Hemodynamic parameters at rest predicting exercise capacity in patients supported with left ventricular assist device

被引:0
|
作者
Hirotoshi Kato
Togo Iwahana
Ryohei Ono
Sho Okada
Goro Matsumiya
Yoshio Kobayashi
机构
[1] Chiba University Graduate School of Medicine,Department of Cardiovascular Medicine
[2] Chiba University Graduate School of Medicine,Department of Cardiovascular Surgery
来源
关键词
Left ventricular assist device; Exercise capacity; Hemodynamic;
D O I
暂无
中图分类号
学科分类号
摘要
Left ventricular assist devices improve prognosis and quality of life, but exercise capacity remains limited in most patients after device implantation. Left ventricular assist device optimization through right heart catheterization reduces device-related complications. However, hemodynamic parameters associated with exercise capacity under optimized conditions. The aim of this study was to elucidate the predictors of exercise capacity from hemodynamic parameters at rest after left ventricular assist device optimization. We retrospectively reviewed 24 patients who underwent a ramp test with right heart catheterization, echocardiography and cardiopulmonary exercise testing more than 6 months after left ventricular assist device implantation. Pump speed was optimized to a lower setting that achieved right atrial pressure < 12 mmHg, pulmonary capillary wedge pressure < 18 mmHg, and cardiac index > 2.2 L/min/m2, then exercise capacity was assessed by cardiopulmonary exercise testing. After left ventricular assist device optimization, the mean right atrial pressure, pulmonary capillary wedge pressure, cardiac index, and peak oxygen consumption were 7 ± 5 mmHg, 10 ± 7 mmHg, 2.7 ± 0.5 L/min/m2, and 13.2 ± 3.0 mL/min/kg, respectively. Pulse pressure, stroke volume, right atrial pressure, mean pulmonary artery pressure, and pulmonary capillary wedge pressure were significantly associated with peak oxygen consumption. Multivariate linear regression analysis of factors predicting peak oxygen consumption revealed that pulse pressure, right atrial pressure, and aortic insufficiency remained independent predictors (β = 0.401, p = 0.007; β = − 0.558, p < 0.001; β = − 0.369, p = 0.010, respectively). Our findings suggests that cardiac reserve, volume status, right ventricular function, and aortic insufficiency predict exercise capacity in patients with a left ventricular assist device.
引用
收藏
页码:7 / 14
页数:7
相关论文
共 50 条
  • [41] PARADOXICAL RIGHT-VENTRICULAR COMPRESSION DURING EXERCISE IN PATIENTS CHRONICALLY SUPPORTED WITH A LEFT-VENTRICULAR ASSIST DEVICE
    BRANCH, K
    JASKI, B
    GORDON, J
    ADAMSON, R
    PETERSON, K
    DEMBITSKY, W
    CIRCULATION, 1995, 92 (08) : 232 - 232
  • [42] HEMODYNAMIC EXERCISE RESPONSES AND QUALITY OF LIFE IN SMALL BODY SURFACE AREA PATIENTS WITH LEFT VENTRICULAR ASSIST DEVICE
    Sato, Takuma
    Nagai, Toshiyuki
    Takenaka, Sakae
    Kazui, Sho
    Yasui, Yutaro
    Saiin, Kohei
    Takahashi, Yuki
    Naito, Seiichiro
    Mizuguchi, Yoshifumi
    Tada, Atsushi
    Ishizaka, Suguru
    Kobayashi, Yuta
    Omote, Kazunori
    Kamiya, Kiwamu
    Wakasa, Satoru
    Anzai, Toshihisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 513 - 513
  • [43] Markers of Right Ventricle Dysfunction Predict Exercise Capacity on Left Ventricular Assist Device (LVAD) Patients
    Bouzas-Cruz, N.
    Koshy, A.
    Gonzalez-Fernandez, O.
    Ferrera, C.
    Green, T.
    Okwose, N.
    Woods, A.
    Tovey, S.
    Robinson-Smith, N.
    McDiarmid, A.
    Parry, G.
    Gonzalez-Juanatey, J.
    Schueler, S.
    MacGowan, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S450 - S450
  • [44] Effect of Heart Rate Reserve on Exercise Capacity in Patients Treated with a Continuous Left Ventricular Assist Device
    Mirza, Kiran K.
    Cuomo, Kimberly
    Jung, Mette H.
    Russell, Stuart D.
    Gustafsson, Finn
    ASAIO JOURNAL, 2020, 66 (02) : 160 - 165
  • [45] What Hemodynamic Parameters Are Predictive of Peak VO2 in Patients Supported by Left Ventricular Assist Devices?
    Rakita, Val
    Moss, Noah
    Lala, Anu
    Contreras, Johanna
    Trivieri, Maria
    Roldan, Julie
    Barghash, Maya
    Pawali, Amit
    Mitter, Sumeet S.
    Mancini, Donna M.
    CIRCULATION, 2018, 138
  • [46] The Value of Physiotherapeutic Tests Next to Cardiopulmonary Exercise Test to Assess Exercise Capacity in Left Ventricular Assist Device Patients
    Muller, A.
    Felix, E.
    Rommens, C.
    De Jonge, N.
    Szymanski, M. K.
    Gianoli, M.
    Ramjankhan, F. Z.
    Van Laake, L. W.
    Oerlemans, M. I.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S64 - S64
  • [47] Assessment of submaximal exercise capacity in patients with left ventricular assist devices
    Foray, A
    Williams, D
    Reemtsma, K
    Oz, M
    Mancini, D
    CIRCULATION, 1996, 94 (09) : 222 - 226
  • [48] Subacute Left Ventricular Rupture Supported with a Percutaneous Left Ventricular Assist Device
    Korabathina, Ravikiran
    Duc Thinh Pham
    Kapur, Navin K.
    JOURNAL OF INVASIVE CARDIOLOGY, 2011, 23 (06): : 246 - 247
  • [49] In Patients Supported by a Left Ventricular Assist Device, Bi-Ventricular Pacing does not Offer Hemodynamic Improvement over Right Ventricular Pacing
    Inampudi, Chakradhari
    Johnson, Frances
    Tahir, Rizwan
    Tandon, Rudhir
    Iqbal, Omer J.
    Emerenini, Uzodinma
    Giudici, Michael C.
    Cotarlan, Vlad
    CIRCULATION, 2015, 132
  • [50] Longitudinal assessment of myocardial viability and left ventricular function in patients supported by a left ventricular assist device
    Gupta, D.
    Skali, H.
    Rivero, J.
    Campbell, P.
    Couper, G.
    Givertz, M.
    Mehra, M.
    Di Carli, M.
    Solomon, S.
    Pfeffer, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2013, 12 : S215 - S215