Fluorometric nanoprobes for simultaneous aptamer-based detection of carcinoembryonic antigen and prostate specific antigen

被引:0
|
作者
Yali Sun
Jianfeng Fan
Linyan Cui
Wei Ke
Fangjie Zheng
Yuan Zhao
机构
[1] Jiangnan University,Key Lab of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering
[2] Wuxi Children’s Hospital,undefined
来源
Microchimica Acta | 2019年 / 186卷
关键词
Fluorescence; MoS; nanosheets; Dual detection; CEA; PSA;
D O I
暂无
中图分类号
学科分类号
摘要
A “turn-on” fluorometric assay based on the combined effects of fluorescence resonance energy transfer (FRET) and internal filter effect (IFE) is described for the rapid and ultrasensitive detection of both carcinoembryonic antigen (CEA) and prostate specific antigen (PSA). Their unique porous structures and high specific surface enable mesoporous silica nanoparticles (MSNs) to load a large number of CdTe quantum dots (QDs). These amplify the fluorescence signal and provide a platform to fabricate more distinctly fluorescent MSNs (QD-MSNs). Two kinds of QD-MSNs with the maximum emission wavelengths at 590 nm (orange) and 731 nm (dark red) were fabricated and served as two types of fluorescent probes for the dual detection. Two aptamers were covalently connected to fluorescent MSNs as the recognition unit to warrant the selectivity of assay. The fluorescence of QD-MSNs can be quenched by molybdenum disulfide nanosheets (MoS2) due to FRET mechanism, IFE also contributed to the the reduction of fluorescence intensity. The fluorescence of QD-MSNs was further recovered in the presence of CEA and PSA attributing to the excellent specificity of aptamers. A “turn-on” fluorescent two-channel nanoprobe is introduced for simultaneous quantification of CEA and PSA. The respective limits of detection (at S/N = 3) are 0.7 fg•mL−1 for CEA and 0.9 fg•mL−1 for PSA.
引用
收藏
相关论文
共 50 条
  • [41] Aptamer-MIP hybrid receptor for highly sensitive electrochemical detection of prostate specific antigen
    Jolly, Pawan
    Tamboli, Vibha
    Harniman, Robert L.
    Estrela, Pedro
    Allender, Chris J.
    Bowen, Jenna L.
    BIOSENSORS & BIOELECTRONICS, 2016, 75 : 188 - 195
  • [42] Adenocarcinoma of the prostate immunostained for carbohydrate antigen 125 and carcinoembryonic antigen
    Kiyokawa, H
    Koyama, M
    Kato, H
    BJU INTERNATIONAL, 2003, 91 (03) : 298 - 299
  • [43] Simplified aptamer-based colorimetric method using unmodified gold nanoparticles for the detection of carcinoma embryonic antigen
    Luo, Cheng
    Wen, Wei
    Lin, Fenge
    Zhang, Xiuhua
    Gu, Haoshuang
    Wang, Shengfu
    RSC ADVANCES, 2015, 5 (15) : 10994 - 10999
  • [44] A Multicenter Study of [-2]Pro-Prostate Specific Antigen Combined With Prostate Specific Antigen and Free Prostate Specific Antigen for Prostate Cancer Detection in the 2.0 to 10.0 ng/ml Prostate Specific Antigen Range
    Catalona, William J.
    Partin, Alan W.
    Sanda, Martin G.
    Wei, John T.
    Klee, George G.
    Bangma, Chris H.
    Slawin, Kevin M.
    Marks, Leonard S.
    Loeb, Stacy
    Broyles, Dennis L.
    Shin, Sanghyuk S.
    Cruz, Amabelle B.
    Chan, Daniel W.
    Sokoll, Lori J.
    Roberts, William L.
    van Schaik, Ron H. N.
    Mizrahi, Isaac A.
    JOURNAL OF UROLOGY, 2011, 185 (05): : 1650 - 1655
  • [45] CARCINOEMBRYONIC ANTIGEN IN DIAGNOSIS OF PROSTATE CARCINOMA
    NEUFELD, L
    DUBIN, A
    GUINAN, P
    NABONG, R
    ABLIN, RJ
    BUSH, IM
    ONCOLOGY, 1974, 29 (05) : 376 - 381
  • [47] Flow injection immunoassay for carcinoembryonic antigen combined with time-resolved fluorometric detection
    Yan, F
    Zhou, JN
    Lin, JH
    Ju, HX
    Hu, XY
    JOURNAL OF IMMUNOLOGICAL METHODS, 2005, 305 (02) : 120 - 127
  • [48] Prostate cancer detection at low prostate specific antigen
    Schröder, FH
    van der Cruijsen-Koeter, I
    de Koning, HJ
    Vis, AN
    Hoedemaeker, RF
    Kranse, R
    JOURNAL OF UROLOGY, 2000, 163 (03): : 806 - 811
  • [49] Detection of prostate cancer by prostate-specific antigen
    Egawa, S
    BIOMEDICINE & PHARMACOTHERAPY, 2001, 55 (03) : 130 - 134
  • [50] Sensitive immunosensing of the carcinoembryonic antigen utilizing aptamer-based in-situ formation of a redox-active heteropolyacid and rolling circle amplification
    Wentao Jiang
    Lei Liu
    Li Zhang
    Qingjun Guo
    Yujun Cui
    Minghui Yang
    Microchimica Acta, 2017, 184 : 4757 - 4763