Virtual monoenergetic micro-CT imaging in mice with artificial intelligence

被引:0
|
作者
Brent van der Heyden
Stijn Roden
Rüveyda Dok
Sandra Nuyts
Edmond Sterpin
机构
[1] KU Leuven,Department of Oncology, Laboratory of Experimental Radiotherapy
[2] UCLouvain,Institut de Recherche Expérimentale Et Clinique, Molecular Imaging Radiotherapy and Oncology Lab
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Micro cone-beam computed tomography (µCBCT) imaging is of utmost importance for carrying out extensive preclinical research in rodents. The imaging of animals is an essential step prior to preclinical precision irradiation, but also in the longitudinal assessment of treatment outcomes. However, imaging artifacts such as beam hardening will occur due to the low energetic nature of the X-ray imaging beam (i.e., 60 kVp). Beam hardening artifacts are especially difficult to resolve in a ‘pancake’ imaging geometry with stationary source and detector, where the animal is rotated around its sagittal axis, and the X-ray imaging beam crosses a wide range of thicknesses. In this study, a seven-layer U-Net based network architecture (vMonoCT) is adopted to predict virtual monoenergetic X-ray projections from polyenergetic X-ray projections. A Monte Carlo simulation model is developed to compose a training dataset of 1890 projection pairs. Here, a series of digital anthropomorphic mouse phantoms was derived from the reference DigiMouse phantom as simulation geometry. vMonoCT was trained on 1512 projection pairs (= 80%) and tested on 378 projection pairs (= 20%). The percentage error calculated for the test dataset was 1.7 ± 0.4%. Additionally, the vMonoCT model was evaluated on a retrospective projection dataset of five mice and one frozen cadaver. It was found that beam hardening artifacts were minimized after image reconstruction of the vMonoCT-corrected projections, and that anatomically incorrect gradient errors were corrected in the cranium up to 15%. Our results disclose the potential of Artificial Intelligence to enhance the µCBCT image quality in biomedical applications. vMonoCT is expected to contribute to the reproducibility of quantitative preclinical applications such as precision irradiations in X-ray cabinets, and to the evaluation of longitudinal imaging data in extensive preclinical studies.
引用
收藏
相关论文
共 50 条
  • [1] Virtual monoenergetic micro-CT imaging in mice with artificial intelligence
    van der Heyden, Brent
    Roden, Stijn
    Dok, Rueveyda
    Nuyts, Sandra
    Sterpin, Edmond
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] Investigating the effect of longitudinal micro-CT imaging on tumour growth in mice
    Foster, W. Kyle
    Ford, Nancy L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02): : 315 - 326
  • [3] Micro-CT Imaging of MEMS Components
    Ryan F. Fisher
    David E. Hintenlang
    Journal of Nondestructive Evaluation, 2008, 27 : 115 - 125
  • [4] Cryogenic micro-CT imaging of tissues
    Jorgensen, Steven M.
    Turner, Russell T.
    Ritman, Erik L.
    Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [5] Respiratory gated micro-CT imaging
    Cody, D
    Collier, D
    Johnson, E
    Rivera, B
    Price, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408
  • [6] Whole Placentome Imaging by Micro-CT
    Barapatre, Nirav
    Achterhold, Klaus
    Kampfer, Cornelia
    Rubelmann, Tanja
    von Koch, Franz Edler
    Pfeiffer, Franz
    Schmitz, Christoph
    Frank, Hans-Georg
    REPRODUCTIVE SCIENCES, 2023, 30 : 157A - 157A
  • [7] Temporal and spectral imaging with micro-CT
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    MEDICAL PHYSICS, 2012, 39 (08) : 4943 - 4958
  • [8] Micro-CT Imaging of MEMS Components
    Fisher, Ryan F.
    Hintenlang, David E.
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2008, 27 (04) : 115 - 125
  • [9] Virtual Monoenergetic CT Imaging via Deep Learning
    Cong, Wenxiang
    Xi, Yan
    Fitzgerald, Paul
    De Man, Bruno
    Wang, Ge
    PATTERNS, 2020, 1 (08):
  • [10] A comparison of three micro-CT imaging systems for in vivo experimental research in mice
    Botter, Sander
    Kuhn, Gisela
    Seebeck, Petra
    Born, Walter
    Fuchs, Bruno
    SWISS MEDICAL WEEKLY, 2015, 145 : 71S - 71S