Development of Ta-based STJ X-ray Detector Arrays for Synchrotron Science

被引:0
|
作者
M. H. Carpenter
S. Friedrich
J. A. Hall
J. Harris
R. Cantor
机构
[1] STAR Cryoelectronics,Department of Applied Science
[2] University of California,undefined
[3] Lawrence Livermore National Laboratory,undefined
[4] XIA LLC,undefined
来源
关键词
X-ray absorption spectroscopy; X-ray detectors; Superconducting tunnel junctions; Adiabatic demagnetization refrigerator;
D O I
暂无
中图分类号
学科分类号
摘要
We are developing a cryogen-free Ta-based superconducting tunnel junction (STJ) detector for soft X-ray spectroscopy at synchrotrons. With an energy resolution 10 times higher than conventional solid-state X-ray detectors and count-rate capabilities above 5 kHz/pixel, STJ detectors offer potentially increased sensitivity for fluorescence-yield X-ray absorption spectroscopy (FY-XAS). We have developed 36-pixel arrays of 208 ×\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\times $$\end{document} 208 μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu $$\end{document}m Ta STJs with an energy resolution of ∼\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sim $$\end{document}9 eV FWHM at the 525 eV oxygen K line. Compared to earlier Nb-based STJs, Ta-STJs offer improved energy resolution and absorption efficiency and extend the operating range to several keV. Here we describe the integration of the 36-pixel arrays into a cryogen-free, user-friendly X-ray spectrometer. A computer-controlled adiabatic demagnetization refrigerator coupled to a two-stage pulse tube refrigerator allows operation below 100 mK. The detector chip is located at the end of a 42 cm shielded snout for insertion into the analysis chamber. The system is currently being commissioned at the Advanced Light Source synchrotron.
引用
收藏
页码:222 / 227
页数:5
相关论文
共 50 条
  • [31] STJ X-ray detectors with killed electrode
    Andrianov, VA
    Dmitriev, PN
    Koshelets, VP
    Kozin, MG
    Romashkina, IL
    Sergeev, SA
    LOW TEMPERATURE DETECTORS, 2002, 605 : 161 - 164
  • [32] 112-Pixel Arrays of High-Efficiency STJ X-Ray Detectors
    Friedrich, S.
    Harris, J.
    Warburton, W. K.
    Carpenter, M. H.
    Hall, J. A.
    Cantor, R.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (3-4) : 553 - 559
  • [33] Matrix-addressed x-ray detector arrays
    Street, RA
    Apte, R
    Boyce, JB
    Ho, J
    Lau, R
    Lemmi, F
    Lu, JP
    Mulato, M
    Ready, SE
    VanSchuylenbergh, K
    HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 263 - 273
  • [34] Detector Development for X-ray Imaging
    Mentzer, M. A.
    Herr, D. A.
    Brewer, K. J.
    Ojason, N.
    Tarpine, H. A.
    OPTICAL COMPONENTS AND MATERIALS VII, 2010, 7598
  • [35] Development of a prototype X-ray detector, using mono crystalline Nb and Ta absorbers
    Hamster, AW
    Webers, JMA
    Kachlicki, T
    Wormeester, H
    Flokstra, J
    Rogalla, H
    van den Berg, ML
    Bruijn, MP
    Kiewiet, FB
    Luiten, OJ
    de Korte, PAJ
    APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2: VOL 1: SMALL SCALE AND ELECTRONIC APPLICATIONS; VOL 2: LARGE SCALE AND POWER APPLICATIONS, 1997, (158): : 425 - 428
  • [36] STJ X-ray detectors with titanium sublayer
    Kozin, MG
    Romashkina, IL
    Sergeev, SA
    Nefedov, LV
    Andrianov, VA
    Naumkin, VN
    Koshelets, VP
    Filippenko, LV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 250 - 253
  • [37] Synchrotron science - X-ray pulses chopped to femtoseconds
    Service, RF
    SCIENCE, 2000, 287 (5461) : 2130 - 2131
  • [38] Actinide science with soft x-ray synchrotron radiation
    Shuh, DK
    PLUTONIUM FUTURES-THE SCIENCE, 2000, 532 : 67 - 68
  • [39] Development of an x-ray polarimeter at the SOLEIL synchrotron
    Manzanillas, L.
    Ablett, J. M.
    Choukroun, M.
    Iguaz, F. J.
    Rueff, J. -P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (05):
  • [40] A multiple CCD X-ray detector and its first operation with synchrotron radiation X-ray beam
    Suzuki, M
    Yamamoto, M
    Kumasaka, T
    Sato, K
    Toyokawa, H
    Aries, IF
    Jerram, PA
    Ueki, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 174 - 181