Application of CdTe Detector for Determining Uranium Enrichment on 89–100 keV γ- and X-ray Radiation

被引:0
|
作者
S. M. Brodsky
机构
[1] Research Institute of Technical Physics and Automation (NIITFA),
来源
Atomic Energy | 2013年 / 114卷
关键词
Uranium; Uranium Dioxide; Uranium Enrichment; Mass Coefficient; 235U Content;
D O I
暂无
中图分类号
学科分类号
摘要
The results of studies of a standards-free method of determining uranium enrichment according to characteristic γ- and x-ray radiation detected with a CdTe detector (sensitive surface area 25 mm2) are presented. A method for processing the spectra based on fitting with analytic functions that effectively take account of the asymmetry of the total absorption peaks is proposed to separate the lines of the photon radiation of the isotopes 235U and 238U in the energy range 89–100 keV. The enrichment with the isotope 235U in uranium dioxide pellets is measured. It is shown that the new method makes it possible to measure the enrichment of uranium with relative error 1–5% for 235U content in the isotope mixture 0.4–26%.
引用
收藏
页码:421 / 427
页数:6
相关论文
共 50 条
  • [41] CdTe Linear Pixel X-Ray Detector With Enhanced Spectrometric Performance for High Flux X-Ray Imaging
    Brambilla, A.
    Ouvrier-Buffet, P.
    Rinkel, J.
    Gonon, G.
    Boudou, C.
    Verger, L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1552 - 1558
  • [42] Recent developments on a CdTe based X-ray detector for digital radiography
    Glasser, F
    Martin, JL
    Thevenin, B
    Schermesser, P
    Pantigny, P
    Laurent, JY
    Rambaud, P
    Pitault, B
    Paltrier, S
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 513 - 519
  • [43] CdTe focal plane detector for hard X-ray focusing optics
    Seller, Paul
    Wilson, Matthew D.
    Veale, Matthew C.
    Schneider, Andreas
    Gaskin, Jessica
    Wilson-Hodge, Colleen
    Christe, Steven
    Shih, Albert Y.
    Gregory, Kyle
    Inglis, Andrew
    Panessa, Marco
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XIX, 2015, 9601
  • [44] An analytical X-ray CdTe detector response matrix for incomplete charge collection correction for photon energies up to 300 keV
    Kurkova, Dana
    Judas, Libor
    RADIATION PHYSICS AND CHEMISTRY, 2018, 146 : 26 - 33
  • [45] X-ray, gamma-ray detector/imager by CdTe semiconductor and its applications
    Aoki, Toru
    Morii, Hisashi
    Nakashima, Takuya
    Takahashi, Yasuyuki
    Ohashi, Gosuke
    Tomita, Yasuhiro
    Neo, Yoichiro
    Mimura, Hidenori
    8TH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2008, 7008
  • [46] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    NASA Goddard Space Flight Center, Greenbelt, MD 20771, United States
    不详
    不详
    Nucl Instrum Methods Phys Res Sect A, 1-2 (138-145):
  • [47] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    Stahle, CM
    Parker, BH
    Parsons, AM
    Barbier, LM
    Barthelmy, SD
    Gehrels, NA
    Palmer, DM
    Snodgrass, SJ
    Tueller, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 138 - 145
  • [48] SCINTILLATION DETECTOR FOR X-RAY RADIATION OF LIGHT ELEMENTS
    ALPEROVI.VR
    KOMYAK, NI
    KHAI, DM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (01): : 45 - &
  • [49] DETECTOR OF X-RAY RADIATION IN 1 TO 12 A BAND
    IPATKIN, IS
    BULATOV, BP
    ANTONOV, EA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (03): : 577 - &
  • [50] X-Ray Performance of SiC NPN Radiation Detector
    Wang, Jing
    Zhou, Leidang
    Chen, Liang
    Zhang, Silong
    Wang, Fangbao
    Fan, Tingting
    Chen, Zhuo
    Bai, Song
    Ouyang, Xiaoping
    MICROMACHINES, 2025, 16 (01)