Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study

被引:0
|
作者
Won Ho Kim
Byoung Kwon Lee
Sahng Lee
Jae-Min Shim
Jung-Sun Kim
Byoung-Keuk Kim
Young-Guk Ko
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
机构
[1] Eulji University College of Medicine,Division of Cardiology, Eulji University Hospital
[2] Yonsei University College of Medicine,Department of Internal Medicine, Gangnam Severance Hospital
[3] Yonsei University College of Medicine,Division of Cardiology, Yonsei Cardiovascular Center
来源
Clinical Research in Cardiology | 2010年 / 99卷
关键词
Optical coherence tomography; Stent;
D O I
暂无
中图分类号
学科分类号
摘要
Morphologic changes of small-sized post-stent malapposition have not been sufficiently evaluated. We investigated serial changes of minimal post-stent malapposition with a follow-up optical coherence tomography (OCT) study. Post-stent OCT and intravascular ultrasound (IVUS) and follow-up OCT were performed in 26 patients with minimal post-stent malapposition. Serial changes of number and percent of malapposition struts, and mean extra-stent malapposition area were measured in OCT analysis. Zotarolimus-eluting stent (ZES), sirolimus-eluting stent (SES), and paclitaxel-eluting stent (PES) were deployed in 17, 7 and 2 patients, respectively. Mean durations of the follow-up OCT study were 5.7 ± 3.0 months. The minimal post-stent malapposition cannot be detected by the IVUS, but be visualized with an OCT examination. According to different drug-eluting stents, malapposed stent struts were defined as the struts with detachment from the vessel wall ≥160 μm for SES, ≥130 μm for PES, and ≥110 μm for ZES. The percent of malapposition struts significantly decreased from 12.2 ± 11.0% post-stent to 1.0 ± 2.2% follow-up (P < 0.001). There was a significant decrease in the mean extra-stent malapposition area from 0.35 ± 0.16 mm2 post-stent to 0.04 ± 0.11 mm2 follow-up (P < 0.001). Complete disappearance of stent malapposition was also observed in 22 (85%) patients. In conclusion, minimal stent malapposition which is not detectable by IVUS may disappear or decrease in follow-up OCT evaluation.
引用
收藏
页码:639 / 644
页数:5
相关论文
共 50 条
  • [31] Comparative endoluminal visualization of TAXUS crush-stenting at 9 months follow-up by intravascular ultrasound and optical coherence tomography
    Buellesfeld, L
    Lim, V
    Gerckens, U
    Mueller, R
    Grube, E
    ZEITSCHRIFT FUR KARDIOLOGIE, 2005, 94 (10): : 690 - 694
  • [32] Clinical significance of healed plaque detected by optical coherence tomography: a 2-year follow-up study
    Kurihara, Osamu
    Russo, Michele
    Kim, Hyung Oh
    Araki, Makoto
    Shinohara, Hiroki
    Lee, Hang
    Takano, Masamichi
    Mizuno, Kyoichi
    Jang, Ik-Kyung
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2020, 50 (04) : 895 - 902
  • [33] Clinical significance of healed plaque detected by optical coherence tomography: a 2-year follow-up study
    Osamu Kurihara
    Michele Russo
    Hyung Oh Kim
    Makoto Araki
    Hiroki Shinohara
    Hang Lee
    Masamichi Takano
    Kyoichi Mizuno
    Ik-Kyung Jang
    Journal of Thrombosis and Thrombolysis, 2020, 50 : 895 - 902
  • [34] Follow-up of lupus choroidopathy with optical coherence tomography
    Ozturk, B. T.
    Bozkurt, B.
    Karademir, Z.
    Kerimoglu, H.
    LUPUS, 2011, 20 (10) : 1076 - 1078
  • [35] Natural consequence of post-intervention stent malapposition, thrombus, tissue prolapse, and dissection assessed by optical coherence tomography at mid-term follow-up
    Kawamori, Hiroyuki
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Matsumoto, Daisuke
    Nakagawa, Masayuki
    Nagoshi, Ryoji
    Kozuki, Amane
    Hariki, Hirotoshi
    Inoue, Takumi
    Osue, Tsuyoshi
    Taniguchi, Yu
    Nishio, Ryo
    Hiranuma, Noritoshi
    Hirata, Ken-ichi
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (09) : 865 - 875
  • [36] Temporal course of neointimal hyperplasia following drug-eluting stent implantation: a serial follow-up optical coherence tomography analysis
    Lee, Seung-Yul
    Hong, Myeong-Ki
    Mintz, Gary S.
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06): : 1003 - 1011
  • [37] Temporal course of neointimal hyperplasia following drug-eluting stent implantation: a serial follow-up optical coherence tomography analysis
    Seung-Yul Lee
    Myeong-Ki Hong
    Gary S. Mintz
    Dong-Ho Shin
    Jung-Sun Kim
    Byeong-Keuk Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1003 - 1011
  • [38] In-stent neointimal changes: two-year follow-up intravascular ultrasound (IVUS) study in 120 lesions
    Hong, MK
    Lee, CW
    Kim, YH
    Park, KM
    Park, DW
    Kim, MJ
    Song, JM
    Han, KH
    Kang, DH
    Song, JK
    Im, JJ
    Park, SW
    Park, SJ
    CIRCULATION, 2004, 110 (17) : 525 - 526
  • [39] Use of intravascular optical coherence tomography or intravascular ultrasound to guide stent implantation. The choice is yours!
    Regar, Evelyn
    EUROINTERVENTION, 2021, 16 (13) : 1041 - 1043
  • [40] Combined intracoronary 2D–3D optical coherence tomography and intravascular ultrasound imaging in left main severe stent malapposition
    Cerrato E.
    Biagioni C.
    Jimenez-Quevedo P.
    Nuñez-Gil I.J.
    Gonzalo N.
    Escaned J.
    Cardiovascular Intervention and Therapeutics, 2018, 33 (3) : 288 - 290