Computer-Aided Detection of Intracranial Aneurysms in MR Angiography

被引:0
|
作者
Xiaojiang Yang
Daniel J. Blezek
Lionel T. E. Cheng
William J. Ryan
David F. Kallmes
Bradley J. Erickson
机构
[1] Mayo Clinic,
[2] Medical Imaging Informatics Innovation Center,undefined
[3] Mayo Clinic,undefined
[4] Department of Radiology,undefined
[5] Mayo Clinic,undefined
[6] College of Medicine,undefined
来源
Journal of Digital Imaging | 2011年 / 24卷
关键词
Computer-aided detection (CAD); magnetic resonance angiography (MRA); intracranial aneurysm; aneurysm detection;
D O I
暂无
中图分类号
学科分类号
摘要
Intracranial aneurysms represent a significant cause of morbidity and mortality. While the risk factors for aneurysm formation are known, the detection of aneurysms remains challenging. Magnetic resonance angiography (MRA) has recently emerged as a useful non-invasive method for aneurysm detection. However, even for experienced neuroradiologists, the sensitivity to small (<5 mm) aneurysms in MRA images is poor, on the order of 30~60% in recent, large series. We describe a fully automated computer-aided detection (CAD) scheme for detecting aneurysms on 3D time-of-flight (TOF) MRA images. The scheme locates points of interest (POIs) on individual MRA datasets by combining two complementary techniques. The first technique segments the intracranial arteries automatically and finds POIs from the segmented vessels. The second technique identifies POIs directly from the raw, unsegmented image dataset. This latter technique is useful in cases of incomplete segmentation. Following a series of feature calculations, a small fraction of POIs are retained as candidate aneurysms from the collected POIs according to predetermined rules. The CAD scheme was evaluated on 287 datasets containing 147 aneurysms that were verified with digital subtraction angiography, the accepted standard of reference for aneurysm detection. For two different operating points, the CAD scheme achieved a sensitivity of 80% (71% for aneurysms less than 5 mm) with three mean false positives per case, and 95% (91% for aneurysms less than 5 mm) with nine mean false positives per case. In conclusion, the CAD scheme showed good accuracy and may have application in improving the sensitivity of aneurysm detection on MR images.
引用
收藏
页码:86 / 95
页数:9
相关论文
共 50 条
  • [41] Reproducibility in mammographic computer-aided detection
    Worrell, S
    Collins, M
    Mitchell, R
    Hoffmeister, JW
    Bauer, K
    Rogers, SK
    Kabrisky, M
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 1042 - 1042
  • [42] Computer-aided detection of breast cancer
    Milne, NC
    RADIOLOGY, 2004, 233 (02) : 615 - 616
  • [43] Computer-aided detection for screening mammography
    Astley, SM
    ACADEMIC RADIOLOGY, 2004, 11 (10) : 1139 - 1143
  • [44] Computer-aided detection: There is no free lunch
    D'Orsi, CJ
    RADIOLOGY, 2001, 221 (03) : 585 - 586
  • [45] Computer-aided detection of breast cancer
    不详
    EUROPEAN JOURNAL OF CANCER, 2008, 44 (17) : 2536 - 2536
  • [46] Computer-aided detection for screening mammography
    Astley, SM
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 927 - 932
  • [47] On Combining Computer-Aided Detection Systems
    Niemeijer, Meindert
    Loog, Marco
    Abramoff, Michael David
    Viergever, Max A.
    Prokop, Mathias
    van Ginneken, Bram
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 215 - 223
  • [48] Breast imaging and computer-aided detection
    Hall, Ferris M.
    NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (14): : 1464 - 1466
  • [49] Computer-Aided Detection for CT Colonography
    徐嫣然
    赵俊
    Journal of Shanghai Jiaotong University(Science), 2014, 19 (05) : 531 - 537
  • [50] Performance of mammographic computer-aided detection
    Collins, M
    Mitchell, R
    Worrell, S
    Hoffmeister, JW
    Bauer, K
    Rogers, SK
    Kabrisky, M
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 1041 - 1041