Detection of Drowsiness Using the Pulse Rate Variability of Finger

被引:0
|
作者
Heydari S. [1 ]
Ayatollahi A. [1 ]
Najafi A. [2 ]
Poorjafari M. [1 ,3 ]
机构
[1] University of Science and Technology, Tehran
[2] Occupational Sleep Research Center, Baharloo Hospital, Tehran University of Medical Sciences, P.O. Box 1339973111, Tehran
[3] Highway and Transportation Engineering at Department of Civil Engineering, Iran University of Science and Technology, Tehran
关键词
Autonomous nervous system; Drowsiness; Photoplethysmography; Pulse rate variability;
D O I
10.1007/s42979-022-01247-1
中图分类号
学科分类号
摘要
This paper proposes a new method for detecting a driver's drowsiness from changes in the pulse rate of a finger. Electroencephalographic (EEG) signals were received from a sample of ten individuals. The analysis of electroencephalographic signals is investigated and the activation of theta waves during the drowsiness interval is observed. Photoplethysmography signals were received from ten participants simultaneously with the EEG signal. Finger pulse data are analyzed and the features showing a significant change during drowsiness in the pulse rate variability (PRV) of the finger are further identified and extracted. The results indicate that the values and the average values of PRV increase before the point of sleep onset (SO). It is observed that the standard deviation of all PP intervals (SDNN) has a significant reduction during drowsiness. An increase in the values of RMSSD is also observed in the drowsiness interval. Besides, the ratio of low to high frequency (LF/HF) representing the balance of sympathetic and parasympathetic branches decreases in the vicinity of SO which indicates raised parasympathetic activity. The nonlinear analysis of the Poincaré plot indicated the reduction of the SD1 parameter. The results indicate that the PRV method can be used for the detection of driver drowsiness. Finally, the presented method is considered in an intelligent steering wheel design as a feasible non-invasive procedure for the detection of driver drowsiness. © 2022, The Author(s), under exclusive licence to Springer Nature Singapore Pte Ltd.
引用
收藏
相关论文
共 50 条
  • [1] Drowsiness detection using heart rate variability
    José Vicente
    Pablo Laguna
    Ariadna Bartra
    Raquel Bailón
    Medical & Biological Engineering & Computing, 2016, 54 : 927 - 937
  • [2] Drowsiness detection using heart rate variability
    Vicente, Jose
    Laguna, Pablo
    Bartra, Ariadna
    Bailon, Raquel
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (06) : 927 - 937
  • [3] Drowsiness detection using heart rate variability analysis based on microcontroller unit
    Hendra, Muhammad
    Kurniawan, Danang
    Chrismiantari, Riza Vina
    Utomo, Trio Pambudi
    Nuryani, Nuryani
    9TH INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS (ICOPIA), 2019, 1153
  • [4] Detection of Driver Drowsiness Using Wavelet Analysis of Heart Rate Variability and a Support Vector Machine Classifier
    Li, Gang
    Chung, Wan-Young
    SENSORS, 2013, 13 (12) : 16494 - 16511
  • [5] Pulse Rate Variability Analysis by Video Using Face Detection and Tracking Algorithms
    Melchor Rodriguez, A.
    Ramos Castro, J.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5696 - 5699
  • [6] Heart Rate Variability-Based Driver Drowsiness Detection and Its Validation With EEG
    Fujiwara, Koichi
    Abe, Erika
    Kamata, Keisuke
    Nakayama, Chikao
    Suzuki, Yoko
    Yamakawa, Toshitaka
    Hiraoka, Toshihiro
    Kano, Manabu
    Sumi, Yukiyoshi
    Masuda, Fumi
    Matsuo, Masahiro
    Kadotani, Hiroshi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (06) : 1769 - 1778
  • [7] OSAS Detection in Children by using PPG Amplitude Fluctuation Decreases and Pulse Rate Variability
    Lazaro, Jesus
    Gil, Eduardo
    Maria Vergara, Jose
    Laguna, Pablo
    2012 COMPUTING IN CARDIOLOGY (CINC), VOL 39, 2012, 39 : 185 - 188
  • [8] Drowsiness Detection Based on Pulse Signal Sample Entropy
    Zhang Aihua
    Xu Wei
    2012 THIRD INTERNATIONAL CONFERENCE ON TELECOMMUNICATION AND INFORMATION (TEIN 2012), 2012, : 193 - 197
  • [9] Accuracy of pulse rate variability parameters obtained from finger plethysmogram: A comparison with heart rate variability parameters obtained from ECG
    Kageyama, T
    Kabuto, M
    Kaneko, T
    Nishikido, N
    JOURNAL OF OCCUPATIONAL HEALTH, 1997, 39 (02) : 154 - 155
  • [10] Detection of Drowsiness Using DCCNN
    Sravya, Raga K.
    Aparna, C. H.
    Pujitha, B.
    Krishnasai, N.
    2024 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATION AND APPLIED INFORMATICS, ACCAI 2024, 2024,