Ultra-low-dose CT for attenuation correction: dose savings and effect on PET quantification for protocols with and without tin filter

被引:3
|
作者
Bebbington N.A. [1 ]
Christensen K.B. [2 ]
Østergård L.L. [2 ]
Holdgaard P.C. [2 ]
机构
[1] Siemens Healthcare A/S, Borupvang 9, Ballerup
[2] Department of Nuclear Medicine, Lillebaelt Hospital - University Hospital of Southern Denmark, Beriderbakken 4, Vejle
关键词
Attenuation correction; CT; Dose; PET; Quantification; Tin filter; Ultra-low;
D O I
10.1186/s40658-023-00585-0
中图分类号
学科分类号
摘要
Background: Ultra-low-dose (ULD) computed tomography (CT) scans should be used when CT is performed only for attenuation correction (AC) of positron emission tomography (PET) data. A tin filter can be used in addition to the standard aluminium bowtie filter to reduce CT radiation dose to patients. The aim was to determine how low CT doses can be, when utilised for PET AC, with and without the tin filter, whilst providing adequate PET quantification. Methods: A water-filled NEMA image quality phantom was imaged in three configurations with 18F-FDG: (1) water only (0HU); (2) with cylindrical insert containing homogenous mix of sand, flour and water (SFW, approximately 475HU); (3) with cylindrical insert containing sand (approximately 1100HU). Each underwent one-bed-position (26.3 cm) PET-CT comprising 1 PET and 13 CT acquisitions. CT acquisitions with tube current modulation were performed at 120 kV/50 mAs-ref (reference standard), 100 kV/7 mAs-ref (standard ULDCT for PET AC protocol), Sn140kV (mAs range 7–50-ref) and Sn100kV (mAs range 12–400-ref). PET data were reconstructed with μ-maps provided by each CT dataset, and PET activity concentration measured in each reconstruction. Differences in CT dose length product (DLP) and PET quantification were determined relative to the reference standard. Results: At each tube voltage, changes in PET quantification were greater with increasing density and reducing mAs. Compared with the reference standard, differences in PET quantification for the standard ULDCT protocol for the three phantoms were ≤ 1.7%, with the water phantom providing a DLP of 7mGy.cm. With tin filter at Sn100kV, differences in PET quantification were negligible (≤ 1.2%) for all phantoms down to 50mAs-ref, proving a DLP of 2.8mGy.cm, at 60% dose reduction compared with standard ULDCT protocol. Below 50mAs-ref, differences in PET quantification were > 2% for at least one phantom (2.3% at 25mAs-ref in SFW; 6.4% at 12mAs-ref in sand). At Sn140kV/7mAs-ref, quantification differences were ≤ 0.6% in water, giving 3.8mGy.cm DLP, but increased to > 2% at bone-equivalent densities. Conclusions: CT protocols for PET AC can provide ultra-low doses with adequate PET quantification. The tin filter can allow 60–87% lower dose than the standard ULDCT protocol for PET AC, depending on tissue density and accepted change in PET quantification. © 2023, Springer Nature Switzerland AG.
引用
收藏
相关论文
共 50 条
  • [1] Ultra-low Dose CT With and Without Tin Filter for PET Attenuation Correction: Dose Savings and Quantification
    Bebbington, N.
    Christensen, K. B.
    Ostergard, L. L.
    Holdgaard, P. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S227 - S228
  • [2] Evaluation of ultra-low-dose CT with tin filter for craniosynostosis
    Tao, Wilson
    Goetti, Robert
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2025, 69 (01) : 28 - 34
  • [3] Evaluation of PET attenuation correction accuracy with ultra-low-dose CT on the Vereos digital PET/CT scanner
    Narayanan, Manoj
    Miller, Michael
    Tung, Chi-hua
    Omer, Simon
    McFarland, Michael
    Hubenschmidt, James
    Natarajamani, Deepa
    Hu, Zhiqiang
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [4] Ultra Low Dose CT for Attenuation Correction in PET/CT
    Colsher, James G.
    Hsieh, Jiang
    Thibault, Jean-Baptiste
    Lonn, Albert
    Pan, Tinsu
    Lokitz, Stephen J.
    Turkington, Timothy G.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4779 - +
  • [5] Ultra-low Dose CT for PET Attenuation Correction
    Prieto, E.
    Aguilar, B.
    Moran, V.
    Perez-Macho, M.
    Castellet-Garcia, C.
    Marti-Climent, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S838 - S838
  • [6] Ultra-low dose CT attenuation correction for PET/CT
    Xia, Ting
    Alessio, Adam
    De Man, Bruno
    Manjeshwar, Ravindra
    Asma, Evren
    Kinahan, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [7] Ultra-low dose CT attenuation correction for PET/CT
    Xia, Ting
    Alessio, Adam M.
    De Man, Bruno
    Manjeshwar, Ravindra
    Asma, Evren
    Kinahan, Paul E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02): : 309 - 328
  • [8] Limits of Ultra-Low Dose CT Attenuation Correction for PET/CT
    Xia, Ting
    Alessio, Adam M.
    Kinahan, Paul E.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3074 - 3079
  • [9] Ultra low-dose CT attenuation correction in PET SPM
    Wang, Shyh-Jen
    Yang, Bang-Hung
    Tsai, Chia-Jung
    Yang, Ching-Ching
    Lee, Jason J. S.
    Wu, Tung-Hsin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 397 - 400
  • [10] Optimization of low dose CT based attenuation correction for brain PET/CT protocols
    Kim, Jung Sun
    Kim, Ho Sung
    Ryu, Jae Kwang
    Jung, Woo Young
    Dong, Kyeong Rae
    Chung, Woon Kwan
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55