Sensitive determination of adenine on poly(amidosulfonic acid)-modified glassy carbon electrode

被引:0
|
作者
Rui Zhang
Gendi Jin
Xiaoya Hu
机构
[1] Yangzhou University,College of Chemistry and Engineering
关键词
Adenine; Poly-ASA-modified GCE; Differential pulse voltammetry; Enhanced sensitivity;
D O I
暂无
中图分类号
学科分类号
摘要
A novel and reliable direct electrochemical method was established for the detection of adenine, based on the differential pulse anodic stripping response at a poly(amidosulfonic acid) (poly-ASA)-modified glassy carbon electrode (GCE) fabricated by electropolymerization. The characterization of electrochemically synthesized poly-ASA film was investigated by atomic force microscopy, electrochemical impedance spectroscopy, and voltammetric methods. This poly-ASA-modified GCE could greatly enhance the detection sensitivity of adenine. At optimum conditions, the anodic peak exhibits a good linear concentration dependence in the range from 3.0 × 10−8 to 1.0 × 10−6 M (r = 0.9994). The detection limit is 8.0 × 10−9 M (S/N = 3). The proposed method could be used to determinate the adenine in tablets of vitamin B4 with satisfactory results.
引用
收藏
页码:1545 / 1552
页数:7
相关论文
共 50 条
  • [21] Electrochemical Determination of Bisphenol A Based on Poly(Chromotropic Acid) Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (06) : 464 - 473
  • [22] Simultaneous Determination of Epinephrine and Uric Acid at Poly (Guanine) Modified Glassy Carbon Electrode
    Li, Hongying
    Wang, Xueliang
    ELECTROCHEMISTRY, 2015, 83 (06) : 434 - 439
  • [23] Simultaneous determination of epinephrine and uric acid at poly (guanine) modified glassy carbon electrode
    Department of Chemistry and Chemical Engineering, Heze University, Daxue Road No.1, Heze
    274015, China
    Electrochem, 1600, 6 (434-439): : 434 - 439
  • [24] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [25] Determination of dopamine in the presence of ascorbic acid using poly(hippuric acid) modified glassy carbon electrode
    Zhao, H
    Zhang, YH
    Yuan, ZB
    ELECTROANALYSIS, 2002, 14 (14) : 1031 - 1034
  • [26] Determination of Acetaminophen in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Poly(Caffeic acid)
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Cetintas, Gamze
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (01): : 148 - 160
  • [27] Poly(para amino benzene sulfonic acid) Modified Glassy Carbon Electrode for the Simultaneous as well as Individual Voltammetric Determination of Guanine, Adenine and Uric Acid
    Jesny, S.
    Kumar, K. Girish
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (14) : B720 - B726
  • [28] A glassy carbon electrode modified with poly(anthranilic acid), poly(diphenylamine sulfonate) and CuO nano-particles for the sensitive determination of hydrogen peroxide
    Haiyan Song
    Yongnian Ni
    Serge Kokot
    Microchimica Acta, 2013, 180 : 1263 - 1270
  • [29] A glassy carbon electrode modified with poly(anthranilic acid), poly(diphenylamine sulfonate) and CuO nano-particles for the sensitive determination of hydrogen peroxide
    Song, Haiyan
    Ni, Yongnian
    Kokot, Serge
    MICROCHIMICA ACTA, 2013, 180 (13-14) : 1263 - 1270
  • [30] Sensitive Determination of Copper on New Modified Glassy Carbon Paste Electrode
    Skrivanj, Sandra
    Stankovic, Dalibor M.
    Khan, Muslim
    Nikolic, Aleksandar S.
    Vulic, Predrag
    Manojlovic, Dragan D.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (02): : 230 - 241