Pigment-based whole-cell biosensor system for cadmium detection using genetically engineered Deinococcus radiodurans

被引:2
|
作者
Min-Ho Joe
Kang-Hee Lee
Sang-Yong Lim
Seong-Hun Im
Hyun-Pa Song
In Soo Lee
Dong-Ho Kim
机构
[1] Korea Atomic Energy Research Institute,Radiation Research Division for Biotechnology
[2] Hannam University,Department of Biotechnology
[3] Chonnam National University,Interdisciplinary Program of Graduate School for Bioenergy and Biomaterials
来源
关键词
Cadmium; Whole-cell biosensor; Macroscopic; Red pigment;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, a colorimetric whole-cell biosensor for cadmium (Cd) was designed using a genetically engineered red pigment producing bacterium, Deinococcus radiodurans. Based on the previous microarray data, putative promoter regions of highly Cd-inducible genes (DR_0070, DR_0659, DR_0745, and DR_2626) were screened and used for construction of lacZ reporter gene cassettes. The resultant reporter cassettes were introduced into D. radiodurans R1 to evaluate promoter activity and specificity. Among the promoters, the one derived from DR_0659 showed the highest specificity, sensitivity, and activity in response to Cd. The Cd-inducible activity was retained in the 393-bp deletion fragment (P0659-1) of the P0569 promoter, but the expression pattern of the putative promoter fragments inferred its complex regulation. The detection range was from 10 to 1 mM of Cd. The LacZ expression was increased up to 100 μM of Cd, but sharply decreased at higher concentrations. For macroscopic detection, the sensor plasmid (pRADI-P0659-1) containing crtI as a reporter gene under the control of P0659-1 was introduced into a crtI-deleted mutant strain of D. radiodurans (KDH018). The color of this sensor strain (KDH081) changed from light yellow to red by the addition of Cd and had no significant response to other metals. Color change by the red pigment synthesis could be clearly recognized in a day with the naked eye and the detection range was from 50 nM to 1 mM of Cd. These results indicate that genetically engineered D. radiodurans (KDH081) can be used to monitor the presence of Cd macroscopically.
引用
收藏
页码:265 / 272
页数:7
相关论文
共 50 条
  • [31] Development of whole-cell catalyst system for sulfide biotreatment based on the engineered haloalkaliphilic bacterium
    Manqi Zhang
    Qiong Xue
    Shengjie Zhang
    Heng Zhou
    Tong Xu
    Jian Zhou
    Yanning Zheng
    Ming Li
    Sumit Kumar
    Dahe Zhao
    Hua Xiang
    AMB Express, 11
  • [32] Transcription factor based whole-cell biosensor for specific and sensitive detection of sodium dodecyl sulfate
    Dey, Sourik
    Baba, Shahnawaz Ahmad
    Bhatt, Ankita
    Dhyani, Rajat
    Navani, Naveen Kumar
    BIOSENSORS & BIOELECTRONICS, 2020, 170
  • [33] Controllable detection threshold achieved through the toehold switch system in a mercury ion whole-cell biosensor
    Zhang, Qinglong
    Wei, Zixiang
    Jia, Xiaoqiang
    BIOSENSORS & BIOELECTRONICS, 2024, 256
  • [34] Development of a "turn off-on" whole-cell biosensor for sulforaphane detection based on the ultrasensitive activator HrpRS
    Li, Renjie
    Chen, Shengyan
    Li, Yangguang
    Chen, Xuan
    Ye, Bang-Ce
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2023, 70 (02) : 798 - 810
  • [35] Detection of 2,4-dichlorophenoxyacetic acid herbicide using a FGE-sulfatase based whole-cell Agrobacterium biosensor
    Ritcharoon, Benjarat
    Sallabhan, Ratiboot
    Toewiwat, Neal
    Mongkolsuk, Skorn
    Loprasert, Suvit
    JOURNAL OF MICROBIOLOGICAL METHODS, 2020, 175
  • [36] Air Quality Monitoring using a Whole-Cell based Sensor System
    Bohrn, U.
    Stuetz, E.
    Fuchs, K.
    Fleischer, M.
    Schoening, M. J.
    Wagner, P.
    EUROSENSORS XXV, 2011, 25
  • [37] High-throughput visualization mutation screening technology to enhance the specificity of CadR based whole-cell cadmium biosensor
    Guo, Mingzhang
    Chen, Shijing
    Su, Hongfei
    Chen, Xiaolin
    Liu, Huilin
    Sun, Baoguo
    BIOSENSORS & BIOELECTRONICS, 2024, 256
  • [38] A gas reporting whole-cell microbial biosensor system for rapid on-site detection of mercury contamination in soils
    Liu, Yanger
    Guo, Mingzhang
    Du, Ruoxi
    Chi, Jiani
    He, Xiaoyun
    Xie, Zixin
    Huang, Kunlun
    Luo, Yunbo
    Xu, Wentao
    BIOSENSORS & BIOELECTRONICS, 2020, 170
  • [39] Continuous, noninvasive monitoring of local microscopic inflammation using a genetically engineered cell-based biosensor
    Meng, YM
    Kasai, A
    Hiramatsu, N
    Hayakawa, K
    Yamauchi, K
    Takeda, M
    Kawachi, H
    Shimizu, F
    Yao, J
    Kitamura, M
    LABORATORY INVESTIGATION, 2005, 85 (11) : 1429 - 1439
  • [40] Whole-cell based label-free capacitive biosensor for rapid nanosize-dependent toxicity detection
    Qureshi, Anjum
    Pandey, Ashish
    Chouhan, Raghuraj S.
    Gurbuz, Yasar
    Niazi, Javed H.