A competitive immunoassay for electrochemical impedimetric determination of chlorpyrifos using a nanogold-modified glassy carbon electrode based on enzymatic biocatalytic precipitation

被引:0
|
作者
Li Hou
Xuanhan Zhang
Man Kong
Gaoyan Jiang
Ying Sun
Weiming Mo
Tianran Lin
Fanggui Ye
Shulin Zhao
机构
[1] College of Chemistry and Pharmaceutical Science of Guangxi Normal University,State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources
来源
Microchimica Acta | 2020年 / 187卷
关键词
Electrochemical determination; Signal amplification; Organophosphorus pesticides; Artificially spiked vegetable; Horseradish peroxidase; Insoluble precipitation;
D O I
暂无
中图分类号
学科分类号
摘要
A direct competitive impedimetric immunoassay for chlorpyrifos (CPF) was developed that is based on the specific affinity of immunoassay and the enzymatic biocatalytic precipitation amplification strategy. The CPF antibody (anti-CPF) was anchored onto an electro-deposited nanogold modified glassy carbon electrode surface by adsorption of the Au-NH2 bond and Au-SH bond. This improved the electrode reactivity and the loading amount of anti-CPF. Abundant horseradish peroxidase (HRP) and bovine serum albumin-CPF (BSA-CPF) were anchored onto spherical gold nanoparticles (AuNPs, 16 ± 2 nm) to form HRP-AuNP-BSA-CPF (analyte competitor). CPF determination was achieved when the competitive immunoassay occurred between CPF and analyte competitor with anti-CPF. In the presence of H2O2 and 4-chloro-1-naphthol, an enzyme-mediated biocatalytic precipitation process was triggered and produced an insoluble 4-chloro-1(4H)-naphthalenone. This insoluble substance increased the Faradaic impedance of the base electrode. The impedimetric signal was determined at the formal potential of 220 mV and alternating voltage of 10 mV. This signal decreased with increasing concentration of CPF over a linear range of 1.0 × 10−3 ng mL−1~10 ng mL−1 with a detection limit of 0.070 pg mL−1. The immunoassay has been tested for determination of chlorpyrifos in complex matrices such as artificially spiked vegetables with recoveries in the range 85 to 110%. The relative standard deviations were less than 7.5%.
引用
收藏
相关论文
共 50 条
  • [31] Non-enzymatic determination of purine nucleotides using a carbon dot modified glassy carbon electrode
    Karthikeyan, R.
    Nelson, D. James
    John, S. Abraham
    ANALYTICAL METHODS, 2019, 11 (30) : 3866 - 3873
  • [32] Electrochemical determination of caffeine in beverage using graphene oxide modified glassy carbon electrode
    Murugan, E.
    Poongan, A.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2021, 28 (05) : 528 - 536
  • [33] Sensitive Electrochemical Determination of Oxcarbazepine using Polymer Film Modified Glassy Carbon Electrode
    Apaydin, Esra Rukiye
    Saglikoglu, Gulsen
    Yilmaz, Selehattin
    Yildiz, Mustafa
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1904 - 1915
  • [34] Electrochemical determination of ascorbic acid using Cu sulfide modified glassy carbon electrode
    Pei L.Z.
    Lin N.
    Wei T.
    Liu H.D.
    Cai Z.Y.
    Surface Engineering and Applied Electrochemistry, 2016, 52 (6) : 565 - 571
  • [35] Electrochemical Determination of Carboplatin in Serum Using a DNA-Modified Glassy Carbon Electrode
    Brett, A. M. O.
    Serrano, S. H. P.
    Macedo, T. A.
    Raimundo, D.
    Electroanalysis, 8 (11):
  • [36] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306
  • [37] Electrochemical Determination of Levofloxacin Using Poly(Pyrogallol Red) Modified Glassy Carbon Electrode
    Kocak, Cagri Ceylan
    Aslisen, Burak
    Karabiberoglu, Sukriye
    Ozdokur, Kemal Volkan
    Aslan, Avni
    Kocak, Suleyman
    CHEMISTRYSELECT, 2022, 7 (41):
  • [38] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Vimal Sharma
    David Hynek
    Libuse Trnkova
    Dusan Hemzal
    Marian Marik
    Rene Kizek
    Jaromir Hubalek
    Microchimica Acta, 2016, 183 : 1299 - 1306
  • [39] Fabrication of an Electrochemical Sensor for Determination of Epinephrine Using a Glassy Carbon Electrode Modified with Catechol
    Mazloum-Ardakani, Mohammad
    Alvansaz-Yazdi, Farnaz
    Hosseini-Dokht, Farzaneh
    Khoshroo, Alireza
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2023, 10 (04): : 387 - 394
  • [40] Electrochemical determination of carboplatin in serum using a DNA-modified glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Macedo, TA
    Raimundo, D
    Marques, MH
    LaScalea, MA
    ELECTROANALYSIS, 1996, 8 (11) : 992 - 995