This paper proposes a new method for detecting a driver's drowsiness from changes in the pulse rate of a finger. Electroencephalographic (EEG) signals were received from a sample of ten individuals. The analysis of electroencephalographic signals is investigated and the activation of theta waves during the drowsiness interval is observed. Photoplethysmography signals were received from ten participants simultaneously with the EEG signal. Finger pulse data are analyzed and the features showing a significant change during drowsiness in the pulse rate variability (PRV) of the finger are further identified and extracted. The results indicate that the values and the average values of PRV increase before the point of sleep onset (SO). It is observed that the standard deviation of all PP intervals (SDNN) has a significant reduction during drowsiness. An increase in the values of RMSSD is also observed in the drowsiness interval. Besides, the ratio of low to high frequency (LF/HF) representing the balance of sympathetic and parasympathetic branches decreases in the vicinity of SO which indicates raised parasympathetic activity. The nonlinear analysis of the Poincaré plot indicated the reduction of the SD1 parameter. The results indicate that the PRV method can be used for the detection of driver drowsiness. Finally, the presented method is considered in an intelligent steering wheel design as a feasible non-invasive procedure for the detection of driver drowsiness. © 2022, The Author(s), under exclusive licence to Springer Nature Singapore Pte Ltd.
引用
收藏
相关论文
共 50 条
  • [21] Improved Hypertension Detection Models Utilizing Pulse Rate Variability and Asymmetry
    Vraka, Aikaterini
    Facila, Lorenzo
    Hornero, Fernando
    Gracia-Baena, Juan M.
    Alcaraz, Raul
    Rieta, Jose J.
    ADVANCES IN DIGITAL HEALTH AND MEDICAL BIOENGINEERING, VOL 2, EHB-2023, 2024, 110 : 162 - 170
  • [22] Fusion of heart rate variability and pulse rate variability for emotion recognition using lagged poincare plots
    Goshvarpour, Atefeh
    Abbasi, Ataollah
    Goshvarpour, Ateke
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (03) : 617 - 629
  • [23] Fusion of heart rate variability and pulse rate variability for emotion recognition using lagged poincare plots
    Atefeh Goshvarpour
    Ataollah Abbasi
    Ateke Goshvarpour
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 617 - 629
  • [24] Detection of asphyxia using heart rate variability
    Boardman, A
    Schlindwein, FS
    Thakor, NV
    Kimura, T
    Geocadin, RG
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (06) : 618 - 624
  • [25] Detection of asphyxia using heart rate variability
    A. Boardman
    F. S. Schlindwein
    N. V. Thakor
    T. Kimura
    R. G. Geocadin
    Medical and Biological Engineering and Computing, 2002, 40 : 618 - 624
  • [26] Drowsiness Estimation Under Driving Environment by Heart Rate Variability and/or Breathing Rate Variability with Logistic Regression Analysis
    Igasaki, Tomohiko
    Nagasawa, Kazuki
    Murayama, Nobuki
    Hu, Zhencheng
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 189 - 193
  • [27] Study of Pulse Rate Variability Signals Using Bispectrum Analysis
    Zhang, Qingguang
    Yang, Jing
    Li, Liping
    Li, Bin
    Liu, Changchun
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [28] Pulse Rate Variability Analysis Using Remote Photoplethysmography Signals
    Yu, Su-Gyeong
    Kim, So-Eui
    Kim, Na Hye
    Suh, Kun Ha
    Lee, Eui Chul
    SENSORS, 2021, 21 (18)
  • [29] Analysis of a Pulse Rate Variability Measurement Using a Smartphone Camera
    Banhalmi, Andras
    Borbas, Janos
    Fidrich, Marta
    Bilicki, Vilmos
    Gingl, Zoltan
    Rudas, Laszlo
    JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
  • [30] Drowsiness Detection System Using Heartbeat Rate in Android-based Handheld Devices
    Ke, Kai-Wei
    Zulman, Muhammad R.
    Wu, Ho-Ting
    Huang, Yu-Fu
    Thiagarajan, Jayasakthi
    PROCEEDINGS 2016 FIRST INTERNATIONAL CONFERENCE ON MULTIMEDIA AND IMAGE PROCESSING (ICMIP 2016), 2016, : 99 - 103