Direct Electrochemistry and Elctrocatalytic Activity of Hemoglobin at CdTe Nanoparticle/Nafion Film-modified Electrode
被引:0
|
作者:
Zhan Wang
论文数: 0引用数: 0
h-index: 0
机构:Huazhong University of Science and Technology,Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, College of Life Science and Technology
Zhan Wang
Qiao Xu
论文数: 0引用数: 0
h-index: 0
机构:Huazhong University of Science and Technology,Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, College of Life Science and Technology
Qiao Xu
Hai-Qiao Wang
论文数: 0引用数: 0
h-index: 0
机构:Huazhong University of Science and Technology,Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, College of Life Science and Technology
Hai-Qiao Wang
Zhao-Hui Yin
论文数: 0引用数: 0
h-index: 0
机构:Huazhong University of Science and Technology,Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, College of Life Science and Technology
Zhao-Hui Yin
Jiu-Hong Yu
论文数: 0引用数: 0
h-index: 0
机构:Huazhong University of Science and Technology,Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, College of Life Science and Technology
Jiu-Hong Yu
Yuan-Di Zhao
论文数: 0引用数: 0
h-index: 0
机构:Huazhong University of Science and Technology,Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, College of Life Science and Technology
Yuan-Di Zhao
机构:
[1] Huazhong University of Science and Technology,Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, College of Life Science and Technology
Water-soluble CdTe nanoparticles and hemoglobin (Hb) were immobilized on a glassy carbon (GC) electrode with Nafion. The direct electrochemistry of Hb on this surface was studied. The results indicated that CdTe nanoparticles could effectively promote the direct electron transfer of Hb at the interface of a electrode. The average surface coverage of Hb on the surface could be calculated as 2.63×10–9 mol/cm2, the heterogeneous electron transfer rate constant, k, was calculated as 0.068 s–1 and the transfer coefficient, α, was 0.59, further study indicated that immobilized Hb still kept its catalytic activity to H2O2 reduction. The apparent Michaelis–Menten constant was calculated to be 17.7 μM. It was also found that the modified electrode could be used as a sensor for H2O2; the linear range of detection was 5.0×10–6 – 4.5×10–5 M, with a detection limit of 8.4×10–7 M. The sensor exhibited high sensitivity, reproducibility and stability.