Dual Energy imaging in cardiovascular CT: Current status and impact on radiation, contrast and accuracy

被引:2
|
作者
Rajiah P. [1 ]
Halliburton S.S. [2 ]
机构
[1] Cardiothoracic Imaging, Department of Radiology, University Hospital Cleveland Case Medical Center, Case Western Reserve University School of Medicine, 11100 Euclid Avenue, Cleveland
[2] Imaging Institute, Heart and Vascular Institute Cleveland Clinic, Cleveland, OH
关键词
Cardiac; Contrast agent dose; CT; Dual energy; Radiation dose;
D O I
10.1007/s12410-014-9289-6
中图分类号
学科分类号
摘要
Dual-energy computed tomography (DECT) exploits the continuous energy distribution of x-rays to improve differentiation of tissues beyond what is possible with single-energy CT (SECT). DECT often uses smaller volumes of iodinated contrast agent and lower radiation doses than SECT. Clinical applications of DECT in cardiovascular imaging are emerging and include myocardial perfusion imaging, myocardial infarct and viability imaging, coronary plaque characterization, coronary stent assessment, and myocardial iron quantification. In this review, we discuss the available methods for acquiring and processing DECT data, the current status of DECT in cardiovascular imaging, and its impact on the dose of radiation and contrast agent. © 2014, Springer Science+Business Media New York.
引用
收藏
页码:1 / 11
相关论文
共 50 条
  • [31] Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose
    Uhrig, Monika
    Simons, David
    Kachelriess, Marc
    Pisana, Francesco
    Kuchenbecker, Stefan
    Schlemmer, Heinz-Peter
    CANCER IMAGING, 2016, 16
  • [32] CT imaging of appendicitis in adults: Current status
    Katz, DS
    Belfi, L
    Weston, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 87 - 88
  • [33] CT Imaging of Pulmonary Embolism: Current Status
    Apfaltrer P.
    Hanna E.L.
    Henzler T.
    Fink C.
    Schoepf U.J.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 476 - 484
  • [34] Identification of contrast media in PET/CT using dual energy CT
    Freedman, Nanette M. T.
    Moreno, Roberto Maass
    Le Meunier, Ludovic
    Bacharach, Stephen L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) : 523 - 527
  • [35] Improving diagnostic accuracy for arteries of lower extremities with dual-energy spectral CT imaging
    Jia, Xiaoqian
    Li, Xianjun
    Li, Jianying
    Tian, Qian
    Yao, Yue
    Zhu, Shumeng
    Sun, Jingtao
    Li, Yanan
    Zhao, Liang
    Shi, Yilei
    Tong, Wei
    Yang, Jian
    Guo, Jianxin
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 128
  • [36] Dual-Energy CT and Radiation Dose
    Reher, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (01) : 95 - 96
  • [37] Dual-energy CT Imaging Using a Single-energy CT Data via Deep Learning: A Contrast-enhanced CT Study
    Zhao, W.
    Lv, T.
    Chen, Y.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S43 - S43
  • [38] Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
    Yu, Lifeng
    Christner, Jodie A.
    Leng, Shuai
    Wang, Jia
    Fletcher, Joel G.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (12) : 6371 - 6379
  • [39] Dual energy iodine contrast imaging with mammography and tomosynthesis
    Reni, Baorui
    Ruth, Chris
    Zhang, Yiheng
    Smith, Andrew
    Kennedy, Don
    O'Keefe, Bernie
    Shaw, Ian
    Williams, Cornell
    Ye, Zhen
    Ingal, Elena
    Polischuk, Brad
    Jing, Zhenxue
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [40] Evaluation of Deformable Image Registration Accuracy and Its Impact On Dual-Energy CT Images
    Huang, J.
    Matrosic, C.
    Lawless, M.
    Di Maso, L.
    Miller, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E210 - E210