The fouling in the tubular heat exchanger of Algiers refinery

被引:0
|
作者
Rima Harche
Abdelkader Mouheb
Rafik Absi
机构
[1] University of Sciences and Technology Houari Boumediene (USTHB),Laboratory of Transfer Phenomenon, Department of Chemical Engineering, Faculty of Mechanical and Process Engineering
[2] EBI (Ecole de Biologie Industrielle),undefined
[3] Industrial Biology School,undefined
[4] Inst. Polytech. Saint-Louis,undefined
来源
Heat and Mass Transfer | 2016年 / 52卷
关键词
Pressure Drop; Heat Transfer Coefficient; Heat Exchanger; Distillation Unit; Heat Flow Rate;
D O I
暂无
中图分类号
学科分类号
摘要
Crude oil fouling in refinery preheat exchangers is a chronic operational problem that compromises energy recovery in these systems. Progress is hindered by the lack of quantitative knowledge of the dynamic effects of fouling on heat exchanger transfer and pressure drops. In subject of this work is an experimental determination of the thermal fouling resistance in the tubular heat exchanger of the crude oil preheats trains installed in an Algiers refinery. By measuring the inlet and outlet temperatures and mass flows of the two fluids, the overall heat transfer coefficient has been determined. Determining the overall heat transfer coefficient for the heat exchanger with clean and fouled surfaces, the fouling resistance was calculated. The results obtained from the two cells of exchangers studies, showed that the fouling resistance increased with time presented an exponential evolution in agreement with the model suggested by Kern and Seaton, with the existence of fluctuation caused by the instability of the flow rate and the impact between the particles. The bad cleaning of the heat exchangers involved the absence of the induction period and caused consequently, high values of the fouling resistance in a relatively short period of time.
引用
收藏
页码:947 / 956
页数:9
相关论文
共 50 条
  • [31] Mitigate fouling to improve heat exchanger reliability
    Joshi, HM
    HYDROCARBON PROCESSING, 1999, 78 (01): : 93 - 95
  • [32] The impact of crystallization fouling on a microscale heat exchanger
    Mayer, Moriz
    Bucko, Juergen
    Benzinger, Walther
    Dittmeyer, Roland
    Augustin, Wolfgang
    Scholl, Stephan
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 40 : 126 - 131
  • [33] Investigation on Crystallization Fouling in Micro Heat Exchanger
    Bucko, Juergen
    Mayer, Moriz
    Benzinger, Walther
    Augustin, Wolfgang
    Scholl, Stephan
    Dittmeyer, Roland
    CHEMIE INGENIEUR TECHNIK, 2012, 84 (04) : 491 - 502
  • [34] Fouling of CS heat exchanger from MIC?
    Krisher, AS
    MATERIALS PERFORMANCE, 1999, 38 (06) : 9 - 9
  • [35] A review of milk fouling on heat exchanger surfaces
    Sadeghinezhad, Emad
    Kazi, Salim Newaz
    Badarudin, Ahmad
    Zubair, Mohd Nashrul M.
    Dehkordi, Babak Lotfizadeh
    Oon, Cheen Sean
    REVIEWS IN CHEMICAL ENGINEERING, 2013, 29 (03) : 169 - 188
  • [36] Influence of surface properties on heat exchanger fouling
    Zhao, Q
    Müller-Steinhagen, H
    PROCEEDINGS OF AN INTERNATIONAL CONFERENCE ON MITIGATION OF HEAT EXCHANGER FOULING AND ITS ECONOMIC AND ENVIRONMENTAL IMPLICATIONS, 2001, : 217 - 228
  • [37] Heat Exchanger Fouling and Cleaning-2011
    Mueller-Steinhagen, H.
    Malayeri, M. R.
    Watkinson, A. P.
    HEAT TRANSFER ENGINEERING, 2013, 34 (8-9) : 653 - 654
  • [38] Optimize heat exchanger operations by minimizing fouling
    Bailey, K
    HYDROCARBON PROCESSING, 1999, 78 (06): : 113 - +
  • [39] SIMULATION OF A SIMPLE TUBULAR HEAT EXCHANGER
    DAVIES, WDT
    PROCESS CONTROL AND AUTOMATION, 1966, 13 (08): : 25 - &
  • [40] Development of a Dynamic Fouling Model for a Heat Exchanger
    Zahid, Khayyam
    Patel, Rajnikant
    Mujtaba, Iqbal
    PRES2016: 19TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELING AND OPTIMIZATION FOR ENERGY SAVINGS AND POLLUTION REDUCTION, 2016, 52 : 1135 - 1140