Effect of Bolus Volume and Viscosity on Pharyngeal Automated Impedance Manometry Variables Derived for Broad Dysphagia Patients

被引:0
|
作者
Taher I. Omari
Eddy Dejaeger
Jan Tack
Dirk Van Beckevoort
Nathalie Rommel
机构
[1] Women’s and Children’s Health Network,Gastroenterology Unit
[2] University of Adelaide,School of Paediatrics and Reproductive Health
[3] University Hospital Leuven,Geriatric Medicine
[4] University of Leuven,Translational Research Center for Gastrointestinal Diseases
[5] University Hospital Leuven,Department of Radiology
[6] University of Leuven,Department of Neurosciences, ExpORL
[7] Children,Gastroenterology Unit
[8] Youth & Women’s Health Service,undefined
来源
Dysphagia | 2013年 / 28卷
关键词
Respiratory aspiration; Deglutition disorders; Manometry; Electric impedance; Deglutition;
D O I
暂无
中图分类号
学科分类号
摘要
Automated impedance manometry (AIM) analysis measures swallow variables defining bolus timing, pressure, contractile vigour, and bolus presence, which are combined to derive a swallow risk index (SRI) correlating with aspiration. In a heterogeneous cohort of dysphagia patients, we assessed the impact of bolus volume and viscosity on AIM variables. We studied 40 patients (average age = 46 years). Swallowing of boluses was recorded with manometry, impedance, and videofluoroscopy. AIMplot software was used to derive functional variables: peak pressure (PeakP), pressure at nadir impedance (PNadImp), time from nadir impedance to peak pressure (TNadImp-PeakP), the interval of impedance drop in the distal pharynx (flow interval, FI), upper oesophageal sphincter (UES) relaxation interval (UES RI), nadir UES pressure (Nad UESP), UES intrabolus pressure (UES IBP), and UES resistance. The SRI was derived using the formula SRI = (FI * PNadImp)/(PeakP * (TNadImp-PeakP + 1)) * 100. A total of 173 liquid, 44 semisolid, and 33 solid boluses were analysed. The SRI was elevated in relation to aspiration. PeakP increased with volume. SRI was not significantly altered by bolus volume. PNadImp, UES IBP, and UES resistance increased with viscosity. SRI was lower with increased viscosity. In patients with dysphagia, the SRI is elevated in relation to aspiration, reduced by bolus viscosity, and not affected by bolus volume. These data provide evidence that pharyngeal AIM analysis may have clinical utility for assessing deglutitive aspiration risk to liquid boluses.
引用
收藏
页码:146 / 152
页数:6
相关论文
共 32 条
  • [21] High-resolution impedance manometry for comparing bolus transit between patients with non-obstructive dysphagia and asymptomatic controls
    Cha, Boram
    Choi, Kyungmin
    Jung, Kee Wook
    Kim, Hwa Jung
    Kim, Ga Hee
    Na, Hee Kyong
    Ahn, Ji Yong
    Lee, Jeong Hoon
    Choi, Kee Don
    Kim, Do Hoon
    Song, Ho June
    Lee, Gin Hyug
    Jung, Hwoon-Yong
    Joo, Segyeong
    NEUROGASTROENTEROLOGY AND MOTILITY, 2023, 35 (04):
  • [22] Increased Bolus Volume Effect on Delayed Pharyngeal Swallowing Response in Post-stroke Oropharyngeal Dysphagia: A Pilot Study
    Park, Jin-Woo
    Sim, Gyu-Jeong
    Yang, Dong-Chan
    Lee, Kyoung-Hwan
    Chang, Ji-Hea
    Nam, Ki-Yeun
    Lee, Ho-Jun
    Kwon, Bum-Sun
    ANNALS OF REHABILITATION MEDICINE-ARM, 2016, 40 (06): : 1018 - 1023
  • [23] Automated impedance-manometry analysis detects esophageal motor dysfunction in patients who have non-obstructive dysphagia with normal manometry
    Nguyen, N. Q.
    Holloway, R. H.
    Smout, A. J.
    Omari, T. I.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 (03): : 238 - +
  • [24] Automated High Resolution Impedance Manometry Analysis Detects Esophageal Motor Dysfunction in Patients Who Have Non-Obstructive Dysphagia With Normal Manometry
    Nguyen, Nam Q.
    Singendonk, Maartje
    Burgess, Jenna E.
    Tippett, Marcus
    Holloway, Richard H.
    Omari, Taher
    GASTROENTEROLOGY, 2016, 150 (04) : S44 - S44
  • [25] Automated high resolution impedance manometry analysis detects esophageal motor dysfunction in patients who have non-obstructive dysphagia with normal manometry
    Nguyen, N. Q.
    Singendonk, M. J.
    Burgess, J. E.
    Tippett, M.
    Holloway, R.
    Omari, T. I.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2015, 30 : 152 - 152
  • [26] Automated High-Resolution Impedance Manometry Analysis Detects Subtle Esophageal Motor Dysfunction in Patients Who Have Non-Obstructive Dysphagia With Normal Manometry/Impedance Study
    Nguyen, Nam Q.
    Singendonk, Maartje M.
    Myers, Jennifer C.
    Tippett, Marcus
    Bambrick, Jenna E.
    Holloway, Richard H.
    Omari, Taher
    GASTROENTEROLOGY, 2014, 146 (05) : S685 - S686
  • [27] Inter-Swallow Variability Assessed by Means of Automated Impedance Manometry Is Different in Patients With Oropharyngeal Dysphagia Compared to Healthy Volunteers
    Liesenborghs, Claudia
    Scheerens, Charlotte
    Selleslagh, Margot
    Dejaeger, Eddy W.
    Omari, Taher
    Tack, Jan F.
    Rommel, Nathalie
    GASTROENTEROLOGY, 2014, 146 (05) : S894 - S894
  • [28] Effect of Bolus Viscosity on the Safety and Efficacy of Swallowing and the Kinematics of the Swallow Response in Patients with Oropharyngeal Dysphagia: White Paper by the European Society for Swallowing Disorders (ESSD)
    Roger Newman
    Natàlia Vilardell
    Pere Clavé
    Renée Speyer
    Dysphagia, 2016, 31 : 232 - 249
  • [29] Effect of Bolus Viscosity on the Safety and Efficacy of Swallowing and the Kinematics of the Swallow Response in Patients with Oropharyngeal Dysphagia: White Paper by the European Society for Swallowing Disorders (ESSD)
    Newman, Roger
    Vilardell, Natalia
    Clave, Pere
    Speyer, Renee
    DYSPHAGIA, 2016, 31 (02) : 232 - 249
  • [30] Erratum to: Effect of Bolus Viscosity on the Safety and Efficacy of Swallowing and the Kinematics of the Swallow Response in Patients with Oropharyngeal Dysphagia: White Paper by the European Society for Swallowing Disorders (ESSD)
    Roger Newman
    Natàlia Vilardell
    Pere Clavé
    Renée Speyer
    Dysphagia, 2016, 31 : 719 - 719