Management of pediatric radiation dose using Philips digital radiography

被引:0
|
作者
U. Neitzel
机构
[1] Philips Medical Systems,
来源
Pediatric Radiology | 2004年 / 34卷
关键词
Digital radiography; Radiation dose; Image quality; Pediatrics;
D O I
暂无
中图分类号
学科分类号
摘要
Digital radiography systems based on flat-panel detectors have been introduced into clinical practice in the past few years. The high detective quantum efficiency of these detectors allows the radiation dose to be reduced while maintaining image quality, an issue particularly significant for pediatric radiography. Another important aspect for dose optimization and monitoring is the integration of the detector into a computer-controlled x-ray examination system. This enables full control and complete reporting of all dose-relevant exposure parameters, including the determination of the exposure indicator and the patient dose (kerma-area product). In this paper the implementation of these principles in the Philips Digital Diagnost DR system is described and their relevance for pediatric applications is discussed.
引用
收藏
页码:S227 / S233
相关论文
共 50 条
  • [21] Radiation dose reduction in direct digital panoramic radiography
    Gavala, Sophia
    Donta, Catherine
    Tsiklakis, Kostas
    Boziari, Argyro
    Kamenopoulou, Vasiliki
    Stamatakis, Harry C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (01) : 42 - 48
  • [22] Management of pediatric radiation dose using GE fluoroscopic equipment
    Barry Belanger
    John Boudry
    Pediatric Radiology, 2006, 36 : 204 - 211
  • [23] Management of pediatric radiation dose using GE fluoroscopic equipment
    Belanger, Barry
    Boudry, John
    PEDIATRIC RADIOLOGY, 2006, 36 (Suppl 2) : 204 - 211
  • [24] Digital radiography of scoliosis with a scanning method: radiation dose optimization
    Håkan Geijer
    Bert Verdonck
    Karl-Wilhelm Beckman
    Torbjörn Andersson
    Jan Persliden
    European Radiology, 2003, 13 : 543 - 551
  • [25] ASSESSMENT OF RADIATION-DOSE IN DIGITAL STORAGE PHOSPHOR RADIOGRAPHY
    BICK, U
    FIEBICH, M
    LENZEN, H
    WIESMANN, W
    PETERS, PE
    RADIOLOGE, 1991, 31 (01): : 8 - 10
  • [26] Digital radiography of scoliosis with a scanning method: radiation dose optimization
    Geijer, H
    Verdonck, B
    Beckman, KW
    Andersson, T
    Persliden, J
    EUROPEAN RADIOLOGY, 2003, 13 (03) : 543 - 551
  • [27] Assessment Of Radiation Dose In Digital Radiography System -A Review Article
    Pise, Kunal
    Tivaskar, Suhas
    Luharia, Anurag
    Dhande, Rajasbala
    Pathade, Aniket
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 69 - 75
  • [28] Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction
    Hufton, AP
    Doyle, SM
    Carty, HML
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842): : 186 - 199
  • [29] Radiation Dose Management in Pediatric CT
    Verdun F.R.
    Alamo L.
    Miéville F.A.
    Gudinchet F.
    Current Radiology Reports, 2013, 1 (1) : 23 - 29
  • [30] New image quality and dose reduction technique for pediatric digital radiography
    Feghali, Joelle A.
    Chambers, Greg
    Delepierre, Julie
    Chapeliere, Sophie
    Mannes, Ines
    Adamsbaum, Catherine
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (7-8) : 463 - 470