In vitro comparison of steady and pulsatile flow characteristics of jellyfish heart valve

被引:0
|
作者
Morsi Y.S. [1 ]
机构
[1] Bio-fluid Dynamics Group, School of Engineering and Science, Swinburne University of Technology, Hawthorn
关键词
Aortic valves; Jellyfish heart valve; Prosthetic valve; Pulsatile flow; Steady flow;
D O I
10.1007/BF02479981
中图分类号
学科分类号
摘要
In examining the hydrodynamic performance of artificial heart valves in vitro, experiments are carried out under either steady or pulsatile flow conditions. Steady flow experiments are simple to set up and analysis of the data is also simple; however, their validity and accuracy have been questioned. In this study, the flow characteristics of jellyfish valves are evaluated and analyzed for steady and pulsatile flow conditions. The analysis is given in terms of velocity and shear stress distributions for a cardiac flow rate of 4.51/min, and the corresponding steady flow rate is measured at two locations, 0.5D and 1D downstream of the valve face (D being the diameter of the pipe). At the 0.5D location, the velocity profile results obtained for both flow conditions indicated that jetting flow occurred close to the wall, and flow reversal as well as stagnation zones occurred in the core of the valve chamber. These phenomena were also evident in the shear stress profiles for both pulsatile and steady flow conditions. At this location, the maximum difference between the steady and pulsatile values of peak velocity is about 18%. However, the maximum difference between the peak shear stresses was in the range of 5%-7%. At the 1D location, the flow characteristics observed under both the pulsatile and steady flow conditions were almost identical, with a maximum difference between the peak values of less than 4%. From the data presented here, it can be stated that, at least in the initial optimization of the valve hemodynamic performance, the steady hydrodynamic evaluation of the valve could be an effective tool for analyzing the flow characteristics.
引用
收藏
页码:143 / 148
页数:5
相关论文
共 50 条
  • [21] In vitro flow analysis of artificial heart valve
    Owida, AA
    Morsi, Y
    Sakhaeimanesh, A
    COMPUTATIONAL MECHANICS, VOLS 1 AND 2, PROCEEDINGS: NEW FRONTIERS FOR THE NEW MILLENNIUM, 2001, : 893 - 898
  • [22] In vitro laser Doppler anemometry of pulsatile flow velocity and shear stress measurements downstream from a jellyfish valve in the mitral position of a ventricular assist device
    Morsi Y.
    Kogure M.
    Umezu M.
    Journal of Artificial Organs, 1999, 2 (1) : 62 - 73
  • [23] PULSATILE FLOW CHARACTERISTICS OF AORTIC-VALVE PORCINE HETEROGRAFTS IN MAN
    CHRISTIE, LG
    NICHOLS, WW
    PEPINE, CJ
    CURRY, RC
    CONTI, CR
    CIRCULATION, 1978, 58 (03) : 162 - 165
  • [24] PULSATILE FLOW CHARACTERISTICS OF AORTIC-VALVE PORCINE HETEROGRAFTS IN MAN
    CHRISTIE, LG
    NICHOLS, WW
    PEPINE, CJ
    CURRY, RC
    CONTI, CR
    CIRCULATION, 1977, 56 (04) : 131 - 131
  • [25] IN VITRO STUDY OF THE INFLUENCE OF THE AORTIC ROOT GEOMETRY ON FLOW CHARACTERISTICS OF A PROSTHETIC HEART VALVE
    Barannyk, Oleksandr
    Karri, Satya
    Oshkai, Peter
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2013, VOL 4: FLUID-STRUCTURE INTERACTION, 2014,
  • [26] IN VITRO STUDY OF PULSATILE FLOW THROUGH A MOTIONLESS DIODE VALVE IN THE PULMONARY POSITION
    Camp, Tiffany A.
    Figliola, Richard
    Beasley, Donald
    Conover, Timothy
    McQuinn, Tim
    Hsia, T-Y
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 423 - 424
  • [27] Analysis of Steady and Physiological Pulsatile Flow Characteristics in an Artery with Various Percentages of Restrictions
    Goswami, P.
    Mandal, D. K.
    Manna, N. K.
    Chakrabarti, S.
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2015, 42 (03) : 260 - 280
  • [28] Three dimensional ultrasound flow imaging of the proximal flow convergence region: In vitro studies on steady and pulsatile flow
    Shandas, R
    Knudson, O
    Kwon, J
    ValdesCruz, L
    CIRCULATION, 1996, 94 (08) : 421 - 421
  • [29] FLOW CHARACTERISTICS OF MENISCUS PROSTHETIC HEART VALVE
    CRUZ, AB
    KASTER, RL
    SIMMONS, RL
    LILLEHEI, CW
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1965, 49 (05): : 813 - &
  • [30] Flow characteristics past jellyfish and St. Vincent valves in the aortic position under physiological pulsatile flow conditions
    Morsi, YS
    Sakhaeimanesh, AA
    ARTIFICIAL ORGANS, 2000, 24 (07) : 564 - 574