Hemodynamic parameters at rest predicting exercise capacity in patients supported with left ventricular assist device

被引:0
|
作者
Hirotoshi Kato
Togo Iwahana
Ryohei Ono
Sho Okada
Goro Matsumiya
Yoshio Kobayashi
机构
[1] Chiba University Graduate School of Medicine,Department of Cardiovascular Medicine
[2] Chiba University Graduate School of Medicine,Department of Cardiovascular Surgery
来源
关键词
Left ventricular assist device; Exercise capacity; Hemodynamic;
D O I
暂无
中图分类号
学科分类号
摘要
Left ventricular assist devices improve prognosis and quality of life, but exercise capacity remains limited in most patients after device implantation. Left ventricular assist device optimization through right heart catheterization reduces device-related complications. However, hemodynamic parameters associated with exercise capacity under optimized conditions. The aim of this study was to elucidate the predictors of exercise capacity from hemodynamic parameters at rest after left ventricular assist device optimization. We retrospectively reviewed 24 patients who underwent a ramp test with right heart catheterization, echocardiography and cardiopulmonary exercise testing more than 6 months after left ventricular assist device implantation. Pump speed was optimized to a lower setting that achieved right atrial pressure < 12 mmHg, pulmonary capillary wedge pressure < 18 mmHg, and cardiac index > 2.2 L/min/m2, then exercise capacity was assessed by cardiopulmonary exercise testing. After left ventricular assist device optimization, the mean right atrial pressure, pulmonary capillary wedge pressure, cardiac index, and peak oxygen consumption were 7 ± 5 mmHg, 10 ± 7 mmHg, 2.7 ± 0.5 L/min/m2, and 13.2 ± 3.0 mL/min/kg, respectively. Pulse pressure, stroke volume, right atrial pressure, mean pulmonary artery pressure, and pulmonary capillary wedge pressure were significantly associated with peak oxygen consumption. Multivariate linear regression analysis of factors predicting peak oxygen consumption revealed that pulse pressure, right atrial pressure, and aortic insufficiency remained independent predictors (β = 0.401, p = 0.007; β = − 0.558, p < 0.001; β = − 0.369, p = 0.010, respectively). Our findings suggests that cardiac reserve, volume status, right ventricular function, and aortic insufficiency predict exercise capacity in patients with a left ventricular assist device.
引用
收藏
页码:7 / 14
页数:7
相关论文
共 50 条
  • [1] Hemodynamic parameters at rest predicting exercise capacity in patients supported with left ventricular assist device
    Kato, Hirotoshi
    Iwahana, Togo
    Ono, Ryohei
    Okada, Sho
    Matsumiya, Goro
    Kobayashi, Yoshio
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (01) : 7 - 14
  • [2] Associations between hemodynamic parameters at rest and exercise capacity in patients with implantable left ventricular assist devices
    Kondo, Toru
    Okumura, Takahiro
    Oishi, Hideo
    Arao, Yoshihito
    Kato, Hiroo
    Yamaguchi, Shogo
    Kuwayama, Tasuku
    Haga, Tomoaki
    Yokoi, Tsuyoshi
    Hiraiwa, Hiroaki
    Fukaya, Kenji
    Sawamura, Akinori
    Morimoto, Ryota
    Mutsuga, Masato
    Fujimoto, Kazuro
    Usui, Akihiko
    Murohara, Toyoaki
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (03): : 174 - 180
  • [3] Chronotropic Incompetence May Impact Exercise Capacity in Patients Supported by Left Ventricular Assist Device
    Garan, A. R.
    Nahumi, N.
    Han, J.
    Colombo, P.
    Yuzefpolskaya, M.
    Te-Frey, R.
    Takayama, H.
    Naka, Y.
    Uriel, N.
    Jorde, U. P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S93 - S93
  • [4] Exercise in heart failure patients supported with a left ventricular assist device
    Jung, Mette Holme
    Gustafsson, Finn
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : 489 - 496
  • [5] Peak Exercise Capacity is a Poor Indicator of Functional Capacity for Patients Supported by a Continuous Flow Left Ventricular Assist Device
    Nahumi, Nadav
    Garan, Arthur R.
    Uriel, Nir
    Han, Jason
    Morrison, Kerry A.
    Thomas, Sunu S.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Jorde, Ulrich P.
    CIRCULATION, 2013, 128 (22)
  • [6] Exercise physiology, testing, and training in patients supported by a left ventricular assist device
    Loyaga-Rendon, Renzo Y.
    Plaisance, Eric P.
    Arena, Ross
    Shah, Keyur
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (08): : 1005 - 1016
  • [7] Hemodynamic Response to Exercise in Patients Supported by Continuous Flow Left Ventricular Assist Devices
    Moss, Noah
    Rakita, Val
    Lala, Anuradha
    Parikh, Adi
    Roldan, Julie
    Mitter, Sumeet S.
    Anyanwu, Anelechi
    Campoli, Michelle
    Burkhoff, Dan
    Mancini, Donna M.
    JACC-HEART FAILURE, 2020, 8 (04) : 291 - 301
  • [8] Adaptive Pump Speed Algorithms to Improve Exercise Capacity in Patients Supported with a Left-Ventricular Assist Device
    Schmidt, Thomas
    Reiss, Nils
    Deniz, Ezin
    Feldmann, Christina
    Hein, Andreas
    Hoffmann, Jan-Dirk
    Roebesaat, Jenny Inge
    Schmitto, Jan Dieter
    Willemsen, Detlev
    Mueller-Von Aschwege, Frerk
    HEALTH INFORMATICS MEETS EHEALTH: DIGITAL INSIGHT - INFORMATION-DRIVEN HEALTH & CARE, 2017, 236 : 235 - 240
  • [9] Effects of pump speed changes on exercise capacity in patients supported with a left ventricular assist device-an overview
    Schmidt, Thomas
    Bjarnason-Wehrens, Birna
    Schulte-Eistrup, Sebastian
    Reiss, Nils
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S1802 - S1810
  • [10] Exercise capacity recovers slowly but fully in patients with a left ventricular assist device
    Texas Heart Institute, St. Luke's Episcopal Hospital, Houston, TX, United States
    不详
    ASAIO J., 5 (M568-M570):