Differential pulse adsorptive stripping voltammetric determination of simeton in its formulations and vegetables

被引:0
|
作者
N. Y. Sreedhar
M. Sankara Nayak
K. N. Shashi Kumar
K. Srinivasa Prasad
P. Reddy Prasad
机构
[1] S.V. University,Department of Chemistry
来源
关键词
DP-AdSV; Simeton; Grains; Formulations;
D O I
暂无
中图分类号
学科分类号
摘要
A sensitive adsorptive stripping voltammetric method for the determination of simeton with universal buffer solution has been described. The method was based on the adsorption accumulation of simeton at a hanging mercury drop electrode. The overall reduction process is under controlled diffusion. The adsorptive peak was observed at −0.8 V vs SCE in acidic solution 2 < pH < 6. The peak response was characterized with respect to pH, accumulation potential, time, and scan rate. The calibration plot was found to be linear from 1.13 × 10 − 5 to 3.5 × 10 − 8 M with a limit of detection of 2.0 × 10 − 8 M. Finally, the method has been applied for the determination of simeton in its formulations and vegetable samples.
引用
收藏
页码:59 / 63
页数:4
相关论文