Simultaneous detection of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes using oscillatory-flow multiplex PCR

被引:0
|
作者
Haiying Wang
Chunsun Zhang
Da Xing
机构
[1] South China Normal University,MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics
来源
Microchimica Acta | 2011年 / 173卷
关键词
Microfluidics; Oscillatory-flow; Multiplex polymerase chain reaction; Foodborne bacterial pathogens;
D O I
暂无
中图分类号
学科分类号
摘要
An oscillatory-flow multiplex PCR method in a capillary microfluidic channel has been developed for the simultaneous determination of pre-purified DNA of multiple foodborne bacterial pathogens. The PCR solution passes three temperature zones in an oscillatory manner. The thermal stability and sample evaporation of the microfluidic device were investigated. Under controlled conditions, a highly efficient multiplex PCR was accomplished as demonstrated for the simultaneous amplifications of 278 bp, 168 bp, and 106 bp DNA fragments within 35 min after 35 cycles for simultaneous detection of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes. This is much shorter than that of a conventional PCR machine. The detection limits of bacterial genome DNA for the three species are about 399, 314, and 626 copies per μL, respectively. This is comparable to those obtained with the conventional multiplex PCR. Consequently, the oscillatory-flow multiplex PCR technology holds good potential for rapid amplification and detection of nucleic acids of microbial foodborne pathogens.
引用
收藏
页码:503 / 512
页数:9
相关论文
共 50 条
  • [21] Mixed culture enrichment of Escherichia coli O157:H7, Listeria monocytogenes, Salmonella enterica, and Yersinia enterocolitica
    Gehring, Andrew G.
    Albin, David M.
    Bhunia, Arun K.
    Kim, Hyochin
    Reed, Sue A.
    Tu, Shu-I
    FOOD CONTROL, 2012, 26 (02) : 269 - 273
  • [22] Multiplex PCR for detection of Escherichia coli O157:H7 in foods
    Vidova, Barbora
    Tothova, Eva
    Blahut, L'uboslav
    Horvathova, Viera
    Godany, Andrej
    BIOLOGIA, 2011, 66 (03) : 401 - 405
  • [23] Multiplex PCR for detection of Escherichia coli O157:H7 in foods
    Barbora Vidová
    Eva Tóthová
    Ľuboslav Blahut
    Viera Horváthová
    Andrej Godány
    Biologia, 2011, 66 : 401 - 405
  • [24] DETECTION OF ESCHERICHIA-COLI O157/H7 BY MULTIPLEX PCR
    FRATAMICO, PM
    SACKITEY, SK
    WIEDMANN, M
    DENG, MY
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (08) : 2188 - 2191
  • [25] Simultaneous detection of Escherichia coli O175:H7, Salmonella spp., and Listeria monocytogenes by multiplex PCR
    Germini, Andrea
    Masola, Annalisa
    Carnevali, Paola
    Marchelli, Rosangela
    FOOD CONTROL, 2009, 20 (08) : 733 - 738
  • [26] Target-Enriched Multiplex PCR (TEM-PCR) Assay for Simultaneous Detection of Salmonella spp., Listeria Monocytogenes and Escherichia Coli O157:H7 in Food
    Liu, Zhong-Mei
    Xu, Yi-Gang
    Luo, Jia
    Qu, Min
    Mo, Chun-Sheng
    Li, Su-Long
    JOURNAL OF FOOD SAFETY, 2016, 36 (02) : 180 - 185
  • [27] Survival of Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella in juice concentrates
    Oyarzábal, OA
    Nogueira, MCL
    Gombas, DE
    JOURNAL OF FOOD PROTECTION, 2003, 66 (09) : 1595 - 1598
  • [28] A duplex qPCR for the simultaneous detection of Escherichia coli O157:H7 and Listeria monocytogenes using LNA probes
    Nitecki, S. S.
    Teape, N.
    Carney, B. F.
    Slater, J. W.
    Brueck, W. M.
    LETTERS IN APPLIED MICROBIOLOGY, 2015, 61 (01) : 20 - 27
  • [29] Detection of Escherichia coli O157:H7 in soil and water using multiplex PCR
    Campbell, GR
    Prosser, J
    Glover, A
    Killham, K
    JOURNAL OF APPLIED MICROBIOLOGY, 2001, 91 (06) : 1004 - 1010
  • [30] Sanitizing effectiveness of commercial "active water" technologies on Escherichia coli O157:H7, Salmonella enterica and Listeria monocytogenes
    Yang, Hongshun
    Feirtag, Joellen
    Diez-Gonzalez, Francisco
    FOOD CONTROL, 2013, 33 (01) : 232 - 238