Effect of compressive load on oblique pull-out capacity of model piles in sand

被引:17
|
作者
Krishna B. [1 ]
Patra N.R. [1 ]
机构
[1] Department of Civil Engineering, Indian Institute of Technology
来源
关键词
Compression; Laboratory test; Models; Oblique loads; Piles; Sand;
D O I
10.1007/s10706-005-1307-7
中图分类号
学科分类号
摘要
Model tests on steel piles embedded in sand were carried out in the laboratory to study the effects of compressive load (i.e. 0, 25, 50, 75, and 100% of their ultimate capacity in compression) on oblique pull-out capacity of piles. The model piles were of 20 mm × 20 mm cross section, which had an embedded length of 400 and 600 mm. The pull was applied at an inclination of 0°, 30°, 60° and 90° with vertical axis of the piles. The experimental results indicate that the net oblique pull-out capacity of piles decreases with increase in % of compressive load and the decrease depends on the magnitude of the compressive load. Semi-empirical methods, based on experimental results, have been suggested to determine the oblique pull-out resistance of piles subjected to static compressive loads. A comparison of predicted values of the ultimate oblique resistance by proposed methods of analysis with experimental values, and also with those reported by others, showed reasonably good agreement. © Springer 2006.
引用
收藏
页码:593 / 614
页数:21
相关论文
共 50 条
  • [31] Numerical investigation of pull-out capacity and failure mechanism of suction anchors with mooring line in sand
    Zhang, Min-Hao
    Yin, Zhen-Yu
    Fu, Yong
    OCEAN ENGINEERING, 2023, 280
  • [32] Physical Model Test for the Pull-Out Behavior of a Load Distributive Compression Anchor
    Shin, Gyu-Beom
    Jo, Bum-Hee
    Han, Joung Woo
    Chung, Choong-Ki
    GEO-CONGRESS 2022: GEOPHYSICAL AND EARTHQUAKE ENGINEERING AND SOIL DYNAMICS, 2022, 334 : 149 - 158
  • [33] Pull-out capacity of adhesive anchors: An analytical solution
    Upadhyaya, Priyank
    Kumar, S.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2015, 60 : 54 - 62
  • [34] Electro-osmosis for Reducing Pull-out Resistance of Sheet Piles
    Vrettos, Christos
    GEOTECHNIK, 2011, 34 (01) : 78 - 78
  • [35] TENSILE AND COMPRESSIVE SHAFT CAPACITY OF PILES IN SAND - DISCUSSION
    ZHANG, LY
    SARGAND, SM
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1995, 121 (04): : 403 - 404
  • [36] Axial compressive capacity of short tapered piles in sand
    Jin-Cheng, Su
    UPB Scientific Bulletin, Series D: Mechanical Engineering, 2019, 81 (02): : 115 - 124
  • [37] Experimental study on pull-out response of geogrid embedded in sand
    Kayadelen, Cafer
    Onal, Taha Okkes
    Altay, Gokhan
    MEASUREMENT, 2018, 117 : 390 - 396
  • [38] Disturbed state model for sand-geosynthetic interfaces and application to pull-out tests
    Pal, S
    Wathugala, GW
    INTERNATIONAL JOURNAL FOR NUMERICAL AND ANALYTICAL METHODS IN GEOMECHANICS, 1999, 23 (15) : 1873 - 1892
  • [39] TENSILE AND COMPRESSIVE SHAFT CAPACITY OF PILES IN SAND - CLOSURE
    DENICOLA, A
    RANDOLPH, MF
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1995, 121 (04): : 404 - 405
  • [40] Effect of bar shape on the pull-out capacity of fully-grouted rockbolts
    Kilic, A
    Yasar, E
    Atis, CD
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2003, 18 (01) : 1 - 6