Seismic optimal design of hysteretic damping tuned mass damper (HD-TMD) for acceleration response control

被引:0
|
作者
Yue Xiang
Ping Tan
Hui He
Hongcan Yao
Xiaojun Zheng
机构
[1] Guangzhou University,School of Civil Engineering
[2] Guangzhou University,Key Laboratory of Earthquake Resistance, Earthquake Mitigation, and Structural Safety, Ministry of Education
[3] Hunan Institute of Technology,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The hysteretic damping tuned mass damper (HD-TMD), which exhibits linear damping force, has been achieved by variable friction devices. Such devices own the advantages of stable mitigation capacity and easy maintenance compared to viscous damping devices. Previous studies have mainly concentrated on the vibration mitigation effect of the HD-TMD system without explicit consideration of structural acceleration control. In this context, seismic optimizations of HD-TMD for structural acceleration control were presented, and the effective damping of HD-TMD was investigated. H∞ optimizations of the HD-TMD were considered for undamped and lightly damped structures with fixed-point theory, where the closed-form solutions of optimal and improved parameters were derived. Parametric analysis for the dynamic amplification factors (DAFs) of structural acceleration revealed that the closed-form solutions effectively tuned the DAF into double peaks and reduced the maximum response overall frequency. H2 optimizations were conducted with residue theory for the optimization of the undamped structure, and the optimal parameters of HD-TMD subjected to stochastic ground excitation were obtained by numerical searching and curve-fitting techniques. Effective damping of the HD-TMD was consequently examined using the stochastic stationary process in which the damping effect additionally provided to the structure was measured. The effectiveness of the proposed optimal solutions for the HD-TMD in the form of an available engineering variable friction device was thereby corroborated by twenty sets of seismic ground motions. Spectrum's results indicated that the proposed optimal parameters greatly improved the absolute structural acceleration response and provided excellent seismic mitigation capacity for structural displacement response. The response of the equivalent SDOF demonstrated almost the same trend of absolute structural acceleration reduction, which revealed the successful application of effective damping of HD-TMD for designers. Detailed analysis of the earthquake record indicated the functionality and effectiveness of the proposed methods of HD-TMD with the average absolute structural acceleration reduction ratio of 65.86% and 42.66% for maximum reduction and standard deviation reduction, respectively.
引用
收藏
页码:1583 / 1601
页数:18
相关论文
共 50 条
  • [31] Tuned negative stiffness⁃inertia mass damper parameters optimization and seismic response control
    Yi J.
    Xu K.
    He X.-H.
    Hua X.-G.
    Wen Q.
    Chen Z.-Q.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2024, 37 (06): : 1015 - 1022
  • [32] Negative stiffness enhanced tuned mass damper (NS-TMD) for seismic induced response mitigation of isolated bridges
    Jiang, Shaodong
    Ma, Ruisheng
    Bi, Kaiming
    Du, Xiuli
    Song, Jian
    ENGINEERING STRUCTURES, 2025, 325
  • [33] Optimum design of tuned mass damper systems for seismic structures
    Abdulsalam, I.
    Al-Janabi, M.
    Al-Taweel, M. G.
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES VII, 2009, 104 : 175 - 184
  • [34] Response control of chimneys using tuned mass damper, multi-tuned mass damper and tuned mass inerter system
    Rahman, Saba
    Jain, A. K.
    Jha, K. N.
    Bharti, S. D.
    Datta, T. K.
    STRUCTURES, 2024, 69
  • [35] Seismic control of structure with phase control active tuned mass damper
    Lai, Yong-An
    Luo, Wei-Chen
    Huang, Shieh-Kung
    Yang, Cho-Yen
    Chang, Chia-Ming
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (07):
  • [36] Hysteretic tuned mass damper with bumpers for seismic protection: Modeling, identification, and shaking table tests
    Janga, Vinay Yadav
    Gourishetty, Pranath Kumar
    Carboni, Biagio
    Quaranta, Giuseppe
    Lacarbonara, Walter
    JOURNAL OF SOUND AND VIBRATION, 2025, 597
  • [37] On Stochastic Design of Negative Stiffness Integrated Tuned Mass Damper (NS-TMD)
    Kamalesh Bhowmik
    Nirmalendu Debnath
    Journal of Vibration Engineering & Technologies, 2021, 9 : 2197 - 2211
  • [38] On Stochastic Design of Negative Stiffness Integrated Tuned Mass Damper (NS-TMD)
    Bhowmik, Kamalesh
    Debnath, Nirmalendu
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2021, 9 (08) : 2197 - 2211
  • [39] Optimal design of friction pendulum typed tuned mass damper
    Chung, Lap-Loi
    Wu, Lai-Yun
    Chen, Hsuan-Hung
    Huang, Hsu-Hui
    Lien, Kuan-Hua
    Journal of the Chinese Institute of Civil and Hydraulic Engineering, 2011, 23 (01): : 11 - 23
  • [40] Optimal Design and Analysis of Nonlinear Tuned Mass Damper System
    Yao, Ji
    Liu, Junfeng
    Hu, Yujun
    Zhang, Qing
    APPLIED SCIENCES-BASEL, 2023, 13 (14):