Electrochemical Behavior and Determination of Clozapine on a Glassy Carbon Electrode Modified by Electrochemical Oxidation

被引:0
|
作者
Khalil Farhadc
Ahmad Karimpour
机构
[1] Urmia University,Department of Chemistry, Faculty of Science
来源
Analytical Sciences | 2007年 / 23卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The adsorptive and electrochemical behaviors of clozapine (CLZ) were investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to 1.0 V vs. Ag/AgCl reference electrode. Based on the obtained electrochemical results, an electrochemical-chemical (EC) mechanism was proposed to explain the electrochemical oxidation of CLZ. The resulting electrochemically pretreated glassy carbon electrode (EPGCE) showed good activity to improve the electrochemical response of the drug. CLZ was accumulated in a phosphate buffer (pH 6) at a certain time, and then determined by differential pulse voltammetry. The anodic and cathodic peak currents showed a linear function in the concentration ranges of 0.1–1, 1–10 and 10–100 μM with various accumulation times. The proposed method was successfully used for the determination of CLZ in pharmaceutical preparations. The preconcentration medium-exchange approach was utilized for the selective determination of the drug in spiked urine samples with satisfactory results. The recovery levels of the method reached 96% (RSD, 1.8%) and 90% (RSD, 2.8%) for urine and plasma samples, respectively.
引用
收藏
页码:479 / 483
页数:4
相关论文
共 50 条
  • [31] Facile electrochemical determination of tetrabromobisphenol A based on modified glassy carbon electrode
    Zhao, Qiang
    Zhang, Ke
    Yu, Guangxia
    Wu, Weixiang
    Wei, Xiaoyun
    Lu, Qing
    TALANTA, 2016, 151 : 209 - 216
  • [32] CuO nanoflowers modified glassy carbon electrode for the electrochemical determination of methionine
    Ebrahimi, Maryam
    Beitollahi, Hadi
    EURASIAN CHEMICAL COMMUNICATIONS, 2021, 3 (01): : 19 - 25
  • [33] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Tufa, Lemma Teshome
    Siraj, Khalid
    Soreta, Tesfaye Refera
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (01) : 59 - 66
  • [34] Polymer modified glassy carbon electrode for the electrochemical determination of caffeine in coffee
    Amare, Meareg
    Admassie, Shimelis
    TALANTA, 2012, 93 : 122 - 128
  • [35] Electrochemical Determination of Malathion on an Acetylcholinesterase-Modified Glassy Carbon Electrode
    Shamgsumova, Rezeda V.
    Shurpik, Dmitry N.
    Evtugyn, Vladimir G.
    Stoikov, Ivan I.
    Evtugyn, Gennady A.
    ANALYTICAL LETTERS, 2018, 51 (12) : 1911 - 1926
  • [36] Determination of noradrenaline at glassy carbon electrode modified with bilayer lipid membrane and its electrochemical behavior
    Jin, SZ
    Lu, LZ
    Shen, HX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (10) : 1314 - 1316
  • [37] Electrochemical behavior of Co(II) polymer-modified glassy carbon electrode for the determination of dopamine
    Vladislavic, Nives
    Roncevic, Ivana Skugor
    Buzuk, Marijo
    Dugec, Josipa
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024, 28 (11) : 4311 - 4323
  • [38] Acylpyrazolone Modified Glassy Carbon Electrode Effect on the Electrochemical Behavior of Tyrosine
    Zhang Dan
    Li Jin-zhou
    ANALYTICAL LETTERS, 2008, 41 (15) : 2832 - 2843
  • [39] ELECTROCHEMICAL-BEHAVIOR OF A PHOSPHOLIPID MODIFIED GLASSY-CARBON ELECTRODE
    CHASTEL, O
    LOPEZ, V
    KAUFFMANN, JM
    PATRIARCHE, GJ
    ANALUSIS, 1989, 17 (10) : 581 - 586
  • [40] Determination of nitrofurantoin and its electrochemical behavior at cobalt ion implantation modified glassy carbon electrode
    Tan, XC
    Qiu, JD
    Li, Y
    Zou, XY
    Cai, PX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 930 - 934