The five-times-sit-to-stand test: validity, reliability and detectable change in older females

被引:1
|
作者
Allon Goldberg
Martina Chavis
Johnny Watkins
Tyler Wilson
机构
[1] Wayne State University,Department of Health Care Sciences, Physical Therapy Program, Mobility Research Laboratory
[2] Wayne State University,Institute of Gerontology
关键词
Dynamic balance; minimum detectable change; older adults; relative and absolute reliability; sit to stand;
D O I
10.1007/BF03325265
中图分类号
学科分类号
摘要
Background and aims: The five-timessit- to-stand test (FTSST) is a physical performance test commonly-used in clinical geriatric studies. The relationship between FTSST times and dynamic balance has not been widely investigated in older adults. The main objective of this study was to evaluate the validity of the FTSST as a measure of dynamic balance in older adults. A second objective was to quantify relative and absolute reliability, as well as minimum detectable change (MDC) of the FTSST in older adults. Methods: Twenty-nine females (mean age, 73.6 years) performed two trials of the FTSST, timed up and go (TUG), and functional reach (FR) tests. Validity of the FTSST as a measure of dynamic balance was evaluated by quantifying strength of relationships between the FTSST and two measures of dynamic balance, TUG and FR, using Pearson’s correlation coefficient. Measures of relative [intraclass correlation coefficient (ICC)] and absolute [standard error of measurement (SEM)] reliability, as well as the MDC at the 95% confidence level (MDC95) were computed for the FTSST. Results: The Pearson’s correlation coefficient between FTSST and TUG (r=0.64, p<0.001) indicates that FTSST is a valid measure of dynamic balance and functional mobility in older adults. The ICC2,1 of 0.95 is indicative of excellent relative reliability of the FTSST. SEM was 0.9 seconds and MDC95 was 2.5 seconds for the FTSST. SEM (6.3% of mean FTSST) and MDC (17.5% of mean FTSST) percent values were low. Conclusions: The FTSST is a valid measure of dynamic balance and functional mobility in older adults. The high ICC and low SEM and SEM% suggest excellent relative and absolute reliability and reproducibility of the FTSST in older adults. Change in FTSST performance should exceed 2.5 seconds to be considered real change beyond measurement error.
引用
收藏
页码:339 / 344
页数:5
相关论文
共 50 条
  • [41] Velocity of the Five Sit-to-Stand Test in Older Adults: A Systematic Review
    Jerez-Mayorga, Daniel
    Miranda-Fuentes, Claudia
    Perez-Doncel, Julieta
    Rool- Maureira, Barbara
    Saavedra-Rincon, Francisca
    Zambra-Alvarez, Rocio
    Intelangelo, Leonardo
    Guede-Roja, Francisco
    RETOS-NUEVAS TENDENCIAS EN EDUCACION FISICA DEPORTE Y RECREACION, 2022, (45): : 714 - 722
  • [42] Test-Retest Reliability and Concurrent Validity of the 30 second Sit to Stand Test in Adolescents
    Robinson, Katie J.
    Lubans, David R.
    Mavilidi, Myrto F.
    Ortega, Francisco B.
    Riley, Nicholas
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2024, 28 (01) : 109 - 118
  • [43] Validity, reliability, and measurement error of a sit-to-stand power test in older adults: A pre-registered study
    Balachandran, Anoop T.
    Vigotsky, Andrew D.
    Quiles, Norberto
    Mokkink, Lidwine B.
    Belio, Mark A.
    Glenn, Jordan McKenzie
    EXPERIMENTAL GERONTOLOGY, 2021, 145
  • [44] Five-repetition sit-to-stand test: End with the fifth stand or sit?
    Yamada, Minoru
    Lim, Jae-Young
    Assantachai, Prasert
    Tanaka, Tomoki
    Kim, Miji
    Lee, Sang Yoon
    Lim, Wee-Shiong
    Arai, Hidenori
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2022, 22 (04) : 362 - 364
  • [45] CLINICAL MEASUREMENT OF SIT TO STAND PERFORMANCE IN PEOPLE WITH HUNTINGTON'S DISEASE: RELIABILITY AND VALIDITY FOR 30 SECONDS CHAIR SIT TO STAND TEST
    Khalil, H.
    van Deursen, R.
    Quinn, L.
    Rosser, A.
    Busse, M.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2010, 81 : A28 - A28
  • [46] Reliability and validity of sit-to-stand test protocols in patients with coronary artery disease
    Wang, Zheng
    Yan, Jianhua
    Meng, Shu
    Li, Jiajia
    Yu, Yi
    Zhang, Tingting
    Tsang, Raymond C. C.
    El-Ansary, Doa
    Han, Jia
    Jones, Alice Y. M.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [47] Test-Retest Reliability and Minimal Detectable Change in Chester Step Test and 1-Minute Sit-to-Stand Test in Long COVID Patients
    Sevillano-Castano, Ana Isabel
    Peroy-Badal, Renata
    Torres-Castro, Rodrigo
    Canuelo-Marquez, Ana Maria
    Rozalen-Bustin, Manuel
    Modrego-Navarro, Angel
    De Sousa-De Sousa, Luis
    Ramos-Alvarez, Juan Jose
    Mate-Munoz, Jose Luis
    Garcia-Fernandez, Pablo
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [48] Teleassessment using five times sit-to-stand test in older adults with and without Parkinson's disease: Guidelines and barriers
    Figueiredo, Caroline Santos
    Pinto, Camila
    Bevilacqua, Isabela Possebon
    Cortez, Ivan Lima
    Pereira, Francisca
    do Pinho, Alexandre Severo
    Pagnussat, Aline Souza
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2024, 29 (04)
  • [49] Five times sit to stand test is a predictor of recurrent falls in healthy community-living subjects aged 65 and older
    Buatois, Severine
    Miljkovic, Darko
    Manckoundia, Patrick
    Gueguen, Rene
    Miget, Patrick
    Vancon, Guy
    Perrin, Philippe
    Benetos, Athanase
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2008, 56 (08) : 1575 - 1577
  • [50] Effects Of Dual Task On Five-times Sit-to-stand In Younger And Older Adults
    DeMarco, Deanna
    Meyer, Albert
    Alberto, Katey
    Wiltshire, Brandi
    Henderson, Sarah
    Chinworth, Susan
    Balasubramanian, Chitra
    Vallabhajosula, Srikant
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 398 - 398