Ultra-low-dose CT for attenuation correction: dose savings and effect on PET quantification for protocols with and without tin filter

被引:3
|
作者
Bebbington N.A. [1 ]
Christensen K.B. [2 ]
Østergård L.L. [2 ]
Holdgaard P.C. [2 ]
机构
[1] Siemens Healthcare A/S, Borupvang 9, Ballerup
[2] Department of Nuclear Medicine, Lillebaelt Hospital - University Hospital of Southern Denmark, Beriderbakken 4, Vejle
关键词
Attenuation correction; CT; Dose; PET; Quantification; Tin filter; Ultra-low;
D O I
10.1186/s40658-023-00585-0
中图分类号
学科分类号
摘要
Background: Ultra-low-dose (ULD) computed tomography (CT) scans should be used when CT is performed only for attenuation correction (AC) of positron emission tomography (PET) data. A tin filter can be used in addition to the standard aluminium bowtie filter to reduce CT radiation dose to patients. The aim was to determine how low CT doses can be, when utilised for PET AC, with and without the tin filter, whilst providing adequate PET quantification. Methods: A water-filled NEMA image quality phantom was imaged in three configurations with 18F-FDG: (1) water only (0HU); (2) with cylindrical insert containing homogenous mix of sand, flour and water (SFW, approximately 475HU); (3) with cylindrical insert containing sand (approximately 1100HU). Each underwent one-bed-position (26.3 cm) PET-CT comprising 1 PET and 13 CT acquisitions. CT acquisitions with tube current modulation were performed at 120 kV/50 mAs-ref (reference standard), 100 kV/7 mAs-ref (standard ULDCT for PET AC protocol), Sn140kV (mAs range 7–50-ref) and Sn100kV (mAs range 12–400-ref). PET data were reconstructed with μ-maps provided by each CT dataset, and PET activity concentration measured in each reconstruction. Differences in CT dose length product (DLP) and PET quantification were determined relative to the reference standard. Results: At each tube voltage, changes in PET quantification were greater with increasing density and reducing mAs. Compared with the reference standard, differences in PET quantification for the standard ULDCT protocol for the three phantoms were ≤ 1.7%, with the water phantom providing a DLP of 7mGy.cm. With tin filter at Sn100kV, differences in PET quantification were negligible (≤ 1.2%) for all phantoms down to 50mAs-ref, proving a DLP of 2.8mGy.cm, at 60% dose reduction compared with standard ULDCT protocol. Below 50mAs-ref, differences in PET quantification were > 2% for at least one phantom (2.3% at 25mAs-ref in SFW; 6.4% at 12mAs-ref in sand). At Sn140kV/7mAs-ref, quantification differences were ≤ 0.6% in water, giving 3.8mGy.cm DLP, but increased to > 2% at bone-equivalent densities. Conclusions: CT protocols for PET AC can provide ultra-low doses with adequate PET quantification. The tin filter can allow 60–87% lower dose than the standard ULDCT protocol for PET AC, depending on tissue density and accepted change in PET quantification. © 2023, Springer Nature Switzerland AG.
引用
收藏
相关论文
共 50 条
  • [11] Optimization of low dose CT based attenuation correction for brain PET/CT protocols
    Kim, Jung Sun
    Kim, Ho Sung
    Ryu, Jae Kwang
    Jung, Woo Young
    Dong, Kyeong Rae
    Chung, Woon Kwan
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [12] Accuracy of cardiac PET with ultra-low-dose CT/AC
    Hamill, James
    Eisner, Robert
    Streeter, James
    Patterson, Randolph
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [13] Determining the Minimal Required Ultra-Low-Dose CT Dose Level for Reliable Attenuation Correction of 18F-FDG PET/CT: A Phantom Study
    Cheng, David W.
    Ghita, Monica
    Menard, David
    Chen, Ming-Kai
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2022, 50 (02) : 126 - 131
  • [14] How Low Can You Go With Ultra-low-dose Tin Filter CT in PET-CT? Evaluation of Dose and Artifacts in a Whole-body Patient Phantom
    Bebbington, N.
    Christensen, K. B.
    Holdgaard, P. C.
    Ostergard, L. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S228 - S228
  • [15] Effect of the dose reduction applied low dose for PET/CT according to CT attenuation correction method
    Jeong, Seung Woo
    Kim, Hong Gyun
    Gwon, Jae Beom
    Shin, Young Man
    Kim, Yeong Heon
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [16] Effect of the dose reduction applied low dose for PET/CT according to CT attenuation correction method
    Jeong, Seung Woo
    Kim, Hong Gyun
    Gwon, Jae Beom
    Shin, Young Man
    Kim, Yeong Heon
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [17] Feasibility of ultra-low-dose PET scan protocols with LSO-TX-based attenuation correction using a long axial field-of-view PET/CT scanner
    Sari, H.
    Teimoorisichani, M.
    Seifert, R.
    Viscione, M.
    Shi, K.
    Morris, M.
    Siegel, E.
    Saboury, B.
    Pyka, T.
    Rominger, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S757 - S757
  • [18] ULTRA-LOW-DOSE COMPUTED TOMOGRAPHY IN UROLITHIASIS-EFFECT OF AN ADDITIONAL TIN FILTER ON IMAGE QUALITY AND RADIATION DOSE
    Haubold, Johannes
    Zensen, Sebastian
    Erfanian, Youssef
    Guberina, Nika
    Opitz, Marcel
    Sawicki, Lino Morris
    Forsting, Michael
    Umutlu, Lale
    Theysohn, Jens M.
    RADIATION PROTECTION DOSIMETRY, 2021, 197 (3-4) : 146 - 153
  • [19] The implementation of (ultra-low dose) CT protocols in PET/CT
    Wojtylak, Patrick
    Sher, Andrew
    Vercher-Conejero, Jose
    Kohan, Andres
    O'Donnell, James
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [20] Towards computer aided emphysema quantification on ultra-low-dose CT:: Reproducibility of ventrodorsal gravity effect measurement and correction
    Wiemker, Rafael
    Opfer, Roland
    Buelow, Thomas
    Rogalla, Patrik
    Steinberg, Amnon
    Dharaiya, Ekta
    Subramanyan, Krishna
    MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514