A three-dimensional non-contact measurement system

被引:0
|
作者
Shiuh-Jer Huang
Chi-Chan Lin
机构
[1] National Taiwan Institute of Technology,Department of Mechanical Engineering
关键词
Hough transform; Laser sensor; Three-dimensional measurement;
D O I
暂无
中图分类号
学科分类号
摘要
A simple three-dimensional (3D) non-contact measurement system was proposed which consisted of a 1D laser displacement sensor and a servo control coordinate system. The laser sensor was installed on theZ-axis perpendicular to theX, Y-holding table. A filter was designed to remove the noise in the measured data. An extraction technique of characteristic points was proposed to catch the edge data points of the measured objects. Then the Hough-transform technique of image processing was employed to calculate the position and dimension of the edge of measured objects based on the extracted characteristic points. The experimental results show that this simple structure can effectively measure the position and dimension of 3D objects with reasonable accuracy.
引用
收藏
页码:419 / 425
页数:6
相关论文
共 50 条
  • [31] Non-contact surface water conductivity measurement system
    Wang, Baoliang
    Xu, Shengji
    Ji, Haifeng
    Huang, Zhiyao
    Li, Haiqing
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2012, 33 (07): : 1620 - 1625
  • [32] Non-contact temperature measurement
    Metallurgia, 1995, 62 (02):
  • [33] NON-CONTACT SPEED MEASUREMENT
    KENYON, M
    VANHOEK, HC
    PORTER, CA
    AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1981, 37 (06): : 114 - 117
  • [34] PROGRESS IN NON-CONTACT MEASUREMENT
    LEWIS, GE
    CME-CHARTERED MECHANICAL ENGINEER, 1981, 28 (08): : 31 - 32
  • [35] Non-contact temperatures measurement
    Materiales de Construccion, 62 (238):
  • [36] NON-CONTACT MEASUREMENT BY RADIOACTIVITY
    BOND, A
    PROCESS ENGINEERING, 1975, (MAR) : 62 - 63
  • [37] Non-contact temperature measurement
    不详
    INDUSTRIAL CERAMICS, 2001, 21 (01): : 56 - 56
  • [38] Difference in the Maintenance Mechanism Between the Paroxysmal and Persistent Atrial Fibrillation: Three-dimensional Analysis Using a Non-contact Mapping System
    Kaneko, Shozo
    Yamabe, Hiroshige
    Kanazawa, Hisanori
    Ito, Miwa
    Kanemaru, Yusuke
    Kiyama, Takuya
    Ogawa, Hisao
    CIRCULATION, 2016, 134
  • [39] Non-contact scanning diffuse correlation tomography system for three-dimensional blood flow imaging in a murine bone graft model
    Han, Songfeng
    Johansson, Johannes
    Mireles, Miguel
    Proctor, Ashley R.
    Hoffman, Michael D.
    Vella, Joseph B.
    Benoit, Danielle S. W.
    Durduran, Turgut
    Choe, Regine
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (07): : 2695 - 2712
  • [40] Progress in enamel thickness measurement using a non-contact 3-dimensional measuring system
    Kono, R
    Sowa, G
    ANTHROPOLOGICAL SCIENCE, 1998, 106 (02) : 156 - 156