Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study

被引:0
|
作者
Won Ho Kim
Byoung Kwon Lee
Sahng Lee
Jae-Min Shim
Jung-Sun Kim
Byoung-Keuk Kim
Young-Guk Ko
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
机构
[1] Eulji University College of Medicine,Division of Cardiology, Eulji University Hospital
[2] Yonsei University College of Medicine,Department of Internal Medicine, Gangnam Severance Hospital
[3] Yonsei University College of Medicine,Division of Cardiology, Yonsei Cardiovascular Center
来源
Clinical Research in Cardiology | 2010年 / 99卷
关键词
Optical coherence tomography; Stent;
D O I
暂无
中图分类号
学科分类号
摘要
Morphologic changes of small-sized post-stent malapposition have not been sufficiently evaluated. We investigated serial changes of minimal post-stent malapposition with a follow-up optical coherence tomography (OCT) study. Post-stent OCT and intravascular ultrasound (IVUS) and follow-up OCT were performed in 26 patients with minimal post-stent malapposition. Serial changes of number and percent of malapposition struts, and mean extra-stent malapposition area were measured in OCT analysis. Zotarolimus-eluting stent (ZES), sirolimus-eluting stent (SES), and paclitaxel-eluting stent (PES) were deployed in 17, 7 and 2 patients, respectively. Mean durations of the follow-up OCT study were 5.7 ± 3.0 months. The minimal post-stent malapposition cannot be detected by the IVUS, but be visualized with an OCT examination. According to different drug-eluting stents, malapposed stent struts were defined as the struts with detachment from the vessel wall ≥160 μm for SES, ≥130 μm for PES, and ≥110 μm for ZES. The percent of malapposition struts significantly decreased from 12.2 ± 11.0% post-stent to 1.0 ± 2.2% follow-up (P < 0.001). There was a significant decrease in the mean extra-stent malapposition area from 0.35 ± 0.16 mm2 post-stent to 0.04 ± 0.11 mm2 follow-up (P < 0.001). Complete disappearance of stent malapposition was also observed in 22 (85%) patients. In conclusion, minimal stent malapposition which is not detectable by IVUS may disappear or decrease in follow-up OCT evaluation.
引用
收藏
页码:639 / 644
页数:5
相关论文
共 50 条
  • [1] Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study
    Kim, Won Ho
    Lee, Byoung Kwon
    Lee, Sahng
    Shim, Jae-Min
    Kim, Jung-Sun
    Kim, Byoung-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    CLINICAL RESEARCH IN CARDIOLOGY, 2010, 99 (10) : 639 - 644
  • [2] SERIAL CHANGES OF TINY STENT MALAPPOSITION NOT DETECTED BY INTRAVASCULAR ULTRASOUND: FOLLOW-UP OPTICAL COHERENCE TOMOGRAPHY STUDY
    Kim, Won Ho
    Hong, Myeong-Ki
    Shim, Jaemin
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [3] Comparison of Intravascular Ultrasound and Optical Coherence Tomography for the Evaluation of Stent Segment Malapposition
    Rosenthal, Noah
    Guagliumi, Giulio
    Sirbu, Vasile
    Zoccai, Giuseppe B.
    Fioca, Luigi
    Musumeci, Giuseppe
    Mathiasvili, Alexandre
    Trivisonno, Antonio
    Kyono, Hiro
    Tahara, Satoko
    Simon, Daniel I.
    Costa, Marco
    Bezerra, Hiram G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A22 - A22
  • [4] Stent implant follow-up in intravascular optical coherence tomography images
    Gozde Unal
    Serhan Gurmeric
    Stéphane Guy Carlier
    The International Journal of Cardiovascular Imaging, 2010, 26 : 809 - 816
  • [5] Stent implant follow-up in intravascular optical coherence tomography images
    Unal, Gozde
    Gurmeric, Serhan
    Carlier, Stephane Guy
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (07): : 809 - 816
  • [6] Serial (Baseline and Follow-Up) Optical Coherence Tomography Analysis of the Causes of Stent Failure
    Zhang, Mingyou
    Ishida, Masaru
    Mintz, Gary
    Matsumura, Mitsuaki
    Chen, Zhaoyang
    Ali, Ziad
    Porter, Craig
    Cao, Jane
    Pappas, Thomas
    Moses, Jeffrey W.
    Jeremias, Allen
    Shlofmitz, Richard
    Maehara, Akiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B352 - B352
  • [7] Late acquired stent malapposition detected by optical coherence tomography examination
    Bouki, Konstantina P.
    Chatzopoulos, Dionissios N.
    Katsafados, Mihail G.
    Elaiopoulos, Dimitrios A.
    Psychari, Stavroula N.
    Apostolou, Thomas S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 137 (03) : E77 - E78
  • [8] Severe acute stent malapposition follow-up: 3-month and 12-month serial quantitative analyses by optical coherence tomography
    Hong, Sung-Jin
    Park, Keun-Hee
    Ahn, Chul-Min
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 299 : 81 - 86
  • [9] Severe Acute Stent Malapposition Follow-Up: 3-Month and 12-Month Serial Quantitative Analyses by Optical Coherence Tomography
    Hong, Sung-Jin
    Ahn, Chul-Min
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    CIRCULATION, 2019, 140
  • [10] Predictors Of Acute And Late Persistent Stent Malapposition After Percutaneous Coronary Intervention: A Follow-up Optical Coherence Tomography Study
    Im, Eui
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Shin, Dong-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yang-Soo
    Hong, Myeong-Ki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B86 - B86