Miniaturized bimodal laser scanning microscopes

被引:0
|
作者
Yu J. [1 ]
Cai F. [1 ]
He S. [1 ]
机构
[1] Centre for Optical and Electromagnetic Research, Zhejiang Key Laboratory of Sensing Technologies, Zhejiang University, Hangzhou
来源
Journal of Optics (India) | 2015年 / 44卷 / 04期
基金
中国国家自然科学基金;
关键词
Bimodal imaging; Bio-imaging; Laser scanning microscope; Miniaturized;
D O I
10.1007/s12596-014-0229-2
中图分类号
学科分类号
摘要
In this paper, we report a miniaturized laser scanning microscope. Unlike conventional microscopes, the optical fiber used here for the excitation laser and signal’s transmission largely improves our microscope’s mobility, and thus eliminates the space constraints of the sample stage. This miniaturized microscope can be motorized along XYZ axis and rotated in theta direction. Based on this modified microscope, we take images of test targets and a micrometer, and compare the resolution and signal to background ratio between its confocal and non-descanned detection modules. We also present the imaging results of Hela cells on a tilted sample stage to simulate the imaging of large and irregular samples. Therefore, this miniaturized microscope has the potential to be utilized for in vivo imaging of large animals. © 2014, The Optical Society of India.
引用
收藏
页码:405 / 408
页数:3
相关论文
共 50 条
  • [41] Three-coordinate laser heterodyne interferometer for metrological assurance of scanning probe microscopes
    Kazieva, Tatiana V.
    Kuznetsov, Andrey P.
    Gubskiy, Konstantin L.
    Reshetov, Vladimir N.
    OPTICS AND MEASUREMENT CONFERENCE 2014, 2015, 9442
  • [42] Biological imaging using fast laser scanning heterodyne differential phase confocal microscopes
    Garside, JR
    Somekh, MG
    See, CW
    JOURNAL OF MICROSCOPY-OXFORD, 1997, 185 : 385 - 395
  • [43] Optimizing the performance of confocal point scanning laser microscopes over the full field of view
    Entwistle, A.
    Noble, M.
    Journal of Microscopy, 1994, 175 (03) : 238 - 251
  • [44] ON THE EQUIVALENCE OF SCANNING AND CONVENTIONAL MICROSCOPES.
    Sheppard, C.J.R.
    Wilson, T.
    Optik (Jena), 1986, 73 (01): : 39 - 43
  • [45] THE PERFORMANCE AND LIMITS OF SCANNING PROBE MICROSCOPES
    STEDMAN, M
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 347 - 352
  • [46] ENVIRONMENTAL SCANNING ELECTRON-MICROSCOPES
    LI, MJ
    ROGERS, K
    RUST, CA
    ADVANCED MATERIALS & PROCESSES, 1995, 148 (01): : 24 - 25
  • [47] DETECTOR ARRAYS IN CONFOCAL SCANNING MICROSCOPES
    WILSON, T
    SCANNING MICROSCOPY, 1990, 4 (01) : 21 - 24
  • [48] PHASE IMAGING IN SCANNING OPTICAL MICROSCOPES
    WILSON, T
    SHEPPARD, CJR
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1979, 69 (10) : 1443 - 1443
  • [49] IMPROVEMENT OF SCANNING ELECTRON-MICROSCOPES
    FETISOV, DV
    STEPANOV, SS
    YURCHENKO, GY
    GOLUBEV, VP
    POLYAKOV, VG
    POSTNIKOV, EB
    POCHTARE.BI
    KUSHNIR, YM
    GUROVA, RP
    MIKHAILOVA, OK
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1972, 36 (09): : 1860 - +
  • [50] OPTIMUM RECORDING CONDITIONS IN SCANNING MICROSCOPES
    DAMM, T
    WILHELMI, B
    JOURNAL OF MICROSCOPY-OXFORD, 1992, 165 : 71 - 80