Identification of Marchfeld asparagus using Sr isotope ratio measurements by MC-ICP-MS

被引:0
|
作者
S. Swoboda
M. Brunner
S. F. Boulyga
P. Galler
M. Horacek
T. Prohaska
机构
[1] University of Natural Resources and Applied Life Sciences,Department of Chemistry
[2] Austrian Research Centers GmbH,VIRIS Project
来源
Analytical and Bioanalytical Chemistry | 2008年 / 390卷
关键词
Food authentication; Strontium isotope ratio measurements; Multicollector inductively coupled plasma mass spectrometry delimeter Asparagus; Soil;
D O I
暂无
中图分类号
学科分类号
摘要
This work focuses on testing and application of Sr isotope signatures for the fast and reliable authentication and traceability of Asparagus officinalis originating from Marchfeld, Austria, using multicollector inductively coupled plasma mass spectrometry after optimised Rb/Sr separation. The major sample pool comprises freeze-dried and microwave-digested asparagus samples from Hungary and Slovakia which are compared with Austrian asparagus originating from the Marchfeld region, which is a protected geographical indication. Additional samples from Peru, the Netherlands and Germany were limited in number and allowed therefore only restricted statistical evaluation. Asparagus samples from Marchfeld were harvested within two subsequent years in order to investigate the annual variation. The results show that the Sr isotope ratio is consistent within these 2 years of investigation. Moreover, the Sr isotope ratio of total Sr in soil was found to be significantly higher than in an NH4NO3 extract, reflecting the mobile (bioavailable) phase. The isotope composition in the latter extract corresponds well to the range found in the asparagus samples in Marchfeld, even though the concentration of Sr in asparagus shows no direct correlation to the concentration of Sr in the mobile phase of the soil. The major question was whether the ‘Marchfelder Spargel’ can be distinguished from samples from the neighbouring countries of Hungary and Slovakia. According to our findings, they can be clearly (100%) singled out from the Hungarian samples and can be distinguished from the Slovakian asparagus samples with a probability of more than 80%.
引用
收藏
页码:487 / 494
页数:7
相关论文
共 50 条
  • [21] Silicon isotope measurements using MC-ICP-MS: Early results from weathering studies
    Land, M
    Andersson, PS
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A440 - A440
  • [22] High-Precision Barium Isotope Measurements of Carbonates by MC-ICP-MS
    Zeng, Zhen
    Li, Xiaohua
    Liu, Yi
    Huang, Fang
    Yu, Hui-Min
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2019, 43 (02) : 291 - 300
  • [23] Gd matrix effects on Eu isotope fractionation using MC-ICP-MS: Optimizing europium isotope ratio measurements in geological rock samples
    Lee, Seung-Gu
    Tanaka, Tsuyoshi
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 469
  • [24] Silicon Isotope Measurement of Giant Diatoms Using MC-ICP-MS
    Choi, Ah Yeong
    Ryu, Jong-Sik
    Hyeong, Kiseong
    Kim, Mun Gi
    Ra, Kongtae
    Jeong, Hyeryeong
    Lim, Hyoun Soo
    JOURNAL OF THE KOREAN EARTH SCIENCE SOCIETY, 2021, 42 (01): : 1 - 10
  • [25] Lithium isotope analysis on the Neoma MS/MS MC-ICP-MS
    Scott, Sean R.
    Turner, Gabrielle L.
    Gartman, Brandy N.
    Anguiano, Sonia Alcantar
    Melby, Kali M.
    Allen, Barbara E.
    Minton, Travis D.
    Risenhuber, Matthew A.
    Hobbs, Kirby P.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (04) : 1098 - 1105
  • [26] A critical review on isotopic fractionation correction methods for accurate isotope amount ratio measurements by MC-ICP-MS
    Yang, Lu
    Tong, Shuoyun
    Zhou, Lian
    Hu, Zhaochu
    Mester, Zoltan
    Meija, Juris
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (11) : 1849 - 1861
  • [27] Stable Cr isotope ratio measurements using a double-spike method and high-resolution MC-ICP-MS
    von Blanckenburg, F
    Schoenberg, R
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A867 - A867
  • [28] Tantalum isotope ratio measurements and isotope abundances determined by MC-ICP-MS using amplifiers equipped with 1010, 1012 and 1013 Ohm resistors
    Pfeifer, M.
    Lloyd, N. S.
    Peters, S. T. M.
    Wombacher, F.
    Elfers, B. -M.
    Schulz, T.
    Munker, C.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 130 - 143
  • [29] New sequential separation procedure for Sr, Nd and Pb isotope ratio measurement in geological material using MC-ICP-MS and TIMS
    Makishima, Akio
    Nath, B. Nagender
    Nakamura, Eizo
    GEOCHEMICAL JOURNAL, 2008, 42 (03) : 237 - 246
  • [30] Precise isotope ratio measurements by MC-ICP-MS and application of the isotope dilution technique for the determination of germanium in the Gallium Neutrino Observatory
    Wallenius, M.
    Mayer, K.
    Millet, S.
    Nicholl, A.
    Henrich, E.
    Balata, M.
    Nisi, S.
    Luetzenkirchen, K.
    RADIOCHIMICA ACTA, 2008, 96 (08) : 449 - 453