Pigment-based whole-cell biosensor system for cadmium detection using genetically engineered Deinococcus radiodurans

被引:2
|
作者
Min-Ho Joe
Kang-Hee Lee
Sang-Yong Lim
Seong-Hun Im
Hyun-Pa Song
In Soo Lee
Dong-Ho Kim
机构
[1] Korea Atomic Energy Research Institute,Radiation Research Division for Biotechnology
[2] Hannam University,Department of Biotechnology
[3] Chonnam National University,Interdisciplinary Program of Graduate School for Bioenergy and Biomaterials
来源
关键词
Cadmium; Whole-cell biosensor; Macroscopic; Red pigment;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, a colorimetric whole-cell biosensor for cadmium (Cd) was designed using a genetically engineered red pigment producing bacterium, Deinococcus radiodurans. Based on the previous microarray data, putative promoter regions of highly Cd-inducible genes (DR_0070, DR_0659, DR_0745, and DR_2626) were screened and used for construction of lacZ reporter gene cassettes. The resultant reporter cassettes were introduced into D. radiodurans R1 to evaluate promoter activity and specificity. Among the promoters, the one derived from DR_0659 showed the highest specificity, sensitivity, and activity in response to Cd. The Cd-inducible activity was retained in the 393-bp deletion fragment (P0659-1) of the P0569 promoter, but the expression pattern of the putative promoter fragments inferred its complex regulation. The detection range was from 10 to 1 mM of Cd. The LacZ expression was increased up to 100 μM of Cd, but sharply decreased at higher concentrations. For macroscopic detection, the sensor plasmid (pRADI-P0659-1) containing crtI as a reporter gene under the control of P0659-1 was introduced into a crtI-deleted mutant strain of D. radiodurans (KDH018). The color of this sensor strain (KDH081) changed from light yellow to red by the addition of Cd and had no significant response to other metals. Color change by the red pigment synthesis could be clearly recognized in a day with the naked eye and the detection range was from 50 nM to 1 mM of Cd. These results indicate that genetically engineered D. radiodurans (KDH081) can be used to monitor the presence of Cd macroscopically.
引用
收藏
页码:265 / 272
页数:7
相关论文
共 50 条
  • [1] Pigment-based whole-cell biosensor system for cadmium detection using genetically engineered Deinococcus radiodurans
    Joe, Min-Ho
    Lee, Kang-Hee
    Lim, Sang-Yong
    Im, Seong-Hun
    Song, Hyun-Pa
    Lee, In Soo
    Kim, Dong-Ho
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2012, 35 (1-2) : 265 - 272
  • [2] Development of a pigment-based whole-cell biosensor for the analysis of environmental copper
    Chen, Pei-Hsuan
    Lin, Chieh
    Guo, Kai-Hong
    Yeh, Yi-Chun
    RSC ADVANCES, 2017, 7 (47): : 29302 - 29305
  • [3] Development of a Pigment-Based Whole-Cell Zinc Biosensor for Human Serum
    Watstein, Daniel M.
    Styczynski, Mark P.
    ACS SYNTHETIC BIOLOGY, 2018, 7 (01): : 267 - 275
  • [4] Genetic control of violacein biosynthesis to enable a pigment-based whole-cell lead biosensor
    Hui, Chang-ye
    Guo, Yan
    Liu, Lisa
    Zhang, Nai-xing
    Gao, Chao-xian
    Yang, Xue-qin
    Yi, Juan
    RSC ADVANCES, 2020, 10 (47) : 28106 - 28113
  • [5] A genetically engineered whole-cell pigment-based bacterial biosensing system for quantification of N-butyryl homoserine lactone quorum sensing signal
    Yong, Yang-Chun
    Zhong, Jian-Jiang
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (01): : 41 - 47
  • [6] Hydroxylated polychlorinated biphenyl detection based on a genetically engineered bioluminescent whole-cell sensing system
    Turner, Kendrick
    Xu, Shifen
    Pasini, Patrizia
    Deo, Sapna
    Bachas, Leonidas
    Daunert, Sylvia
    ANALYTICAL CHEMISTRY, 2007, 79 (15) : 5740 - 5745
  • [7] Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein
    Zhang, Juan
    Guo, Yan
    Lin, Yi-ran
    Ma, Bing-chan
    Ge, Xue-ru
    Zhang, Wen-qi
    Zhang, Nai-xing
    Yang, Shu-man
    Hui, Chang-ye
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2024, 10 (06): : 4046 - 4058
  • [8] Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
    Zhang, Guangbao
    Hu, Shuting
    Jia, Xiaoqiang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [9] An efficient design strategy for a whole-cell biosensor based on engineered ribosome binding sequences
    Qing Yu
    Yan Li
    Anzhou Ma
    Weifeng Liu
    Hailin Wang
    Guoqiang Zhuang
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2891 - 2898
  • [10] An engineered quorum-sensing-based whole-cell biosensor for active degradation of organophosphates
    He, Jianwei
    Zhang, Xiaoyan
    Qian, Yuanyi
    Wang, Qiyao
    Bai, Yunpeng
    BIOSENSORS & BIOELECTRONICS, 2022, 206