An aptasensor for voltammetric and impedimetric determination of cocaine based on a glassy carbon electrode modified with platinum nanoparticles and using rutin as a redox probe

被引:0
|
作者
Mahmoud Roushani
Faezeh Shahdost-fard
机构
[1] Ilam University,Department of Chemistry
来源
Microchimica Acta | 2016年 / 183卷
关键词
Aptasensor; Rutin; Platinum nanoparticles; Differential pulse voltammetry; Electrochemical impedance spectroscopy; Scanning electron microscopy;
D O I
暂无
中图分类号
学科分类号
摘要
We describe a method for the determination of cocaine that is based on a glassy carbon electrode modified with a nanocomposite consisting of multiwalled carbon nanotubes, an ionic liquid, and chitosan. The electrode was made cocaine-responsive by immobilizing a cocaine-specific aptamer and platinum nanoparticles (PtNPs) on the modified electrode. The use of PtNPs resulted in the acceleration of the electron transfer kinetics of the reduction of the redox probe rutin and enhances sensitivity. The sensor, best operated at a working voltage of 260 mV vs. Ag/AgCl, has a linear response to cocaine in the 1 nM to 11 μM concentration range, and the detection limit is 100 pM (at an S/N ratio of 3). We think this strategy to represent a promising platform for the sensitive and selective determination of cocaine. The sensor is adequately stable and was successfully applied to the determination of cocaine in spiked serum.
引用
收藏
页码:185 / 193
页数:8
相关论文
共 50 条
  • [41] Impedimetric Salmonella aptasensor using a glassy carbon electrode modified with an electrodeposited composite consisting of reduced graphene oxide and carbon nanotubes
    Fei Jia
    Nuo Duan
    Shijia Wu
    Ruitong Dai
    Zhouping Wang
    Xingmin Li
    Microchimica Acta, 2016, 183 : 337 - 344
  • [42] Atrazine Voltammetric Determination in the Pesticide Industries Wastewater by Gold Nanoparticles at a Modified Glassy Carbon Electrode
    Memon, Safia Sanam
    Waris, Muhammad
    Sidhu, Ahmed Raza
    Zaqa, Marriam
    PORTUGALIAE ELECTROCHIMICA ACTA, 2022, 40 (05) : 363 - 372
  • [43] Voltammetric Determination of Sulfonamides with a Modified Glassy Carbon Electrode Using Carboxyl Multiwalled Carbon Nanotubes
    He, Bao-Shan
    Chen, Wen-Bo
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (12) : 2216 - 2225
  • [44] Determination of Fenitrothion in Water Using a Voltammetric Sensor Based on a Polymer-Modified Glassy Carbon Electrode
    Amare, Meareg
    Abicho, Samuel
    Admassie, Shimelis
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (02) : 580 - 585
  • [46] Voltammetric Determination of Chili Peppers Pungency using Phospholipid Modified Glassy Carbon Electrode
    Skopalova, Jana
    Rajcova, Andrea
    Vokounova, Sarka
    Navratil, Tomas
    PROCEEDINGS OF INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXIX, 2019, : 188 - 192
  • [47] Direct determination of oxalic acid by a bare platinum electrode contrasting a platinum nanoparticles-modified glassy carbon electrode
    Ma, Le
    Zeng, Qiang
    Zhang, Min
    Wang, Lishi
    Cheng, Faliang
    JOURNAL OF EXPERIMENTAL NANOSCIENCE, 2016, 11 (16) : 1242 - 1252
  • [48] Voltammetric determination of mitomycin C using a chemically-modified glassy carbon electrode
    Qu, WY
    Wang, H
    Wu, HB
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2005, 70 (02) : 178 - 187
  • [49] Sensitive voltammetric determination of neohesperidin dihydrochalcone based on SWNTs modified glassy carbon electrode
    Yang, Lingxi
    Wang, Lu
    Li, Kunjing
    Ye, Baoxian
    ANALYTICAL METHODS, 2014, 6 (23) : 9410 - 9418
  • [50] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    Baranowska, I.
    Bijak, K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (10) : 891 - 895