High-porosity expanded polytetrafluoroethylene grafts for thoracic vena cava replacement with or without an omentum wrap

被引:0
|
作者
Toshiya Nishibe
Keishu Yasuda
Hideki Ohkashiwa
Satoshi Watanabe
Yasuhiro Okuda
Tatsuzo Tanabe
机构
[1] Hokkaido University School of Medicine,Department of Cardiovascular Surgery
[2] Hokkaido University School of Medicine,Second Department of Surgery
[3] Hokkaido University School of Medicine,Department of Anatomy, Graduate School
[4] Sumitomo Electric Industries,Biomedical Research and Development Department
[5] Co.,undefined
[6] Ltd.,undefined
[7] Sapporo General Hospital of Nippon Telegraph and Telephone Corp.,undefined
来源
Surgery Today | 2000年 / 30卷
关键词
High-porosity polytetrafluoroethylene graft; Omentum wrap; Thoracic inferior vena cava reconstruction;
D O I
暂无
中图分类号
学科分类号
摘要
We previously reported that, in a short-term thoracic inferior vena cava (IVC) replacement, a highporosity expanded polytetrafluoroethylene (ePTFE) graft (fibril length 60μm) performed well without altering the short-term patency, and that the healing of the high-porosity ePTFE graft was accelerated by an omentum wrap. The purpose of this study was to examine the long-term performance of the high-porosity ePTFE graft with or without an omentum wrap. Eighteen grafts were placed as a thoracic IVC replacement in dogs. Nine of the grafts were wrapped in an omental pedicle flap while the other 9 were not. At 1 month and 6 months, the grafts were harvested and examined for a pathological analysis. During the observation period, one dog died of a viral infection, while the other 17 dogs survived. At 1 month and 6 months, the patency rates of the 17 grafts were 100% regardless of the presence or absence of an omentum wrap. The healing of the grafts without omentum wrap was incomplete 6 months after implantation; granulation tissue was present in the center of the pseudointima. The grafts healed completely by the addition of an omentum wrap. Our data suggest that, with an omentum wrap, the high-porosity ePTFE graft is fully expected to show a good long-term function.
引用
收藏
页码:631 / 635
页数:4
相关论文
共 24 条
  • [11] Surgical Outcomes after Superior Vena Cava Reconstruction with Expanded Polytetrafluoroethylene Grafts
    Nakano, Tomoyuki
    Endo, Shunsuke
    Kanai, Yoshihiko
    Otani, Shinichi
    Tsubochi, Hiroyoshi
    Yamamoto, Shinichi
    Tetsuka, Kenji
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 (04) : 310 - 315
  • [12] CONVENTIONAL VERSUS HIGH-POROSITY POLYTETRAFLUOROETHYLENE GRAFTS - CLINICAL-EVALUATION
    KOHLER, TR
    STRATTON, JR
    KIRKMAN, TR
    JOHANSEN, KH
    ZIERLER, BK
    CLOWES, AW
    SURGERY, 1992, 112 (05) : 901 - 907
  • [13] HEALING OF HIGH-POROSITY POLYTETRAFLUOROETHYLENE ARTERIAL GRAFTS IS INFLUENCED BY THE NATURE OF THE SURROUNDING TISSUE
    STERPETTI, AV
    HUNTER, WJ
    SCHULTZ, RD
    FARINA, C
    SURGERY, 1992, 111 (06) : 677 - 682
  • [14] MODIFIED POLYTETRAFLUOROETHYLENE - IN-111 LABELED PLATELET DEPOSITION ON CARBON-LINED AND HIGH-POROSITY POLYTETRAFLUOROETHYLENE GRAFTS
    TSUCHIDA, H
    CAMERON, BL
    MARCUS, CS
    WILSON, SE
    JOURNAL OF VASCULAR SURGERY, 1992, 16 (04) : 643 - 650
  • [15] Polytetrafluoroethylene expanded prosthesis as replacement of the inferior vena cava in renal cell carcinoma with caval thrombus
    Benkirane, Ahmed
    Khodari, Muhieddine
    Yakoubi, Rachid
    Lambert, Marc
    Koussa, Mohamad
    Ghoneim, Tarek
    Haulon, Stephan
    Villers, Arnauld
    Lemaitre, Laurent
    Zini, Laurent
    INTERNATIONAL JOURNAL OF UROLOGY, 2014, 21 (05) : 448 - 452
  • [16] Effects of fibronectin bonding on healing of high porosity expanded polytetrafluoroethylene grafts in pigs
    Nishibe, T
    O'Donnel, S
    Pikoulis, E
    Rich, N
    Okuda, Y
    Kumada, T
    Kudo, F
    Tanabe, T
    Yasuda, K
    JOURNAL OF CARDIOVASCULAR SURGERY, 2001, 42 (05): : 667 - 673
  • [17] PSEUDO-ENDOTHELIUM FORMATION IN EXPANDED POLYTETRAFLUOROETHYLENE GRAFTS IMPLANTED IN THE INFERIOR VENA-CAVA OF NORMAL AND DEFIBRINOGENATED DOGS
    ISHIMARU, S
    BERGLIN, E
    HANSSON, HA
    TEGERNILSSON, AC
    WILLIAMOLSSON, G
    ARTIFICIAL ORGANS, 1981, 5 (04) : 379 - 387
  • [18] HIGH-POROSITY PTFE IMPROVES ENDOTHELIALIZATION OF ARTERIAL GRAFTS WITHOUT INCREASING EARLY THROMBOGENICITY
    CAMERON, BL
    TSUCHIDA, H
    CONNALL, TP
    NAGAE, T
    FURUKAWA, K
    WILSON, SE
    JOURNAL OF CARDIOVASCULAR SURGERY, 1993, 34 (04): : 281 - 285
  • [19] REPLACEMENT OF THE SUPERIOR VENA-CAVA WITH POLYTETRAFLUOROETHYLENE GRAFTS COMBINED WITH RESECTION OF MEDIASTINAL-PULMONARY MALIGNANT-TUMORS - REPORT OF 13 CASES
    DARTEVELLE, P
    CHAPELIER, A
    NAVAJAS, M
    LEVASSEUR, P
    ROJAS, A
    KHALIFE, J
    LAFONTAINE, E
    MERLIER, M
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1987, 94 (03): : 361 - 366
  • [20] TOTAL REPLACEMENT OF THE SUPRARENAL INFERIOR VENA-CAVA WITH AN EXPANDED POLYTETRAFLUOROETHYLENE TUBE GRAFT IN 2 PATIENTS WITH TUMOR THROMBI FROM RENAL-CELL CARCINOMA
    OKADA, Y
    KUMADA, K
    HABUCHI, T
    OHNISHI, H
    NISHIMURA, K
    YOSHIDA, O
    JOURNAL OF UROLOGY, 1989, 141 (01): : 111 - 114