Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients

被引:0
|
作者
François Pontana
Alain Duhamel
Julien Pagniez
Thomas Flohr
Jean-Baptiste Faivre
Anne-Lise Hachulla
Jacques Remy
Martine Remy-Jardin
机构
[1] University Lille Nord de France,Department of Thoracic Imaging, Hospital Calmette (EA 2694)
[2] University Lille Nord de France,Department of Medical Statistics
[3] Computed Tomography Division,Department of Thoracic Imaging
[4] Siemens Healthcare,undefined
[5] Hospital Calmette,undefined
来源
European Radiology | 2011年 / 21卷
关键词
Radiation dose; CT; Chest; Iterative reconstruction; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:636 / 643
页数:7
相关论文
共 50 条
  • [31] Superior objective and subjective image quality of deep learning reconstruction for low-dose abdominal CT imaging in comparison with model-based iterative reconstruction and filtered back projection
    Tamura, Akio
    Mukaida, Eisuke
    Ota, Yoshitaka
    Kamata, Masayoshi
    Abe, Shun
    Yoshioka, Kunihiro
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1123):
  • [32] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    So Won Lee
    Yookyung Kim
    Sung Shine Shim
    Jeong Kyong Lee
    Seok Jeong Lee
    Yon Ju Ryu
    Jung Hyun Chang
    European Radiology, 2014, 24 : 817 - 826
  • [33] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    Lee, So Won
    Kim, Yookyung
    Shim, Sung Shine
    Lee, Jeong Kyong
    Lee, Seok Jeong
    Ryu, Yon Ju
    Chang, Jung Hyun
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 817 - 826
  • [34] Low-Dose Computed Tomographic Urography Using Adaptive Iterative Dose Reduction 3-Dimensional: Comparison With Routine-Dose Computed Tomography With Filtered Back Projection
    Juri, Hiroshi
    Matsuki, Mitsuru
    Inada, Yuki
    Tsuboyama, Takahiro
    Kumano, Seishi
    Azuma, Haruhito
    Narumi, Yoshifumi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 426 - 431
  • [35] Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality
    Afadzi, Mercy
    Lysvik, Elisabeth Kirkeby
    Andersen, Hilde Kjernlie
    Martinsen, Anne Catrine T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 62 - 68
  • [36] Comparison of applied dose and image quality in staging CT of neuroendocrine tumor patients using standard filtered back projection and adaptive statistical iterative reconstruction
    Boening, G.
    Schaefer, M.
    Grupp, U.
    Kaul, D.
    Kahn, J.
    Pavel, M.
    Maurer, M.
    Denecke, T.
    Hamm, B.
    Streitparth, F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) : 1601 - 1607
  • [37] CT of Urolithiasis: Comparison of Image Quality and Diagnostic Confidence Using Filtered Back Projection and Iterative Reconstruction Techniques
    Hansmann, Jan
    Schoenberg, Gita M.
    Brix, Gunnar
    Henzler, Thomas
    Meyer, Mathias
    Attenberger, Ulrike I.
    Schoenberg, Stefan O.
    Fink, Christian
    ACADEMIC RADIOLOGY, 2013, 20 (09) : 1162 - 1167
  • [38] Image Quality in the Slice-Plane of Half-Reconstructed Computed Tomography in Filtered Back Projection and Iterative Reconstruction Methods
    Tsuda, N.
    Mitsui, K.
    Oda, S.
    Tanaka, N.
    Aibe, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E538 - E539
  • [39] The effect of a pre-reconstruction process in a filtered back projection reconstruction on an image quality of a low tube voltage computed tomography
    Takemitsu, Masaki
    Kudomi, Shohei
    Takegami, Kazuki
    Uehara, Takuya
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 306 - 314
  • [40] The effect of a pre-reconstruction process in a filtered back projection reconstruction on an image quality of a low tube voltage computed tomography
    Masaki Takemitsu
    Shohei Kudomi
    Kazuki Takegami
    Takuya Uehara
    Radiological Physics and Technology, 2024, 17 : 306 - 314