04): : 468 - 478
  • [6] THE REDUCTION OF INDOOR AIR CONCENTRATIONS OF RADON DAUGHTERS WITHOUT THE USE OF VENTILATION
    JONASSEN, N
    MCLAUGHLIN, JP
    SCIENCE OF THE TOTAL ENVIRONMENT, 1985, 45 (OCT) : 485 - 492
  • [7] EVALUATION OF VENTILATION PERFORMANCE FOR INDOOR SPACE
    YAMAMOTO, T
    ENSOR, DS
    SPARKS, LE
    BUILDING AND ENVIRONMENT, 1994, 29 (03) : 291 - 296
  • [8] Influence of ventilation on indoor radon level
    Chao, CYH
    Tung, TCW
    Burnett, J
    BUILDING AND ENVIRONMENT, 1997, 32 (06) : 527 - 534
  • [9] Comparison of Indoor Radon Reduction Effects Based on Apartment Housing Ventilation Methods
    Choi, Jiwon
    Hong, Hyongjin
    Lee, Jeongsub
    Kim, Seonhong
    Kim, Gahyun
    Park, Boram
    Cho, Eun-Min
    Lee, Cheolmin
    ATMOSPHERE, 2022, 13 (02)
  • [10] Simulation of ventilation effects on indoor radon
    Akbari, Keramatollah
    Mahmoudi, Jafar
    Ghanbari, Mahdi
    MANAGEMENT OF ENVIRONMENTAL QUALITY, 2013, 24 (03) : 394 - 407