Cyclic shear tests on RC precast beam-to-column connections retrofitted with a three-hinged steel device

被引:0
|
作者
Gennaro Magliulo
Maddalena Cimmino
Marianna Ercolino
Gaetano Manfredi
机构
[1] University of Naples Federico II,Department of Structures for Engineering and Architecture
[2] University of Naples Federico II,Construction Technologies Institute URT Naples, National Research Council of Italy, DiSt
[3] University of Greenwich,Department of Engineering Science
来源
关键词
RC precast buildings; Beam-to-column connections; Cyclic shear tests; Seismic retrofitting; Three-hinged steel system;
D O I
暂无
中图分类号
学科分类号
摘要
Recent European earthquakes demonstrated that the seismic response of RC precast structures can be significantly influenced by the connection systems. Moreover, during past seismic events, many failures of the beam-to-column connections occurred due to their inadequate strength under seismic loads. The seismic safety of these connections has a crucial role in the overall seismic capacity of existing precast structures. A new connection system is employed as a retrofitting solution for a damaged beam-to-column connection and its cyclic shear performance is investigated by means of two cyclic shear tests on two different configurations. In both the experimental tests, the results demonstrate an efficient behavior of the retrofitted connections under horizontal cyclic loads. The comparison between the performance of the investigated connection and the response of a typical beam-to-column dowel connection allows to discuss the main critical features of the dowel connection system.
引用
收藏
页码:3797 / 3817
页数:20
相关论文
共 50 条
  • [21] Evaluation of shear lag parameters for beam-to-column connections in steel piers
    Hwang, WS
    Kim, YP
    Park, YM
    STRUCTURAL ENGINEERING AND MECHANICS, 2004, 17 (05) : 691 - 706
  • [22] Assessment of Perforated Steel Beam-to-Column Connections Subjected to Cyclic Loading
    Tsavdaridis, Konstantinos Daniel
    Faghih, Faezeh
    Nikitas, Nikolaos
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (08) : 1302 - 1325
  • [23] Cyclic behaviour of steel beam-to-column connections: Interpretation of experimental results
    Calado, L
    De Matteis, G
    Landolfo, R
    Mazzolani, FM
    STABILITY AND DUCTILITY OF STEEL STRUCTURES, 1999, : 211 - 220
  • [24] Cyclic-loading performance of steel beam-to-column moment connections
    Song, Z.S.
    Gu, Q.
    Guo, B.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2001, 22 (01):
  • [25] Development and testing of hybrid precast concrete beam-to-column connections under cyclic loading
    Ghayeb, Haider Hamad
    Razak, Hashim Abdul
    Sulong, N. H. Ramli
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 151 : 258 - 278
  • [26] RC Beam-Column Connections Retrofitted by Steel Prop: Experimental and Analytical Studies
    Kheyroddin, Ali
    Emami, Ebrahim
    Khalili, Ali
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2020, 18 (5A) : 501 - 518
  • [27] Size effect tests on shear failure of interior RC beam-to-column joints under monotonic and cyclic loadings
    Jin, Liu
    Miao, Liyue
    Han, Junyan
    Du, Xiuli
    Wei, Na
    Li, Dong
    ENGINEERING STRUCTURES, 2018, 175 : 591 - 604
  • [28] Large scale tests on composite beam-to-column connections under cyclic loading
    Calado, L
    De Luca, A
    Mele, E
    Pucinotti, R
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 1233 - 1241
  • [29] Damage behavior of steel beam-to-column connections under inelastic cyclic loading
    Liu, Xi-yue
    Wang, Yuan-qing
    Xiong, Jun
    Shi, Yong-jiu
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2017, 18 (11): : 910 - 926
  • [30] Cyclic behavior of steel beam-to-column connections with novel strengthened angle components
    Kang, Lan
    Zhang, Cheng
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (06): : 791 - 804