摘要
A complex of diagnostic equipment for studying impulse X-ray radiation from high-current discharge plasma is presented. The complex provides measurements within an X-ray energy range of 1–300 keV and has a dynamic range of 1012. The results of investigating the spectral characteristics of X rays from plasma that is generated in the “low-inductive vacuum spark” device are presented as functions of the discharge current for various electrode materials.
引用
收藏
页码:252 / 256
页数:4
相关论文
共 50 条
  • [31] SPECTRA OF TURBULENT FLUCTUATIONS OF PLASMA PARAMETERS IN A HIGH-CURRENT TOROIDAL DISCHARGE
    LARIONOV, MM
    RODICHKI.VA
    ROZHDEST.VV
    TIMONIN, AM
    NUCLEAR FUSION, 1969, S : 37 - +
  • [32] Optical studies of plasma inhomogeneities in a high-current pulsed magnetron discharge
    A. V. Kozyrev
    N. S. Sochugov
    K. V. Oskomov
    A. N. Zakharov
    A. N. Odivanova
    Plasma Physics Reports, 2011, 37 : 621 - 627
  • [33] STABILIZATION OF A PINCHED HIGH-CURRENT DISCHARGE BY MEANS OF A PLASMA JET.
    Voronich, V.B.
    Ogurtsova, N.N.
    Podmoshenskii, I.V.
    Rogovtsev, P.N.
    Soviet physics. Technical physics, 1980, 25 (05): : 608 - 611
  • [34] INVESTIGATION OF ELECTROMAGNETIC RADIATION FROM PLASMA OF LINEAR HIGH-CURRENT DISCHARGE
    SUPRUNENKO, VA
    SUKHOMLINOV, EA
    TOLOK, VT
    REVA, NI
    RUDNEY, NI
    BURCHENK.PY
    FAINBERG, YB
    VOLKOV, ED
    JOURNAL OF NUCLEAR ENERGY PART C-PLASMA PHYSICS ACCELERATORS THERMONUCLEAR RESEARCH, 1964, 6 (2PC): : 181 - &
  • [35] Optical studies of plasma inhomogeneities in a high-current pulsed magnetron discharge
    Kozyrev, A. V.
    Sochugov, N. S.
    Oskomov, K. V.
    Zakharov, A. N.
    Odivanova, A. N.
    PLASMA PHYSICS REPORTS, 2011, 37 (07) : 621 - 627
  • [36] LARGE-AMPLITUDE OSCILLATIONS OF SOFT X-RAYS IN A HIGH-CURRENT DENSITY PLASMA ON TPE-1RM15 REVERSED-FIELD PINCH
    SHIMADA, T
    YAGI, Y
    HATTORI, K
    HIRANO, Y
    HIROTA, I
    MAEJIMA, Y
    OGAWA, K
    SAITO, K
    SHIINA, S
    PLASMA PHYSICS AND CONTROLLED FUSION, 1994, 36 (03) : 561 - 572
  • [37] Industrial and chemical research with X-rays of high intensity and with soft X-rays
    Clark, GL
    Corrigan, KE
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1931, 23 : 815 - 820
  • [38] Spectral diagnosis of underwater microsecond high-current pulsed discharge plasma
    Shijie, Huang
    Yi, Liu
    Liuxia, Li
    Fuchang, Lin
    Chenqian, Zeng
    Ning, Yang
    Tianyu, Wang
    Hongbin, Liao
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2024, 57 (28)
  • [39] The High-Current Electron Gun with Plasma Anode Based on a Combined Discharge
    Kiziridi, P. P.
    Ozur, G. E.
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 607 - 610
  • [40] The possible role of X-rays during radiofrequency discharge plasma treatment of polymer films
    A. N. Ponomarev
    High Energy Chemistry, 2016, 50 : 476 - 477