摘要
Non-rigid image registration is a prerequisite for many medical image analysis applications such as image fusion of multimodality images and quantitative change analysis of a temporal sequence in computer-aided diagnosis. By establishing the point correspondence of the extracted feature points, it is possible to recover the deformation using nonlinear interpolation methods. However, it may be very difficult to establish such correspondence at an initial stage when confronted with large and complex deformation. In this paper, a mixture of principal axes registration (mPAR) method is proposed to resolve the correspondence problem through a neural computational approach. The novel feature of mPAR is the alignment of two point sets without the need of establishing explicit point correspondence. Instead, it aligns the two point sets by minimizing the relative entropy between their probability distributions resulting in a maximum likelihood estimate of the transformation matrix. The registration process consists of two steps: (1) a finite mixture scheme to establish an improved point correspondence and (2) a multilayer perceptron neural network (MLP) to recover the nonlinear deformation. The neural computation for registration uses a committee machine to obtain a mixture of piece-wise rigid registrations, which gives a reliable point correspondence using multiple extracted objects in a finite mixture scheme. Then the MLP is used to determine the coefficients of a polynomial transform using extracted control points. We have applied our mPAR method to register synthetic data sets, surgical prostate models, and a temporal sequence of mammograms of a single patient. The experimental results show that mPAR not only improves the accuracy of the point correspondence but also results in a desirable error-resilience property for control point selection errors.
引用
收藏
页码:237 / 246
页数:9
相关论文
共 50 条
  • [31] Modelling tumour growth patterns with non-rigid image registration
    Mang, Andreas
    Crum, William R.
    Camara, Oscar
    Schnabel, Julia A.
    Caseiras, Gisele Brasil
    Buzug, Thorsten M.
    Jaeger, Hans R.
    Yousry, Tarek A.
    Hawkes, David J.
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 139 - +
  • [32] Introduction to the non-rigid image registration evaluation project (NIREP)
    Christensen, Gary E.
    Geng, Xiujuan
    Kuhl, Jon G.
    Bruss, Joel
    Grabowski, Thomas J.
    Pirwani, Imran A.
    Vannier, Michael W.
    Allen, John S.
    Damasio, Hanna
    BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS, 2006, 4057 : 128 - 135
  • [33] Fast fluid registration using inverse filtering for non-rigid image registration
    Xu, Xiaoyan
    Dony, Robert D.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 470 - +
  • [34] Non-rigid Image Registration based on the Globally Optimized Correspondences
    Il Koo, Hyung
    Kuk, Jung Gap
    Cho, Nam Ik
    19TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1-6, 2008, : 1506 - 1509
  • [35] Feature-Driven Direct Non-Rigid Image Registration
    Brunet, Florent
    Gay-Bellile, Vincent
    Bartoli, Adrien
    Navab, Nassir
    Malgouyres, Remy
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2011, 93 (01) : 33 - 52
  • [36] ANHIR: Automatic Non-Rigid Histological Image Registration Challenge
    Borovec, Jiri
    Kybic, Jan
    Arganda-Carreras, Ignacio
    Sorokin, Dmitry V.
    Bueno, Gloria
    Khvostikov, Alexander V.
    Bakas, Spyridon
    Chang, Eric I-Chao
    Heldmann, Stefan
    Kartasalo, Kimmo
    Latonen, Leena
    Lotz, Johannes
    Noga, Michelle
    Pati, Sarthak
    Punithakumar, Kumaradevan
    Ruusuvuori, Pekka
    Skalski, Andrzej
    Tahmasebi, Nazanin
    Valkonen, Masi
    Venet, Ludovic
    Wang, Yizhe
    Weiss, Nick
    Wodzinski, Marek
    Xiang, Yu
    Xu, Yan
    Yan, Yan
    Yushkevich, Paul
    Zhao, Shengyu
    Munoz-Barrutia, Arrate
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3042 - 3052
  • [37] Feature-Driven Direct Non-Rigid Image Registration
    Florent Brunet
    Vincent Gay-Bellile
    Adrien Bartoli
    Nassir Navab
    Rémy Malgouyres
    International Journal of Computer Vision, 2011, 93 : 33 - 52
  • [38] Iterative Non-rigid Image Registration Based on Mobius Transformations
    Gerganov, Georgi V.
    Mitev, Krasimir K.
    Kawrakow, Iwan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2973 - 2975
  • [39] Non-rigid Image Registration with Uniform Spherical Structure Patterns
    Liao, Shu
    Chung, Albert C. S.
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2009, 5636 : 163 - 175
  • [40] Non-rigid multimodal image registration using mutual information
    Gaens, T
    Maes, F
    Vandermeulen, D
    Suetens, P
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 1099 - 1106