A comparison of the survival of fibre posts cemented with two different composite resin systems

被引:0
|
作者
S. B. Mehta
B. J. Millar
机构
[1] General Dental Practitioner/Part-time Clinical Teacher,Department of Primary Dental Care
[2] King's College London Dental Institute at Guy's,Department of Primary Dental Care
[3] King's College & St. Thomas' Hospitals,undefined
[4] Caldecot Road,undefined
[5] London,undefined
[6] SE5 9RW,undefined
[7] Senior Lecturer/Consultant in Restorative Dentistry and Director of Distance Learning,undefined
[8] King's College London Dental Institute at Guy's,undefined
[9] King's College & St. Thomas' Hospitals,undefined
[10] Caldecot Road,undefined
[11] London,undefined
[12] SE5 9RW,undefined
来源
British Dental Journal | 2008年 / 205卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Describes the results of 3-5 year audit on fibre resin posts used to restore endodontically treated teeth with the use of two differing resin luting agents.Highlights the importance of the appropriate choice of resin lute.Suggests that root fractures are seldom encountered with the use of FRPs but fractures occurring along the post-core interface appear to be a cause for concern.
引用
收藏
页码:E23 / E23
相关论文
共 50 条
  • [31] Shear bond strength of fibre-reinforced composite nets using two different adhesive systems
    Sfondrini, Maria Francesca
    Cacciafesta, Vittorio
    Scribante, Andrea
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (01) : 66 - 70
  • [32] Assessing Fracture Resistance of non Vital Teeth Using Two Different Composite Systems: Short-Fibre-Reinforced Composite and Glass Fibre Post with Microfilled Hybrid Composite
    Ileana Cimpean, Sanda
    Pop-Ciutrila, Ioana-Sofia
    Buduru, Smaranda
    Lacramioara Pavel, Liliana
    Florentina Florea, Daniela
    Gabriela Delean, Ada
    Moldovan, Marioara
    Cristian Dudescu, Mircea
    Berbece, Sorin
    Carina Voinescu, Doina
    Beznea, Adrian
    Negucioiu, Marius
    Stefanescu, Victorita
    MATERIALE PLASTICE, 2020, 57 (04) : 286 - 296
  • [33] Volumetric shrinkage of composite resin photocuring by two different methods
    Santos, MJMC
    Nagem, H
    Souza, MHS
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B208 - B208
  • [34] Volumetric shrinkage of composite resin photocuring by two different methods
    Santos, MJMC
    Nagem, H
    Souza, MHSE
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B197 - B197
  • [35] Coupling of composite resin cements to quartz fiber posts: A comparison of industrial and "chairside" treatments of the post surface
    Radovic, Ivana
    Monticelli, Francesca
    Cury, Alvaro Hafiz
    Bertelli, Egidio
    Vulicevic, Zoran R.
    Ferrari, Marco
    JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (01): : 57 - 66
  • [36] AN EVALUATION OF DIFFERENT COMPOSITE RESIN SYSTEMS FINISHED WITH VARIOUS ABRASIVES
    HERRGOTT, AML
    ZIEMIECKI, TL
    DENNISON, JB
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1989, 119 (06): : 729 - 732
  • [37] COMPOSITE RESIN ADHESION TO DENTIN USING DIFFERENT COMMERCIAL SYSTEMS
    ABATE, PF
    POLACK, M
    STEFANONI, JL
    MACCHI, RL
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 731 - 731
  • [38] A comparison of the mechanical properties in compression of two resin systems
    Khan, MZS
    Simpson, G
    Townsend, CR
    MATERIALS LETTERS, 2002, 52 (03) : 173 - 179
  • [39] Mechanical properties of glass-fibre-reinforced composite posts after laser irradiation with different energy densities
    Kirmali, Omer
    Akcakus Battal, Tuba
    Turker, Nurullah
    Dundar, Ayse
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (01) : 34 - 42
  • [40] Effect of Different Surface Treatments of Resin Relined Fiber Posts Cemented With Self-adhesive Resin Cement on Push-out and Microtensile Bond Strength Tests
    Machry, R., V
    Fontana, P. E.
    Bohrer, T. C.
    Valandro, L. F.
    Kaizer, O. B.
    OPERATIVE DENTISTRY, 2020, 45 (04) : E185 - E195