Experience in using recorders of synchronized current and voltage measurements on 110 kV overhead power lines

被引:0
|
作者
Krasnyshov S.V. [1 ]
Manzhelii M.I. [1 ]
Lachugin V.F. [2 ]
Sidoruk S.V. [2 ]
Dzhangirov V.A. [2 ]
Boyarkin I.E. [3 ]
机构
[1] JSC ASK Ékspress, Moscow
[2] JSCG. M. Krzhizhanovskii Power Institute, Moscow
[3] JSC IDGC of Volga- Orenburgénergo, Moscow
关键词
diagnostics; fault location determination; oil-filled circuit breakers; overhead lines; synchronized measurements; transients;
D O I
10.1007/s10749-011-0213-9
中图分类号
学科分类号
摘要
The results of an investigation of the functioning of recorders of synchronized measurements of electromagnetic transients on the Pugachi - Akbulak 110 kV overhead transmission lines (a branch of the JSC "IDGC of Volga" - "Orenburgénergo") when checking the technical characteristics of oil-filled circuit breakers and when determining the location of a fault on the line by the wave method of bilateral measurements are presented. © 2011 Springer Science+Business Media, Inc.
引用
收藏
页码:492 / 497
页数:5
相关论文
共 50 条
  • [1] Concept of sacrificial arresters for the parallel conduct of 110-KV traction current overhead lines and 380 KV overhead lines
    Opferableiterkonzept für die Parallelführung von 110-kV-Bahnstromleitungen und 380-kV-Freileitungen
    Westenthanner, Matthias (matthias.westenthanner@deutschebahn.com), 1600, DIV Deutscher Industrieverlag GmbH (114):
  • [2] Accurate fault location in three-terminal overhead lines using two-end synchronized measurements of voltage and current phasors
    Izykowski, Jan
    Bozek, Marcin
    MolĄg, Rapal
    Archives of Electrical Engineering, 2007, 56 (221-222): : 213 - 228
  • [3] The assessment of the appropriateness of 110 kV overhead lines
    Dvorsky, Emil
    Hejtmankova, Pavla
    PROCEEDINGS OF THE 14TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2013, 2013, : 449 - 453
  • [4] Computation of the Magnetic Field Exposure from 110 kV Overhead Power Lines
    Lunca, Eduard
    Istrate, Marcel
    Salceanu, Alexandru
    Tibuliac, Stefan
    PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2012), 2012, : 628 - 631
  • [5] Voltage tests insulating systems new project overhead lines 110-400 kV
    Mikulski, January Lech
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (05): : 218 - 221
  • [6] CURRENT-CARRYING CAPACITY OF STRANDED CONDUCTORS FOR OVERHEAD LINES IN THE RANGE BETWEEN 1 KV AND 110 KV
    KUHNE, G
    ENERGIETECHNIK, 1982, 32 (09): : 345 - 350
  • [7] RADIO NOISE MEASUREMENTS ON OVERHEAD POWER LINES FROM 2.4 TO 800 KV
    PAKALA, WE
    CHARTIER, VL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (03): : 1155 - &
  • [8] Estimation of Power Exchange through 110 kV Overhead Power Lines at the Interface of the Romanian and Moldovan Power Systems
    Postolaty, V
    Berzan, V
    Bykova, E.
    Bosneaga, V
    Suslov, V
    Ermurachi, Iu
    Gh, Grigoras
    Gavrilas, M.
    Istrate, M.
    PROBLEMELE ENERGETICII REGIONALE, 2018, (02): : 46 - 61
  • [9] Technological Violations on Overhead Lines with Voltage of 10 Kv
    Ershov, Aleksandr M.
    Khlopova, Anna, V
    Sidorov, Aleksandr, I
    2020 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2020,
  • [10] Current-Carrying Capacity of Stranded Conductors for Overhead Lines in the Range Between 1 kV and 110 kV.
    Kuehne, Guenter
    Energietechnik Leipzig, 1982, 32 (09): : 345 - 350