Effect of scanner lens on lateral response artefact in radiochromic film dosimetry

被引:0
|
作者
Tarafder Shameem
Nick Bennie
Martin Butson
David Thwaites
机构
[1] North Coast Cancer Institute,Institute of Medical Physics, School of Physics
[2] University of Sydney,undefined
[3] EPA,undefined
关键词
Radiotherapy dosimetry; Radiochromic film; Gafchromic; Epson scanner; Film dosimetry; Lens effect;
D O I
暂无
中图分类号
学科分类号
摘要
Radiochromic film is a good dosimeter choice for patient QA for complex treatment techniques because of its near tissue equivalency, high spatial resolution and established method of use. Commercial scanners are typically used for film dosimetry, with Epson scanners being the most common. Radiochromic film dosimetry is not straightforward having some well-defined problems which must be considered, one of the main ones being the Lateral Response Artefact (LRA) effect. Previous studies showed that the contributing factors to LRA are from the structure of the active ingredients of the film and the components and construction of the flatbed scanner. This study investigated the effect of the scanner lens on the LRA effect, as part of a wider investigation of scanner design effects and uncertainties. Gafchromic EBT3 films were irradiated with 40 × 40 cm2 field size 6 MV beams. Films were analysed using images captured by a Canon 7D camera utilising 18 mm, 50 mm and 100 mm focal length lenses compared to images scanned with a conventional Epson V700 scanner. The magnitude of the LRA was observed to be dependent on the focal length of the lens used to image the film. A substantial reduction in LRA was seen with the use of the 50 mm and 100 mm lenses, by factors of 3–5 for the 50 mm lens and 4–30 for the 100 mm lens compared to conventional desktop scanner techniques. This is expected to be from the longer focal length camera lens system being able to collect more light from distant areas compared to the scanner-based system. This provides an opportunity to design film dosimetry systems that minimise this artefact.
引用
收藏
页码:721 / 727
页数:6
相关论文
共 50 条
  • [21] Precise radiochromic film dosimetry using a flat-bed document scanner
    Devic, S
    Seuntjens, J
    Sham, E
    Podgorsak, EB
    Schmidtlein, CR
    Kirov, AS
    Soares, CG
    MEDICAL PHYSICS, 2005, 32 (07) : 2245 - 2253
  • [22] Impact of Document Scanner Resolution on Raw Signal Noise in Radiochromic Film Dosimetry
    Devic, S.
    Tomic, N.
    Aldelaijan, S.
    Seuntjens, J.
    Moftah, B.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S695 - S696
  • [23] LINEARIZATION OF THE RADIOCHROMIC FILM DOSIMETRY SYSTEM DOSE RESPONSE
    Tomic, Nada
    Seuntjens, Jan
    DeBlois, Francois
    Devic, Slobodan
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S9 - S10
  • [24] RADIOCHROMIC FILM DOSIMETRY USING A COMMERCIAL FLATBED DOCUMENT SCANNER: A FEASIBILITY STUDY
    Adamczyk, S.
    Litoborski, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S216 - S216
  • [25] Optimal response function for radiochromic film dosimetry system
    Devic, S.
    Aldelaijan, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [26] Temperature Effect During Radiation Exposure Period for Radiochromic Film Dosimetry Using Flatbed Scanner Densitometer
    Ren, T.
    Bourland, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E608 - E608
  • [27] Multichannel Normalized Pixel Value as a Response Function for Radiochromic Film Dosimetry Enables Simultaneous Dose Response Linearization and Scanner Response Correction
    Aldelaijan, S.
    Papaconstadopoulos, P.
    Bekerat, H.
    Khosravi, M.
    Bhagwat, M.
    Seuntjens, J.
    Devic, S.
    Buzurovic, I.
    MEDICAL PHYSICS, 2019, 46 (06) : E413 - E413
  • [28] A Simple Method for Quantifying and Reducing Lateral Response Artifact of Flatbed Scanner for Film Dosimetry
    Du, X.
    Rasmussen, B.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [29] Radiochromic Film Dosimetry Update
    Niroomand-Rad, A.
    Chiu-Tsao, S.
    Trichter, S.
    Das, I.
    MEDICAL PHYSICS, 2015, 42 (06) : 3626 - 3626
  • [30] Eigencolor radiochromic film dosimetry
    Bouchard, Hugo
    Billas, Ilias
    Subiel, Anna
    Duane, Simon
    MEDICAL PHYSICS, 2021, 48 (05) : 2592 - 2603