An Improved Technique for Prebored Pressuremeter Tests

被引:0
|
作者
Zubair Masoud
Ammad Hassan Khan
机构
[1] SOILCON Geotechnical Engineering Laboratories,Dept. of Transportation Engineering & Management
[2] University of Engineering and Technology,undefined
来源
关键词
prebored pressuremeter; borehole; cavity pressure; strain; mechanical drill system; elastic modulus;
D O I
暂无
中图分类号
学科分类号
摘要
The prebored pressuremeter (PBP) test results depend on the quality of borehole, including its diameter, verticality, effectiveness of cleaning, and degree of wall disturbance. The true elastic modulus cannot be reasonably determined using the cavity pressure-strain curves measured in a borehole of poor quality. In this research, a stainless-steel casing (SSC) was devised to improve the quality of borehole. SSC of 1 to 4 m length was conjugated with a mechanical drilling system (MDS). At a test site, an auger and the MDS with or without the SSC were attempted to drill boreholes for the PBP tests. Among the three techniques, the MDS with SSC produced the reliable values of the initial elastic modulus at a low strain range (0.003% to 0.089%).
引用
收藏
页码:2839 / 2846
页数:7
相关论文
共 50 条
  • [41] RATE EFFECTS IN PRESSUREMETER TESTS IN CLAYS.
    Anderson, William F.
    Pyrah, Ian C.
    Ali, Faisal Haji
    Journal of geotechnical engineering, 1987, 113 (11): : 1344 - 1358
  • [42] Laboratory pressuremeter tests on reconstituted sill samples
    Belkacemi, S
    Kauschinger, JL
    GEOTECHNICAL SITE CHARACTERIZATION, VOLS 1 AND 2, 1998, : 741 - 745
  • [43] STRAIN-DEPENDENT MODULI AND PRESSUREMETER TESTS
    WOOD, DM
    GEOTECHNIQUE, 1990, 40 (03): : 509 - 512
  • [44] Analysis of cone pressuremeter tests in sands - Closure
    Yu, HS
    Schnaid, F
    Collins, IF
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1997, 123 (09) : 886 - 887
  • [45] Identification of soil parameters from pressuremeter tests
    Yin, Z. Y.
    Hicher, P. Y.
    Huang, H. W.
    NUMERICAL METHODS IN GEOTECHNICAL ENGINEERING, 2006, : 147 - 152
  • [46] Analysis of cone pressuremeter tests in sands - Discussion
    Howie, JA
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1997, 123 (09) : 884 - 886
  • [47] Unsaturated constitutive surfaces from pressuremeter tests
    Schnaid, F
    de Oliveira, LAK
    Gehling, WYY
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2004, 130 (02) : 174 - 185
  • [48] THE EFFECTS OF PRESSUREMETER GEOMETRY ON THE RESULTS OF TESTS IN CLAY
    HOULSBY, GT
    CARTER, JP
    GEOTECHNIQUE, 1993, 43 (04): : 567 - 576
  • [49] IMPROVED TECHNIQUE FOR NASAL INHALATION CHALLENGE TESTS
    MCLEAN, JA
    CIARKOWSKI, AA
    SOLOMON, WR
    MATHEWS, KP
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1976, 57 (02) : 153 - 163
  • [50] IMPROVED TECHNIQUE OF AGGLUTINATION MEASUREMENTS IN IMMUNOLOGICAL TESTS
    YASHCHENKO, LV
    YAROSH, AM
    GAKH, LM
    CHISTYAKOV, IV
    LABORATORNOE DELO, 1985, (07): : 415 - 417