Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin

被引:0
|
作者
Eda Mehmeti
Dalibor M. Stanković
Sudkate Chaiyo
Ľubomir Švorc
Kurt Kalcher
机构
[1] Institute of Chemistry,Department of Analytical Chemistry, Innovation Center of the Faculty of Chemistry
[2] Analytical Chemistry,Electrochemistry and Optical Spectroscopy Research Unit, Department of Chemistry, Faculty of Science
[3] Karl-Franzens University,undefined
[4] University of Belgrade,undefined
[5] Chulalongkorn University,undefined
[6] Institute of Analytical Chemistry,undefined
[7] Faculty of Chemical and Food Technology,undefined
[8] Slovak University of Technology in Bratislava,undefined
来源
Microchimica Acta | 2016年 / 183卷
关键词
Differential pulse voltammetry; Cyclic voltammetry; Vitamin B; Electrooxidation;
D O I
暂无
中图分类号
学科分类号
摘要
A carbon paste electrode bulk was modified with MnO2 and investigated for use as an electrochemical sensor for riboflavin (vitamin B2) using differential pulse voltammetry (DPV). Riboflavin displays a well expressed oxidation peak at −0.15 V (versus Ag/AgCl) in solutions with a pH value of 2. Effects of pH value, pulse amplitude and pulse time were optimized by employing DPV. The signals obtained are linearly related to the concentrations of riboflavin in the range from 0.02 to 9 μM. Other features include a 15 nM detection limit, and good reproducibility (±3 %) and repeatability (±2 %). Interferences by common compounds were tested, and the method was successfully applied to the determination of riboflavin in pharmaceutical formulations where is gave recoveries in the range from 95 to 97 %.
引用
收藏
页码:1619 / 1624
页数:5
相关论文
共 50 条
  • [11] Voltammetric determination of mifepristone at a DNA-modified carbon paste electrode
    K. Gu
    J. Zhu
    Y. Zhu
    J. Xu
    H.-Y. Chen
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 832 - 835
  • [12] VOLTAMMETRIC DETERMINATION OF GOLD USING A CARBON PASTE ELECTRODE MODIFIED WITH THIOBENZANILIDE
    CAI, XH
    KALCHER, K
    NEUHOLD, C
    DIEWALD, W
    MAGEE, RJ
    ANALYST, 1993, 118 (01) : 53 - 57
  • [13] MODIFIED CARBON-PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF TRACE SILICON
    GURENTSOVA, OI
    PROKHOROVA, GV
    OSIPOVA, EA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (09) : 1224 - 1228
  • [14] Voltammetric determination terbinafine at carbon paste electrode modified with graphene nanosheets
    Hendawy, Hassan A. M.
    Radowan, Abdellatef A.
    Khaled, Elmorsy
    EGYPTIAN JOURNAL OF CHEMISTRY, 2023, 66 (03): : 103 - 112
  • [15] VOLTAMMETRIC DETERMINATION OF LINURON AT A CARBON-PASTE ELECTRODE MODIFIED WITH SEPIOLITE
    HERNANDEZ, P
    VICENTE, J
    GONZALEZ, M
    HERNANDEZ, L
    TALANTA, 1990, 37 (08) : 789 - 794
  • [16] VOLTAMMETRIC DETERMINATION OF CADMIUM ON A CARBON PASTE ELECTRODE MODIFIED WITH A CHELATING RESIN
    AGRAZ, R
    SEVILLA, MT
    PINILLA, JM
    HERNANDEZ, L
    ELECTROANALYSIS, 1991, 3 (4-5) : 393 - 397
  • [17] Voltammetric determination of mifepristone at a DNA-modified carbon paste electrode
    Gu, K
    Zhu, JJ
    Zhu, YL
    Xu, JZ
    Chen, HY
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (08): : 832 - 835
  • [18] Electrochemical Behavior and Voltammetric Determination of a Manganese(II) Complex at a Carbon Paste Electrode
    Karastogianni, Sophia
    Girousi, Stella
    ANALYTICAL CHEMISTRY INSIGHTS, 2016, 11 : 1 - 11
  • [19] Voltammetric determination of azithromycin at the carbon paste electrode
    Farghaly, OA
    Mohamed, NAL
    TALANTA, 2004, 62 (03) : 531 - 538
  • [20] Flow injection determination of hydrogen peroxide using a carbon paste electrode modified with a manganese dioxide film
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    ANALYTICAL LETTERS, 1997, 30 (15) : 2655 - 2673