Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom

被引:0
|
作者
Dominique Debrun
Fabienne Thérain
Long-Dang Nguyen
Christophe P. Léger
Jacco J. N. Visser
机构
[1] Centre Hospitalier Régional d’ Orléans (CHRO),Service de Médecine Nucléaire
[2] Centre Hospitalier Régional d’ Orléans (CHRQ),Service de Cardiologie
[3] Université d’ Orléans,Laboratoire d’ Electronique Signaux Images (LESI)
[4] University of Amsterdam,Academic Medical Centre, Department of Nuclear Medicine
来源
The International Journal of Cardiovascular Imaging | 2005年 / 21卷
关键词
dynamic cardiac phantom; quality control; myocardial gated SPECT; 3D–4D echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose: A dynamic cardiac phantom was used as a reference to compare volumes measured with gated SPECT and 4D echocardiography. Material and Methods: Gated SPECT data were acquired with a standard single-head gamma camera, and the volume reconstructions were carried out using the Mirage software by Segami. 4D echocardiography used a new prototype of rotating scan head to acquire ultrasound images during a cardiac cycle, used to reconstruct the volume deformations as a function of time. End-diastolic volume, end-systolic volume, and ejection fraction were measured using both gated SPECT and 4D echocardiography. Results: The results obtained showed a good correlation between volumes measured with the two modalities, but a slight overestimation of volumes with gated SPECT. The influence of filtering and pixel size parameters on the measured volumes was quantified for gated SPECT, in order to correct the overestimation. Conclusion: The agreement between gated SPECT (after correction) and 4D echocardiography confirmed the relevance of the comparisons. This study was an initial step before conducting clinical trials to compare exhaustively left ventricular volumes obtained with the two modalities.
引用
收藏
页码:239 / 247
页数:8
相关论文
共 50 条
  • [31] Phantom validation of 4D flow: independent validation of vortex ring volume quantification using planar laser-induced fluorescence
    Johannes Töger
    Sebastian L Bidhult
    Johan Revstedt
    Marcus Carlsson
    Håkan Arheden
    Einar Heiberg
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [32] Validation of 4D CT Image Reconstruction Using a 3D Lung Phantom
    Zheng, Y.
    Girbino, M.
    Oshinsky, R.
    Vroege, L.
    Jesseph, F.
    Lee, S.
    Yuan, J.
    Machtay, M.
    Sohn, J.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [33] QUALITY ASSURANCE IN 4D CT AND GATED RADIOTHERAPY USING A COMMERCIAL RESPIRATORY MOTION PHANTOM
    Block, A.
    Mewes, A.
    Noertersheuser, T.
    Bauer, R.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S449 - S449
  • [34] Study of the efficacy of respiratory gating in myocardial SPECT using the new 4D NCAT phantom
    Segars, WP
    Tsui, BMW
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1536 - 1539
  • [35] A validation study of aortic stroke volume using dynamic 4D color doppler:: An in vivo study
    Rusk, RA
    Mori, Y
    Li, XN
    Jones, M
    Irvine, M
    Mehwald, PS
    Kenny, A
    Sahn, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 440A - 441A
  • [36] A study of the effect of cardiac gating in myocardial SPECT using the 4D NCAT
    Lee, TS
    Segars, WP
    Tsui, BMW
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2681 - 2685
  • [37] Assessment of fetal ventricular volume by dynamic 3D/4D echocardiography in normal fetuses
    Hui, L
    Sahn, CS
    Niemann, PS
    Wyatt, S
    Sahn, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 243A - 243A
  • [38] CARDIAC REGIONAL STRAIN EVALUATION FOR HYPERTROPHIC CARDIOMYOPATHY USING 4D ECHOCARDIOGRAPHY
    Sahn, David J.
    Tam, Hannah
    Tam, Lydia
    Ashraf, Muhammad
    Zhu, Meihua
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 985 - 985
  • [39] Volume visualization of the heart using MRI 4D cardiac images
    Abrishami Moghaddam, H.
    Lerallut, J.F.
    Journal of Computing and Information Technology, 1998, 6 (02): : 215 - 228
  • [40] Validation of a Novel 3D Printed Contrast-Detail Phantom for Cardiac Nuclear Medicine
    Green, S.
    Grice, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E562 - E562